This study numerically investigates heat transfer and thermodynamic behavior in twisted square and rectangular air ducts while keeping a constant hydraulic diameter (Dh = 30 mm). Three aspect ratios are considered (AR = 1.00, 0.75, and 0.50). The heated test section (900 mm) is divided into three equal segments, and three pitch patterns are examined: a uniform pitch (400–400–400 mm, P444) and two axial gradients (300–400–500 mm, P345; 500–400–300 mm, P543). All results are compared to a standard reference, the straight square duct (SD-AR1.00), to ensure fair comparisons across all cases with Reynolds numbers between 5000 and 20,000. Among the twisted ducts, the strongest rectangularity combined with the increasing pitch sequence, TSD-AR0.50-P345, provides the best overall balance. Its heat transfer rises from Nu = 39.39 to 88.62, giving Nu/Nu0 = 1.493 → 1.433, while the pressure penalty increases to f/f0 = 1.345 → 1.405. Under cube-root weighting of friction, this case maintains the highest thermal performance factor, TPF = 1.352 at Re = 5000 and TPF = 1.279 at Re = 20,000. Second-law trends support the same ranking: exergy destruction decreases from 12.81 W (baseline) to 8.44 W at Re = 5000 (≈34% reduction) and from 6.54 W to 4.84 W at Re = 20,000 (≈26% reduction). The Bejan number remains high at low Reynolds numbers (≈0.998), indicating heat-transfer irreversibility dominance, but drops at higher Reynolds numbers (≈0.87) as frictional effects become more important. In general, the results show that adding a small axial pitch increase to rectangularity can improve near-wall mixing while reducing losses downstream. This leads to a clear improvement in both first-law performance and exergy-based measures.

15 June 2026 in Eng
Verified
Journal Article
Open access
PDF file
YDYuexiang Du
Yuexiang Du
SLSathaporn Liengsirikul
Sathaporn Liengsirikul
APArnut Phila
Arnut Phila
KWKhwanchit Wongcharee
Khwanchit Wongcharee
MPMonsak Pimsarn
Monsak Pimsarn
Smith EIAMSA-ARDSmith EIAMSA-ARD
Smith EIAMSA-ARD
A computational fluid dynamics (CFD) analysis is conducted to systematically investigate heat transfer enhancement in tubes fitted with grooved twisted tapes and to identify the groove geometry that provides the best thermo-hydraulic performance. Three grooved twisted tape configurations—circular-grooved twisted tapes (CGTT), rectangular-grooved twisted tapes (RGTT), and triangular-grooved twisted tapes (TGTT)—are evaluated and compared with a smooth tube and a conventional twisted tape over a Reynolds number range of 5000–20,000 under isothermal wall conditions. The grooved twisted tapes enhance heat transfer through the combined effects of swirl-induced secondary flows and groove-generated flow disturbances, which intensify turbulent mixing and reduce the thickness of the thermal boundary layer. Compared with the plain tube, the grooved configurations increase the Nusselt number by 1.472–1.98 times while increasing the friction factor by 3.21–3.58 times. Relative to the conventional twisted tape, the grooved designs provide an additional 8.0–12.1% enhancement in heat transfer with only a marginal increase of 0.2–1.5% in friction factor. The thermodynamic analysis indicates that the CGTT configuration exhibits the lowest entropy generation rate and exergy loss throughout the investigated Reynolds number range. In particular, the CGTT achieves a Bejan number of 0.999841 at Re = 5000, demonstrating an excellent balance between heat transfer enhancement and frictional losses. Furthermore, the CGTT attains the highest thermal performance factor (TPF) of 1.294 at Re = 5000 and maintains TPF > 1.0 over the entire Reynolds number range. The overall performance ranking is consistently established as CGTT > TGTT > RGTT based on comprehensive analyses of velocity fields, streamline patterns, turbulent kinetic energy distributions, temperature contours, and thermodynamic characteristics. Although the present study identifies the circular-groove configuration as the optimal design for a twist ratio (y/W) of 3.0, further parametric investigations involving variations in twist ratio, groove dimensions, and groove pitch are required to develop generalized design guidelines.

