Sajad Keshavarz

Dr. Sajad Keshavarz

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2020 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
SDSepideh Yazdani Darki
Sepideh Yazdani Darki
SKSajad Keshavarz
Sajad Keshavarz

10 December 2019 in Nuclear Energy and Technology
Verified
Journal Article
Open access
PDF file
SKSajad Keshavarz
Sajad Keshavarz
DSDariush Sardari
Dariush Sardari
Gold nanoparticles can be used to increase the dose of the tumor due to its high atomic number as well as being free from apparent toxicity. The aim of this study is to evaluate the effect of distribution of gold nanoparticles models, as well as changes in nanoparticle sizes and spectrum of radiation energy along with the effects of nanoparticle penetration into surrounding tissues in dose enhancement factor DEF. Three mathematical models were considered for distribution of gold nanoparticles in the tumor, such as 1-uniform, 2- non-uniform distribution with no penetration margin and 3- non-uniform distribution with penetration margin of 2.7 mm of gold nanoparticles. For this purpose, a cube-shaped water phantom of 50 cm size in each side and a cube with 1 cm side placed at depth of 2 cm below the upper surface of the cubic phantom as the tumor was defined, and then 3 models of nanoparticle distribution were modeled. MCNPX code was used to simulate 3 distribution models. DEF was evaluated for sizes of 20, 25, 30, 50, 70, 90 and 100 nm of gold nanoparticles, and 50, 95, 250 keV and 4 MeV photon energies. In uniform distribution model the maximum DEF was observed at 100 nm and 50 keV being equal to 2.90, in non-uniform distribution with no penetration margin, the maximum DEF was measured at 100 nm and 50 keV being 1.69, and in non-uniform distribution with penetration margin of 2.7 mm, the maximum DEF was measured at 100 nm and 50 keV as 1.38, and the results have been showed that the dose was increased by injecting nanoparticles into the tumor. It is concluded that the highest DEF could be achieved in low energy photons and larger sizes of nanoparticles. Non-uniform distribution of gold nanoparticles can increase the dose and also decrease the DEF in comparison with the uniform distribution. The non-uniform distribution of nanoparticles with penetration margin showed a lower DEF than the non-uniform distribution without any margin and uniform distribution. Meanwhile, utilization of the real X-ray spectrum brought about a smaller DEF in comparison to mono-energetic X-ray photons.

18 November 2024 in Physica Scripta
Verified
Journal Article
Closed access
ESElham Salehi
Elham Salehi
NMNahid Makiabadi
Nahid Makiabadi
SKSajad Keshavarz
Sajad Keshavarz
SGSara Ghanavati
Sara Ghanavati
MKMaziar Khateri
Maziar Khateri
RMroya boodaghi malidarre
roya boodaghi malidarre
The accurate calculation of radiation doses in radiotherapy necessitates precise knowledge of the mass attenuation coefficients ( μ m ) of prosthetic materials. Thus, this study aims to determine the μ m of widely used prosthetic materials through theoretical methods, Monte Carlo (MC) simulation, and the XCOM photon cross-section database for the first time. Calculations were performed for the following medical sources: Pd-103, I-125, Cs -131, Tc-99m, Ba-133, Ir-192, Au-198, Cs-137, Ra-226 and Co-60 with a range of energies between 10 keV and 2 MeV. Outcomes reveal that in all three datasets increasing the energy reduces the μ m values for all provided materials. For instance, this value for MMA and PEG and MCNPX simulations, theoretical calculation, XCOM evaluation varies from 0.41911 to 0.09006 cm2.g−1, 0.39194 to 0.08583 cm2.g−1, 0.39790 to 0.08715 cm2.g−1, and 0.45099 to 0.09029 cm2.g−1, 0.42214 to 0.09050 cm2.g−1, 0.40040 to 0.08090 cm2.g-,1 respectively. Furthermore, for high density prosthetic materials like Steel, Titania, and Zinc oxide, μ m is higher specifically at low energy regions compared to low density prosthetic materials, while increasing the energy from 0.021 to 1.25 MeV, a different scenario is recorded. Moreover, MCNPX results exhibit higher deviations specifically in high energy regions compared to other approaches. However, this approach remains as accurate for prosthetic attenuation evaluation. The results of this study present a detailed classification of a wide range of prosthetic materials in terms of their applications and energy levels, serving as a significant reference for future research.

1 August 2025 in Physica Scripta
Verified
Journal Article
Closed access
SPSina Payandeh
Sina Payandeh
SKSajad Keshavarz
Sajad Keshavarz
RMroya boodaghi malidarre
roya boodaghi malidarre
FYFatemeh Hasanzadeh Yasamani
Fatemeh Hasanzadeh Yasamani
Charged particle therapy, including proton, helium-ion, and carbon-ion modalities, is increasingly utilized for brain tumor treatment due to their superior dose distribution. This study compares the flux and equivalent dose of primary and secondary particles delivered to tumors and healthy tissues using Monte Carlo simulations (MCNP code) with a Snyder head phantom. The equivalent dose delivered to the tumor by carbon-ion therapy was found to be 8.1 times higher than that of helium-ion therapy and 41.8 times higher than that of proton therapy. The equivalent dose to surrounding brain tissues ranged from 15–22 Sv for proton, 100–125 Sv for helium-ion, and 1000–1220 Sv for carbon-ion therapy. The flux of carbon particles in the head and tumor was 0.0068 #/cm2 and 0.0001 #/cm2, respectively, which is negligible compared to proton and helium-ion fluxes. Secondary neutron flux was highest in carbon-ion and helium-ion therapies, raising concerns about secondary cancer risk, while proton therapy showed the lowest secondary particle flux. Lateral dose analysis indicated broader peaks for carbon-ion therapy. In conclusion, although carbon-ion therapy achieves greater tumor dose coverage, proton therapy offers better sparing of healthy tissues and reduced secondary particle production, making it a more precise option for brain tumor radiotherapy.


7 August 2025 in International Journal of Biological-Medical Science and Technology
Verified
Journal Article
Open access
SKSajad Keshavarz
Sajad Keshavarz
ESElham Saeedzadeh
Elham Saeedzadeh
EJElnaz Jenabi
Elnaz Jenabi
DSDariush Sardari
Dariush Sardari
HAHossein Arabi
Hossein Arabi
Diffuse large B-cell lymphoma (DLBCL) is a common and aggressive subtype of non-Hodgkin lymphoma. This study aimed to evaluate the effectiveness of deep learning for automatically segmenting DLBCL lesions in positron emission tomography (PET) images, which is crucial for treatment planning and monitoring. A 2D U-Net convolutional neural network was trained on a dataset of FDG-PET scans from 150 DLBCL patients. The model's performance was evaluated using two key metrics: the Dice similarity coefficient (DSC) and the Jaccard index. The results showed a mean DSC of 0.71 and a mean Jaccard index of 0.62, indicating accurate identification of lymphoma lesions. These findings suggest that deep learning-based automated segmentation holds great potential for accurately detecting and delineating DLBCL lesions, thereby improving the precision and effectiveness of treatment planning and monitoring for affected individuals.