Hélène DEBEDA

Dr. Hélène DEBEDA

University of Bordeaux, IMS Laboratory, 351 Cours de la Libération, 33405 Talence Cedex, France
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2010 in IEEE Sensors Journal
Verified
Journal Article
Closed access
RLRiadh Lakhmi
Riadh Lakhmi
Hélène DEBEDAHélène DEBEDA
Hélène DEBEDA
IDIsabelle Dufour
Isabelle Dufour
CLClaude Lucat
Claude Lucat
In this paper, the design, the fabrication, and the characterization of glass ceramic screen-printed force sensors are described. They are based on the use of cantilevers with integrated piezoresistors. The choice of the materials constituting the cantilever and the strain gauge, so as the dimensions of the cantilever have been optimized in order to measure forces in mN range. The sensors have been fabricated using the screen-printing technique associated with the sacrificial layer technique to release the freestanding part of the cantilevers. Afterwards, they have been characterized: measurement of sensitivity, reproducibility, and materials properties (Young's modulus and strain gauge factor). The performances of these sensors are compared to the existing silicon, polymer, and ceramic sensors.

1 April 1995 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
FMF. Me´nil
F. Me´nil
CLC. Lucat
C. Lucat
Hélène DEBEDAHélène DEBEDA
Hélène DEBEDA

1 June 2008 in Microelectronics Reliability
Verified
Journal Article
Closed access
CLClaude Lucat
Claude Lucat
PGPatrick Ginet
Patrick Ginet
CCChristophe Castille
Christophe Castille
Hélène DEBEDAHélène DEBEDA
Hélène DEBEDA
FMFrancis Ménil
Francis Ménil

1 April 2005 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
FMFrancis Ménil
Francis Ménil
MSMarc Susbielles
Marc Susbielles
Hélène DEBEDAHélène DEBEDA
Hélène DEBEDA
CLClaude Lucat
Claude Lucat
PTPascal Tardy
Pascal Tardy

1 January 1997 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
Hélène DEBEDAHélène DEBEDA
Hélène DEBEDA
PMP Massok
P Massok
CLC Lucat
C Lucat
FMF Ménil
F Ménil
JAJ L Aucouturier
J L Aucouturier
This paper shows the long route between gas-sensitive tin oxide material and a reliable prototype for selective methane sensing. A good reproducibility of fabrication is a prerequisite to any development of a cheap sensing device. Hybrid thick-film technology appears well adapted for this purpose, on the condition that the rheological properties of the pastes are well controlled. Sensitivity was shown to be modified by the thickness of the tin oxide layer, the addition of palladium, the addition of a glass binder, the nature of the electrode metal and the presence of a coating. Methane selectivity was achieved by adapting a concept proposed previously, based on the differential catalytic activity of palladium and platinum versus the oxidation of methane at and by combining two sensing principles on the same alumina substrate. As for long-term stability, much information could be gained by annealing at temperatures higher than that of operation. Metal interdiffusion in the sensor connections (Kirkendall effect) and between the catalysts and the other metallic parts of the sensor was demonstrated to be a major cause of instability. Moreover, the firing and annealing conditions used in the fabrication process of our sensors, including that of the Pt heating resistor, were also shown to influence the reliability.

15 November 2019
Verified
Book Chapter
Closed access
Hélène DEBEDAHélène DEBEDA
Hélène DEBEDA
IDIsabelle Dufour
Isabelle Dufour