Rotator cuff repairs frequently fail due to inadequate biologic healing at the tendon–bone interface. Patch augmentation has emerged as a strategy to enhance this process by promoting cellular infiltration, organized collagen deposition, and matrix remodeling. This review evaluates the histologic and biochemical effects of scaffold augmentation, compares different augmentation materials, and analyzes commercially available implants based on animal and human studies. A Preferred Reporting Items for Systematic reviews and Meta-Analyses–guided search of PubMed, Scopus, and Embase through May 2025 identified 42 eligible studies that reported histologic or biochemical outcomes following augmented rotator cuff repair. Dermal matrix patches demonstrated accelerated early neovascularization and collagen synthesis but were associated with incomplete fibrocartilage formation and persistent type III collagen. Extracellular matrix–derived patches showed improved collagen alignment but were linked to inflammatory responses. Synthetic polymers produced dense type I collagen with variable immune reactions, while biologically augmented scaffolds achieved high collagen density with minimal macrophage infiltration. Demineralized bone matrix demonstrated early fibrocartilage integration, mature collagen crimp, and low inflammatory response by 8 weeks. Among commercially available products, REGENETEN, ArthroFLEX, and Dynagraft II showed the most complete scaffold resorption and tendon-like remodeling, whereas Conexa and Zimmer patches demonstrated consistent integration, and Permacol and BioEnthesis showed limited improvements. Overall, patch augmentation appears to enhance biologic healing after rotator cuff repair; however, definitive conclusions are limited by the lack of high-quality human studies. These findings may inform scaffold selection and future implant design aimed at improving tendon–bone healing and reducing retear rates.
Background: The radiocapitellar articulation of the elbow joint is particularly susceptible to subluxation and dislocation. Joint stability can be quantified using the stability ratio, a biomechanical parameter of joint stability defined as the ratio of the maximum dislocating force the joint can resist in relation to the joint compressive force. The purpose of this study was to biomechanically assess the stability of the radiocapitellar joint in the anterior and posterior direction across varying degrees of elbow flexion. Methods: Eight fresh-frozen cadaveric elbows, average age 68.9 years (range 61–73 years; 3 males and 5 females; 7 left and 1 right) were tested. The distal humerus and proximal radius were dissected of all soft tissues to isolate the radiocapitellar articulation. The radius and humerus were mounted on a custom jig that allows for positional adjustment and incorporates a material testing machine. Each specimen was mounted at neutral forearm position and tested at 30, 45, and 60 degrees of anatomical elbow flexion. All specimens were subjected to 10 mm of anterior–posterior displacement for 5 cycles at 20 mm per minute with 40 N of compressive load. Subluxation force, displacement at subluxation force, linear stiffness, stability ratio, and energy absorbed were calculated. Results: In all degrees of elbow flexion, the stability ratio in the posterior direction was significantly higher than the anterior direction by an average of 39.8 ± 32.6% (p < 0.025). Maximum subluxation force was also significantly higher in the posterior direction when compared to the anterior direction (p < 0.027). There was no significant difference in any other parameters. Conclusions: The stability ratio and maximum subluxation force of the radiocapitellar joint when positioned in neutral forearm rotation are significantly greater in the posterior direction when compared to the anterior direction. This finding provides quantitative insights and a biomechanical rationale for the propensity of anterior instability in the radiocapitellar joint.