24 June 2026 in Agriengineering
Verified
Journal Article
Open access
PDF file
TWThiri Shoon Wai
Thiri Shoon Wai
Naoki MaruyamaNaoki Maruyama
Naoki Maruyama
NWNapassawan Wongmongkol
Napassawan Wongmongkol
CCChatchawan Chaichana
Chatchawan Chaichana
Smith EIAMSA-ARDSmith EIAMSA-ARD
Smith EIAMSA-ARD
MHMasafumi Hirota
Masafumi Hirota
Rather than cooling an entire facility, local area cooling—achieved by placing simple-shaped heat exchangers near plants—could be an effective, low-energy climate regulation strategy for agricultural fields in greenhouses. In this study, a comparative analysis was performed for three serpentine-shaped heat exchangers varying in pipe diameter (12.7 and 15.88 mm) and pipe spacing (50 and 100 mm). Their heat transfer performance and air temperature distribution were measured in terms of local area cooling. Local air temperatures below the heat exchanger were also measured, whereas temperatures above the unit served as a reference. Both heat transfer performance and the pressure drop in the heat exchangers were investigated as well. Cooling experiments were conducted with inlet fluid temperatures from −5 to 10 °C and flow rates from 0.3 to 3.0 L/min (Re = 50–1394). The results showed that local air temperature reductions reached approximately 9 °C for the 12.7 mm pipe with 50 mm spacing, 10 °C for the 15.88 mm pipe with 50 mm spacing, and 5 °C for the 15.88 mm pipe with 100 mm spacing. Heat flux for the 15.88 mm pipe was two-thirds lower at a spacing of 50 mm and 1.5 times higher at a spacing of 100 mm compared to the pipes smaller in diameter. Moreover, pressure drops for the large-diameter pipes were about half those of the smaller pipes. The results from this experimental study are expected to contribute to practical greenhouse cooling applications and provide useful guidance for configuration selection for heat exchangers.

26 November 2025 in Eng
Verified
Journal Article
Open access
PDF file
KWK. Wongcharee
K. Wongcharee
TWThiri Shoon Wai
Thiri Shoon Wai
Naoki MaruyamaNaoki Maruyama
Naoki Maruyama
MHM. Hirota
M. Hirota
VCVaresa Chuwattanakul
Varesa Chuwattanakul
Smith EIAMSA-ARDSmith EIAMSA-ARD
Smith EIAMSA-ARD
This study reports on heat transfer augmentation by knitted wire coil turbulators in a fully developed turbulent regime. Four knitted wire coil turbulators with different wire loop number densities (N = 6, 8, 10, and 12 loops per pitch, with 1.0 pitch = 6.8 mm) were tested. Each was made by winding a 0.7 mm copper wire around a 1.0 mm core rod. Experiments were conducted under a constant 600 W/m2 wall heat flux. The flow behaviors observed through a dye injection technique revealed that the wire coil induced secondary flows and developed shear layers, contributing to enhanced heat transfer. Heat transfer improved with increasing wire loop number density. Application of knitted wire coil turbulators increased the Nusselt number (Nu) by 86, 95.4, 103.2, and 109.3% for N = 6, 8, 10, and 12, respectively. This corresponded to increased friction factors (f) by 1.77, 1.97, 2.15, and 2.31 times, respectively. The tube with coils having N = 12 yielded the highest thermal performance index (TPI), 1.4, at a Reynolds number of 5000. The empirical correlations for Nu, f, and TPI showed deviations within ±2.1, ±0.68, and ±2.28%, respectively.

15 December 2025 in Agriengineering
Verified
Journal Article
Open access
PDF file
TWThiri Shoon Wai
Thiri Shoon Wai
Naoki MaruyamaNaoki Maruyama
Naoki Maruyama
NWNapassawan Wongmongkol
Napassawan Wongmongkol
CCChatchawan Chaichana
Chatchawan Chaichana
Smith EIAMSA-ARDSmith EIAMSA-ARD
Smith EIAMSA-ARD
MHMasafumi Hirota
Masafumi Hirota
This study investigates the performance of unit-element heat exchangers. Particularly, it focuses on the characteristics of the local air temperature profiles and heat transfer performance of serpentine copper pipe heat exchangers with different diameters, aiming to identify an effective configuration for greenhouse crop cultivation. The term local air temperature refers to the air temperature near the cultivational crops. Cooling experiments were carried out using serpentine heat exchangers with outer pipe diameters of 12.7 mm and 15.88 mm under varying inlet fluid temperatures (−5 °C to 10 °C) and fluid flow rates (0.3–3.0 L/min). Measurements included local air temperature, inlet and outlet fluid temperatures, pipe surface temperatures, and pressure drop, while relative humidity was monitored by checking water condensation on pipe surfaces. The results showed that the average reduction in local air temperature in the area below the heat exchangers reached up to 9.0 °C for the 12.7 mm diameter pipe and 10 °C for the 15.88 mm diameter pipe. Moreover, the pressure drop with the 15.88 mm exchanger was about half that of the 12.7 mm exchanger. These findings highlight the advantages and disadvantages of each type of heat exchanger. Furthermore, they will be useful in selecting an appropriate heat exchanger for greenhouse farming.