Silviane Gomes Rodrigues

Mrs. Silviane Gomes Rodrigues

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2025 in Agriculture
Verified
Journal Article
Open access
PDF file
SRSilviane Gomes Rodrigues
Silviane Gomes Rodrigues
GAGuilherme Sousa Alves
Guilherme Sousa Alves
JCJoão Paulo Arantes Rodrigues da Cunha
João Paulo Arantes Rodrigues da Cunha
Pulse width modulation (PWM) allows for the real-time flow rate adjustment of spray nozzles without changing system pressure, indicating that PWM is a promising technology for improving the quality of pesticide applications. However, its effect on the droplet formation process is not yet fully understood. In this study, the effects of a PWM system on the droplet spectrum and velocity generated by different flat fan hydraulic nozzles were evaluated. The experiment was conducted via a spray simulator to test the impact of PWM technology under various operational conditions and flat fan nozzle types (standard, pre-orifice, and air inclusion). With the aid of a real-time particle analyzer and high-resolution imaging, the following variables were analyzed: volume median diameter (VMD), relative span, droplet velocity, and the percentage of volume composed of droplets with a diameter smaller than 100 µm. Four simulated working speeds (1.1, 1.7, 2.8, and 3.9 m s−1), which were equivalent to four PWM valve duty cycles (35%, 42%, 71%, and 100%), respectively, were evaluated. The PWM system altered the droplet size, generally reducing the VMD in comparison to the conventional system. The relative span was not influenced by the PWM system’s duty cycle, although system activation increased droplet size heterogeneity in some nozzle types. The droplet velocity was generally slower using the PWM system in comparison with the conventional system, but higher duty cycles increased this parameter. Overall, the results of this study suggest that spray patterns are altered by PWM activation, and the traits of this behaviour depend on the spray nozzle type.

1 January 2024 in Ciência Rural
Verified
Journal Article
Open access
PDF file
SRSilviane Gomes Rodrigues
Silviane Gomes Rodrigues
AKAna Lúcia Pereira Kikuti
Ana Lúcia Pereira Kikuti
HKHamilton Kikuti
Hamilton Kikuti
CPCarlos Eduardo Pereira
Carlos Eduardo Pereira
The peach palm (Bactrisgasipaes) is an important alternative for heart-of-palm extraction, showing precocity, rusticity and high tillering. The seeds of this species are considered recalcitrant making storage for long periods and production of seedlings difficulty. This identified a combination of moisture content of peach palm seeds and temperature during storage for longer seed longevity. Seeds with 35% and 45% of moisture content (wet basis - wb) were storage at 20 °C and 25 ºC during 180 days. The evaluations were carried out every 60 days by the germination test, emergence in sand, shoot length, diameter of stem, shoot dry matter, root dry matter and moisture content. It was observed that seeds with moisture content of 45% wb showed better performance during storage. The storage at 20 ºC provides higher seed quality maintenance. Peach palm seeds maintain their viability for 120 days when stored with moisture content of 45% wb at 20 ºC.