Yunxiao Xin

Dr. Yunxiao Xin

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Tunnelling and Underground Space Technology
Verified
Journal Article
Closed access
DZDankun Zhou
Dankun Zhou
XLXiaozhao Li
Xiaozhao Li
QWQi Wang
Qi Wang
RWRui Wang
Rui Wang
TWTianding Wang
Tianding Wang
YXYunxiao Xin
Yunxiao Xin

9 August 2017 in Frontiers of Structural and Civil Engineering
Verified
Journal Article
Closed access
PDF file
YWYaqiong Wang
Yaqiong Wang
YXYunxiao Xin
Yunxiao Xin
YXYongli Xie
Yongli Xie
JLJie Li
Jie Li
ZWZhifeng Wang
Zhifeng Wang

2 November 2021 in Environmental Earth Sciences
Verified
Journal Article
Closed access
PDF file
YXYunxiao Xin
Yunxiao Xin
XLXiaozhao Li
Xiaozhao Li
WZWei Zhang
Wei Zhang
QWQi Wang
Qi Wang

10 July 2024
Verified
Book Chapter
Closed access
PDF file
YXYunxiao Xin
Yunxiao Xin
ZWZhang Wei
Zhang Wei
LXLi Xiaozhao
Li Xiaozhao
MJMa Jiajun
Ma Jiajun
SYShi Yehui
Shi Yehui

25 June 2026 in Tunnelling and Underground Space Technology
Verified
Journal Article
Closed access
YXYunxiao Xin
Yunxiao Xin
YWYaqiong Wang
Yaqiong Wang
BFBinghui Fang
Binghui Fang
CDChun Du
Chun Du

17 March 2021 in Research Square
Verified
Preprint
Open access
PDF file
YXYunxiao Xin
Yunxiao Xin
XLXiaozhao Li
Xiaozhao Li
WZWei Zhang
Wei Zhang
QWQi Wang
Qi Wang
Continuous pumping of groundwater will induce uneven ground settlement, which may adversely affect the nearby metro tunnels. In this paper, taking Nantong Metro Line 1 crossing Nantong Port Water Plant as an example, the surface level measurement and subsurface deformation monitoring using vertically distributed fiber-optic sensing are implemented to acquire the surface and subsurface settlement of emergency water supply conditions. The fiber optic cable vertically buried in the constant-temperature layer is used to measure the subsurface strain field and deduce the deformation amount of each stratum. The monitoring results show that, during the pumping, the deformation of the aquifer and ground surface is linearly compressed with time; after the pumping, the ground surface continues to settle linearly at a slower rate for about 50 days, followed by a slow linear rebound, and the aquifer is logarithmically rebounded. In addition, deep pumping causes the deformation of the aquifers to be much greater than the surface settlement; the surface settlement lags behind the settlement of the aquifer by 1 to 2 months; the surface rebound recovery also exhibits a similar delay. Fitting models were derived to predict the maximum settlement and curvature radius of the site, which indicates that the adverse effects against the metro tunnel are not negligible once the continuous pumping exceeds 15 days. Those insights can be referred by the practitioners for the control of urban subsidence.