Background Postlingually deafened adult cochlear implant (CI) users routinely display large individual differences in the ability to recognize and understand speech, especially in adverse listening conditions. Although individual differences have been linked to several sensory (‘‘bottom-up’') and cognitive (‘‘top-down’') factors, little is currently known about the relative contributions of these factors in high- and low-performing CI users. Purpose The aim of the study was to investigate differences in sensory functioning and neurocognitive functioning between high- and low-performing CI users on the Perceptually Robust English Sentence Test Open-set (PRESTO), a high-variability sentence recognition test containing sentence materials produced by multiple male and female talkers with diverse regional accents. Research Design CI users with accuracy scores in the upper (HiPRESTO) or lower quartiles (LoPRESTO) on PRESTO in quiet completed a battery of behavioral tasks designed to assess spectral resolution and neurocognitive functioning. Study Sample Twenty-one postlingually deafened adult CI users, with 11 HiPRESTO and 10 LoPRESTO participants. Data Collection and Analysis A discriminant analysis was carried out to determine the extent to which measures of spectral resolution and neurocognitive functioning discriminate HiPRESTO and LoPRESTO CI users. Auditory spectral resolution was measured using the Spectral-Temporally Modulated Ripple Test (SMRT). Neurocognitive functioning was assessed with visual measures of working memory (digit span), inhibitory control (Stroop), speed of lexical/phonological access (Test of Word Reading Efficiency), and nonverbal reasoning (Raven's Progressive Matrices). Results HiPRESTO and LoPRESTO CI users were discriminated primarily by performance on the SMRT and secondarily by the Raven's test. No other neurocognitive measures contributed substantially to the discriminant function. Conclusions High- and low-performing CI users differed by spectral resolution and, to a lesser extent, nonverbal reasoning. These findings suggest that the extreme groups are determined by global factors of richness of sensory information and domain-general, nonverbal intelligence, rather than specific neurocognitive processing operations related to speech perception and spoken word recognition. Thus, although both bottom-up and top-down information contribute to speech recognition performance, low-performing CI users may not be sufficiently able to rely on neurocognitive skills specific to speech recognition to enhance processing of spectrally degraded input in adverse conditions involving high talker variability.
25 January 2021 in Journal of Speech, Language, and Hearing Research
Purpose: This preliminary research examined (a) the perception of two common sources of indexical variability in speech—regional dialects and foreign accents, and (b) the relation between indexical processing and sentence recognition among prelingually deaf, long-term cochlear implant (CI) users and normal-hearing (NH) peers. Method: Forty-three prelingually deaf adolescent and adult CI users and 44 NH peers completed a regional dialect categorization task, which consisted of identifying the region of origin of an unfamiliar talker from six dialect regions of the United States. They also completed an intelligibility rating task, which consisted of rating the intelligibility of short sentences produced by native and nonnative (foreign-accented) speakers of American English on a scale from 1 ( not intelligible at all ) to 7 ( very intelligible ). Individual performance was compared to demographic factors and sentence recognition scores. Results: Both CI and NH groups demonstrated difficulty with regional dialect categorization, but NH listeners significantly outperformed the CI users. In the intelligibility rating task, both CI and NH listeners rated foreign-accented sentences as less intelligible than native sentences; however, CI users perceived smaller differences in intelligibility between native and foreign-accented sentences. Sensitivity to accent differences was related to sentence recognition accuracy in CI users. Conclusions: Prelingually deaf, long-term CI users are sensitive to accent variability in speech, but less so than NH peers. Additionally, individual differences in CI users' sensitivity to indexical variability was related to sentence recognition abilities, suggesting a common source of difficulty in the perception and encoding of fine acoustic–phonetic details in speech.
17 March 2021 in Journal of Speech, Language, and Hearing Research
Purpose: Cognitive screening tools to identify patients at risk for cognitive deficits are frequently used by clinicians who work with aging populations in hearing health care. Although some studies show improvements in performance on cognitive screening exams when hearing loss intervention is provided in the form of a hearing aid or cochlear implant (CI), it is worth examining whether these improvements are attributable to increased auditory access to test items. This study aimed to examine whether performance and pass rate on a cognitive screening measure, the Montréal Cognitive Assessment (MoCA), improve as a result of CI, whether improved performance on auditory-based test items drives changes in MoCA performance, and whether postoperative MoCA performance relates to post-CI speech perception ability.Method: Data were collected in adult CI candidates pre-implantation and 6 months postimplantation to examine the effect of intervention on MoCA performance. Participants were 77 CI users between the ages of 55 and 85 years. Participants completed the MoCA, administered audiovisually, and speech perception testing with monosyllabic (CNC) words at both intervals.Results: Compared to 31 participants pre-operatively, 45 participants passed the MoCA postoperatively, which was a significant difference in pass rate. An improvement in MoCA scores could be attributed primarily to improvement in the “Delayed Recall” test domain, which was auditory based. Post-CI MoCA performance was related to post-CI CNC speech perception performance.Conclusions: Improved performance and pass rates were demonstrated on the traditional MoCA test of cognitive screening from before to 6 months after CI. Improvements could primarily be attributed to better performance on a delayed recall task dependent on auditory access, and post-CI MoCA scores were related to post-CI speech perception abilities. Further studies are needed to investigate the application of cognitive screening tools in patients receiving hearing loss interventions, and these interventions' impact on patients' real-world functioning.
