Oleksandra Ivashchenko

Dr. Oleksandra Ivashchenko

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2020 in npj Precision Oncology
Verified
Journal Article
Open access
PDF file
EKEsther N. D. Kok
Esther N. D. Kok
RERoeland Eppenga
Roeland Eppenga
KKKoert F. D. Kuhlmann
Koert F. D. Kuhlmann
HGHarald Groen
Harald Groen
RVRuben van Veen
Ruben van Veen
TRTheo J. M. Ruers
Theo J. M. Ruers
In the past decades, image-guided surgery has evolved rapidly. In procedures with a relatively fixed target area, like neurosurgery and orthopedics, this has led to improved patient outcomes. In cancer surgery, intraoperative guidance could be of great benefit to secure radical resection margins since residual disease is associated with local recurrence and poor survival. However, most tumor lesions are mobile with a constantly changing position. Here, we present an innovative technique for real-time tumor tracking in cancer surgery. In this study, we evaluated the feasibility of real-time tumor tracking during rectal cancer surgery. The application of real-time tumor tracking using an intraoperative navigation system is feasible and safe with a high median target registration accuracy of 3 mm. This technique allows oncological surgeons to obtain real-time accurate information on tumor location, as well as critical anatomical information. This study demonstrates that real-time tumor tracking is feasible and could potentially decrease positive resection margins and improve patient outcome.

12 February 2015 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
OIOleksandra Ivashchenko
Oleksandra Ivashchenko
FHFrans van der Have
Frans van der Have
MGMarlies C. Goorden
Marlies C. Goorden
RRRuud M. Ramakers
Ruud M. Ramakers
FBFreek J. Beekman
Freek J. Beekman
SPECT with submegabecquerel amounts of tracer or subsecond time resolution would enable a wide range of new imaging protocols such as screening tracers with initially low yield or labeling efficiency, imaging low receptor densities, or even performing SPECT outside regular radiation laboratories. To this end we developed dedicated ultra-high-sensitivity pinhole SPECT. Methods: A cylindric collimator with 54 focused 2.0-mm-diameter conical pinholes was manufactured and mounted in a stationary small-animal SPECT system. The system matrix for image reconstruction was calculated via a hybrid method based on both 99mTc point source measurements and ray-tracing analytic modeling. SPECT images were reconstructed using pixel-based ordered-subsets expectation maximization. Performance was evaluated with phantoms and low-dose bone, dynamic kidney, and cardiac mouse scans. Results: The peak sensitivity reached 1.3% (13,080 cps/MBq). The reconstructed spatial resolution (rod visibility in a micro-Jaszczak phantom) was 0.85 mm. Even with only a quarter megabecquerel of activity, 30-min bone SPECT scans provided surprisingly high levels of detail. Dynamic dual-isotope kidney and 99mTc-sestamibi cardiac scans were acquired with a time-frame resolution down to 1 s. Conclusion: The high sensitivity achieved increases the range of mouse SPECT applications by enabling in vivo imaging with less than a megabecquerel of tracer activity or down to 1-s frame dynamics.

5 December 2023 in Physica Medica
Verified
Journal Article
Open access
OIOleksandra Ivashchenko
Oleksandra Ivashchenko
JOJim O'DOherty
Jim O'DOherty
DHDeni Hardiansyah
Deni Hardiansyah
MCMarta Cremonesi
Marta Cremonesi
JTJohannes Tran-Gia
Johannes Tran-Gia
Gerhard GlattingGerhard Glatting
Gerhard Glatting
Absorbed radiation doses are essential in assessing the effects, e.g. safety and efficacy, of radiopharmaceutical therapy (RPT). Patient-specific absorbed dose calculations in the target or the organ at risk require multiple inputs. These include the number of disintegrations in the organ, i.e. the time-integrated activities (TIAs) of the organs, as well as other parameters describing the process of radiation energy deposition in the target tissue (i.e. mean energy per disintegration, radiation dose constants, etc). TIAs are then estimated by incorporating the area under the radiopharmaceutical's time-activity curve (TAC), which can be obtained by quantitative measurements of the biokinetics in the patient (typically based on imaging data such as planar scintigraphy, SPECT/CT, PET/CT, or blood and urine samples). The process of TAC determination/calculation for RPT generally depends on the user, e.g., the chosen number and schedule of measured time points, the selection of the fit function, the error model for the data and the fit algorithm. These decisions can strongly affect the final TIA values and thus the accuracy of calculated absorbed doses. Despite the high clinical importance of the TIA values, there is currently no consensus on processing time-activity data or even a clear understanding of the influence of uncertainties and variations in personalised RPT dosimetry related to user-dependent TAC calculation. As a first step towards minimising site-dependent variability in RPT dosimetry, this work provides an overview of quality assurance and uncertainty management considerations of the TIA estimation.

1 January 2015 in Molecular Imaging
Verified
Journal Article
Open access
OIOleksandra Ivashchenko
Oleksandra Ivashchenko
FHFrans van der Have
Frans van der Have
JVJose L. Villena
Jose L. Villena
HGHarald C. Groen
Harald C. Groen
RRRuud M. Ramakers
Ruud M. Ramakers
FBFreek J. Beekman
Freek J. Beekman
Limited spatial resolution of preclinical positron emission tomography (PET) and single-photon emission computed tomography (SPECT) has slowed down applications of molecular imaging in small animals. Here we present the latest-generation U-SPECT system (U-SPECT+, MILabs, Utrecht, the Netherlands) enabling radionuclide imaging of mice with quarter-millimeter resolution. The system was equipped with the newest high-resolution collimator with 0.25 mm diameter circular pinholes. It was calibrated with technetium-99 m point source measurements from which the system matrix was calculated. Images were reconstructed using pixel-based ordered subset expectation maximization (OSEM). Various phantoms and mouse SPECT scans were acquired. The reconstructed spatial resolution (the smallest visible capillary diameter in a hot-rod resolution phantom) was 0.25 mm. Knee joint images show tiny structures such as the femur epicondyle sulcus, as well as a clear separation between cortical and trabecular bone structures. In addition, time-activity curves of the lumbar spine illustrated that tracer dynamics in tiny tissue amounts could be measured. U-SPECT+ allows discrimination between molecular concentrations in adjacent volumes of as small as 0.015 mL, which is significantly better than can be imaged by any existing SPECT or PET system. This increase in the level of detail makes it more and more attractive to replace ex vivo methods and allows monitoring biological processes in tiny parts of organs in vivo.

24 December 2018 in Journal of Surgical Oncology
Verified
Journal Article
Closed access
PDF file
Jasper NijkampJasper Nijkamp
Jasper Nijkamp
KKKoert F. D. Kuhlmann
Koert F. D. Kuhlmann
OIOleksandra Ivashchenko
Oleksandra Ivashchenko
BPBas Pouw
Bas Pouw
NHNikie Hoetjes
Nikie Hoetjes
TRTheo J. M. Ruers
Theo J. M. Ruers

1 May 2020 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
OIOleksandra Ivashchenko
Oleksandra Ivashchenko
ERErik-Jan Rijkhorst
Erik-Jan Rijkhorst
LBLeon C. ter Beek
Leon C. ter Beek
NHNikie J. Hoetjes
Nikie J. Hoetjes
BPBas Pouw
Bas Pouw
TRTheo J.M. Ruers
Theo J.M. Ruers