Accidental hydrogen releases from pipelines pose significant risks, particularly with the expanding deployment of hydrogen infrastructure. Despite this, there has been a lack of thorough investigation into hydrogen leakage from pipelines, especially under complex real-world conditions. This study addresses this gap by modeling hydrogen gas dispersion, jet fires, and explosions based on practical scenarios. Various factors influencing accident consequences, such as leak hole size, wind speed, wind direction, and trench presence, were systematically examined. The findings reveal that both hydrogen dispersion distance and jet flame thermal radiation distance increase with leak hole size and wind speed. Specifically, the longest dispersion and radiation distances occur when the wind direction aligns with the trench, which is 110 m where the hydrogen concentration is 4% and 76 m where the radiation is 15.8 kW/m2 in the case of a 325 mm leak hole and wind under 10 m/s. Meanwhile, pipelines lacking trenching exhibit the shortest distances, 0.17 m and 0.98 m, at a hydrogen concentration of 4% and 15.8 kW/m2 radiation with a leak hole size of 3.25 mm and no wind. Moreover, under relatively higher wind speeds, hydrogen concentration stratification occurs. Notably, the low congestion surrounding the pipeline results in an explosion overpressure too low to cause damage; namely, the highest overpressure is 8 kPa but this lasts less than 0.2 s. This comprehensive numerical study of hydrogen pipeline leakage offers valuable quantitative insights, serving as a vital reference for facility siting and design considerations to eliminate the risk of fire incidents.
Cryogenic compressed hydrogen (CcH2) technology combines the advantages of high pressure and low temperature to achieve high hydrogen storage density without liquefying the hydrogen, which has broad application prospects. However, the safety concerns related to cryogenic hydrogen need to be carefully addressed beforehand. In the present work, cryogenic hydrogen jet flames are experimentally investigated for various release pressures and initial temperatures. The flame length and thermal radiation flux were measured for horizontally releasing with nozzle diameters of 0.5–2 mm, temperatures ranging from 93 to 298 K, and initial pressures of 2–10 MPa. The results show that the flame length is dependent on the nozzle diameter, stagnation pressure and temperature. At a given pressure, the flame length, size and total radiant power increase with decreasing temperature, which is attributed to the lower jet flow velocity and higher density of low-temperature hydrogen. The normalized flame length Lf/D is correlated with the pressure ratio and temperature ratio. The correlation can be used to predict the flame length at various hydrogen pressures and temperatures. The normalized flame length of the cryogenic hydrogen jet flame is greater than that of the room-temperature hydrogen jet flame. The radiative heat flux of the flame can be predicted by the mass flow rate of the jet flow.
This paper presents an experimental investigation into shockwave and flame characteristics of compressed hydrogen released through various types of pressure relief devices (PRDs) for which data have not been previously reported. Burst disks and safety valves with different set pressure (P0) of 22–140 MPa were tested. Shockwave intensity/velocity spontaneous ignition/flame behavior was monitored by in-situ pressure/light sensors, respectively. Previous works have mostly focused on burst disks with low P0 (under 10 MPa), leaving safety valves and high-pressure burst disks uninvestigated. It was found that shockwave/spontaneous ignition behavior differs with PRD types. Spontaneous ignition occurs in all burst disk cases, along with an ignition/self-extinguishment/reignition process with relatively low P0, which has not been revealed previously. In contrast, none of the safety valves cause spontaneous ignition, resulting from the absence of shockwave due to lower overpressure values/rise rate during release. This suggests that shockwave formed by sudden release is the most dominant factor in spontaneous ignition. Also, the occurrence of self-extinguishment does not guarantee the absence of jet flame. This work provides a comprehensive database revealing shockwave and flame characteristics of hydrogen released through different PRDs, which offers basic data and theoretical support for the safety and risk assessment of high-pressure hydrogen facilities.
The accurate determination of the potential impact radius is crucial for the design and risk assessment of hydrogen pipelines. The existing methodologies employ a single point source model to estimate radiation and the potential impact radius. However, these approaches overlook the jet fire shape resulting from high-pressure leaks, leading to discrepancies between the calculated values and real-world incidents. This study proposes models that account for both the mass release rate, while considering the pressure drop during hydrogen pipeline leakage, and the radiation, while incorporating the flame shape. The analysis encompasses 60 cases that are representative of hydrogen pipeline scenarios. A simplified model for the potential impact radius is subsequently correlated, and its validity is confirmed through comparison with actual cases. The proposed model for the potential impact radius of hydrogen pipelines serves as a valuable reference for the enhancement of the precision of hydrogen pipeline design and risk assessment.
High-pressure hydrogen storage has become the mainstream technical route for fuel cell vehicles due to its high energy density and favorable economic efficiency, with operating pressures gradually increasing from 35 to 70 MPa. However, the complex shock wave structures formed during high-pressure leakage pose significant challenges to numerical simulation. Existing CFD models based on incompressible assumptions or low Mach number conditions are prone to numerical oscillations, nonconvergence, or even computational failure when dealing with the strong nonlinearity and solution discontinuities induced by intense shock waves. Conventional numerical schemes often face a dilemma: low-dissipation schemes may introduce nonphysical oscillations, whereas high-dissipation schemes tend to excessively smooth shock structures, leading to distorted flow characteristics and reduced prediction accuracy. In this study, a numerical model for high-pressure hydrogen jet diffusion is established by considering the functional relationship between the influence range of shock waves at discontinuities and the time step. Validated through 70-MPa schlieren experiments, the model predicts the Mach disk position with an error of 8.7%. The research indicates that local low-pressure zones as low as 25,000 Pa appearing in the flow field significantly reduce the critical autoignition temperature of hydrogen, and the flammable range is primarily concentrated at the wrinkled edges of the hydrogen cloud and near-wall “air entrapment zone.” These findings provide a quantitative basis for optimizing the placement of leak detection sensors and designing explosion venting solutions.
Ethylene oxide (EO) and ethylene glycol (EG) are important materials in the petrochemical industry. However, EO/EG equipment is prone to fire and explosion accidents, which can have severe consequences. Based on the decision tree theory, a prediction model was developed to assess the consequences of wide-area accidents. 90 leakage scenarios of EO/EG facilities were defined, and these scenarios were simulated using FLACS software. This study utilized 80 sets of gas-phase concentration distribution data generated by FLACS under various leakage scenarios. The data set was divided into 60 samples for training the prediction model and 20 samples for validation. The decision tree prediction model accurately and rapidly predicted EO/EG leakage dispersion over an area exceeding 1 km2, as confirmed by simulation comparisons. The model's prediction accuracy exceeded 90%. This study successfully achieved rapid prediction of EO/EG leakage dispersion patterns and concentration distributions using limited simulation data, providing critical support for risk prevention and control in EO/EG facilities.