Hypothesis: This study tested the hypotheses that 1) experienced adult cochlear implants (CI) users demonstrate poorer reading efficiency relative to normal-hearing controls, 2) reading efficiency reflects basic, underlying neurocognitive skills, and 3) reading efficiency relates to speech recognition outcomes in CI users. Background: Weak phonological processing skills have been associated with poor speech recognition outcomes in postlingually deaf adult CI users. Phonological processing can be captured in nonauditory measures of reading efficiency, which may have wide use in patients with hearing loss. This study examined reading efficiency in adults CI users, and its relation to speech recognition outcomes. Methods: Forty-eight experienced, postlingually deaf adult CI users (ECIs) and 43 older age-matched peers with age-normal hearing (ONHs) completed the Test of Word Reading Efficiency (TOWRE-2), which measures word and nonword reading efficiency. Participants also completed a battery of nonauditory neurocognitive measures and auditory sentence recognition tasks. Results: ECIs and ONHs did not differ in word (ECIs: M = 78.2, SD = 11.4; ONHs: M = 83.3, SD = 10.2) or nonword reading efficiency (ECIs: M = 42.0, SD = 11.2; ONHs: M = 43.7, SD = 10.3). For ECIs, both scores were related to untimed word reading with moderate to strong effect sizes (r = 0.43–0.69), but demonstrated differing relations with other nonauditory neurocognitive measures with weak to moderate effect sizes (word: r = 0.11–0.44; nonword: r = (−)0.15 to (−)0.42). Word reading efficiency was moderately related to sentence recognition outcomes in ECIs (r = 0.36–0.40). Conclusion: Findings suggest that postlingually deaf adult CI users demonstrate neither impaired word nor nonword reading efficiency, and these measures reflect different underlying mechanisms involved in language processing. The relation between sentence recognition and word reading efficiency, a measure of lexical access speed, suggests that this measure may be useful for explaining outcome variability in adult CI users.
1 January 2020 in The Journal of the Acoustical Society of America
The current study examined sentence recognition across speaking styles (conversational, neutral, and clear) in quiet and multi-talker babble (MTB) for cochlear implant (CI) users and normal-hearing listeners under CI simulations. Listeners demonstrated poorer recognition accuracy in MTB than in quiet, but were relatively more accurate with clear speech overall. Within CI users, higher-performing participants were also more accurate in MTB when listening to clear speech. Lower performing users' accuracy was not impacted by speaking style. Clear speech may facilitate recognition in MTB for high-performing users, who may be better able to take advantage of clear speech cues.
12 January 2023 in Journal of Speech, Language, and Hearing Research
Purpose: When listening to speech under adverse conditions, older adults, even with “age-normal” hearing, face challenges that may lead to poorer speech recognition than their younger peers. Older listeners generally demonstrate poorer suprathreshold auditory processing along with aging-related declines in neurocognitive functioning that may impair their ability to compensate using “top-down” cognitive–linguistic functions. This study explored top-down processing in older and younger adult listeners, specifically the use of semantic context during noise-vocoded sentence recognition. Method: Eighty-four adults with age-normal hearing (45 young normal-hearing [YNH] and 39 older normal-hearing [ONH] adults) participated. Participants were tested for recognition accuracy for two sets of noise-vocoded sentence materials: one that was semantically meaningful and the other that was syntactically appropriate but semantically anomalous. Participants were also tested for hearing ability and for neurocognitive functioning to assess working memory capacity, speed of lexical access, inhibitory control, and nonverbal fluid reasoning, as well as vocabulary knowledge. Results: The ONH and YNH listeners made use of semantic context to a similar extent. Nonverbal reasoning predicted recognition of both meaningful and anomalous sentences, whereas pure-tone average contributed additionally to anomalous sentence recognition. None of the hearing, neurocognitive, or language measures significantly predicted the amount of context gain, computed as the difference score between meaningful and anomalous sentence recognition. However, exploratory cluster analyses demonstrated four listener profiles and suggested that individuals may vary in the strategies used to recognize speech under adverse listening conditions. Conclusions: Older and younger listeners made use of sentence context to similar degrees. Nonverbal reasoning was found to be a contributor to noise-vocoded sentence recognition. However, different listeners may approach the problem of recognizing meaningful speech under adverse conditions using different strategies based on their hearing, neurocognitive, and language profiles. These findings provide support for the complexity of bottom-up and top-down interactions during speech recognition under adverse listening conditions.