Oxidative treatment of seawater in coastal and shipboard installations is applied to control biofouling and/or minimize the input of noxious or invasive species into the marine environment. This treatment allows a safe and efficient operation of industrial installations and helps to protect human health from infectious diseases and to maintain the biodiversity in the marine environment. On the downside, the application of chemical oxidants generates undesired organic compounds, so-called disinfection by-products (DBPs), which are discharged into the marine environment. This article provides an overview on sources and quantities of DBP inputs, which could serve as basis for hazard analysis for the marine environment, human health and the atmosphere. During oxidation of marine water, mainly brominated DBPs are generated with bromoform (CHBr3) being the major DBP. CHBr3 has been used as an indicator to compare inputs from different sources. Total global annual volumes of treated seawater inputs resulting from cooling processes of coastal power stations, from desalination plants and from ballast water treatment in ships are estimated to be 470-800 × 109 m3, 46 × 109 m3 and 3.5 × 109 m3, respectively. Overall, the total estimated anthropogenic bromoform production and discharge adds up to 13.5-21.8 × 106 kg/a (kg per year) with contributions of 11.8-20.1 × 106 kg/a from cooling water treatment, 0.89 × 106 kg/a from desalination and 0.86 × 106 kg/a from ballast water treatment. This equals approximately 2-6% of the natural bromoform emissions from marine water, which is estimated to be 385-870 × 106 kg/a.
13 June 2019 in Environmental Science & Technology
Shipboard ballast water management systems (BWMS) commonly employ chlorine or other oxidants to treat ballast. Oxidant-based BWMS inject these biocides to meet a concentration threshold or target value that is lethal to most aquatic organisms. Resulting concentrations of total residual oxidant (TRO) may span two orders of magnitude between initial doses (e.g., ~10 mg L−1) and discharged ballast, which must meet discharge limits (e.g., <0.1 mg L−1). Here, we evaluated three TRO instruments (two colorimetric-based and one based on amperometry) that have been integrated into BWMS for use in shipboard applications. Our study quantified accuracy and precision using test waters along a range of temperatures and salinities, using a pipe loop to mimic in-line shipboard operations, where the instruments continuously sample and analyze circulating water. Linear regression analysis compared the instruments to a standard reference method along a range of concentrations relevant to oxidant-based BWMS. In general, measurements from the TRO sensors showed strong linear relationships to the reference method, but slopes of these relationships were significantly <1 in all but one instance. Precision—measured as the coefficient of variation—ranged from 2 to 4%. These initial tests occurred on units shipped directly from the manufacturer, immediately following calibration and quality checks, and in a controlled laboratory environment. Thus, in this context, our evaluations represent a “best-case” outcome. We recommend that laboratory studies (as described here) be paired with endurance trials and in-service monitoring to include tests in a shipboard environment. These trials should evaluate TRO instruments that are integrated with BWMS and functioning under normal ship operations, measuring both high (treated ballast) and low (neutralized discharge) concentrations of TRO. Shipboard trials in concert with frequent calibration checks will reduce the risks of under- or overestimating TRO concentrations, as both outcomes may harm the environment.