S. Vincent Grasso

Prof. S. Vincent Grasso


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
SMSelma Mtoor
Selma Mtoor
NRNiki Rashidian
Niki Rashidian
NMNouredin Messaoudi
Nouredin Messaoudi
SGS. Vincent Grasso
S. Vincent Grasso
FNFloriane Noel
Floriane Noel
Andrew A. GumbsAndrew A. Gumbs
Andrew A. Gumbs
Background: Multimodal AI integration across genomics, radiomics, and pathomics is rapidly evolving in oncology, but evidence remains heterogeneous and unevenly distributed across modalities. Objective: To map empirical studies integrating two or more -omic modalities, summarize integration and validation approaches, and identify gaps informing future directions toward surgomics. Methods: We conducted a scoping review in accordance with PRISMA-ScR, searching PubMed, Ovid, Wiley Online Library, and Google Scholar for English-language studies published from January 2020 to 5 March 2025. We charted study characteristics, modalities combined, fusion strategies, AI model categories, validation approaches, and reported performance metrics as presented by the original studies. Results: From 184 records, 11 studies met inclusion criteria (n = 1078 total participants across reported studies), most focusing on radiomics–pathomics integration; fewer incorporated genomics, and tri-modal fusion was uncommon. Studies varied widely in clinical tasks, endpoints, preprocessing, and validation, limiting direct comparability. Conclusions: The mapped evidence indicates growing methodological activity in radiopathomics and cross-scale association modeling, while tri-modal pipelines and clinically deployable multimodal workflows remain underdeveloped. Surgomics is presented as a conceptual, staged roadmap informed by these gaps rather than a current clinical capability.

23 March 2026 in Cancers
Verified
Journal Article
Open access
PDF file
Andrew A. GumbsAndrew A. Gumbs
Andrew A. Gumbs
Roland S. CronerRoland S. Croner
Roland S. Croner
DFDavid Fuks
David Fuks
HTHadrien Tranchart
Hadrien Tranchart
ZHZacharias Heger
Zacharias Heger
IDIbrahim Dagher
Ibrahim Dagher
Background: The role of minimally invasive surgery (MIS) for hepatocellular carcinoma (HCC) remains controversial because of concerns regarding oncologic adequacy, particularly margin status. While robotic-assisted hepatectomy has gained adoption, its true perioperative advantages over conventional laparoscopy and open surgery remain unclear. SIMMILR-5 was designed to evaluate the short-term outcomes of open, laparoscopic, and tele-robotic laparoscopic hepatectomy for HCC using rigorous adjustment for confounding. Methods: A retrospective international multicenter study was conducted including patients undergoing liver resection for HCC between June 2004 and November 2024 at five high-volume hepatobiliary centers. Surgical approaches included open (O), conventional laparoscopy (L), and tele-robotic laparoscopy (TRL). Propensity score matching was performed using demographic, clinical, and tumor-related variables. The primary endpoint was short-term mortality (30 and 90 days). Secondary outcomes included estimated blood loss (EBL), operative time, length of stay (LOS), R0 resection status, and major complications. Results: A total of 904 patients were identified (302 O, 568 L, 34 TRL). After matching, conventional laparoscopy was associated with significantly lower EBL, shorter operative time, and shorter LOS compared with open surgery (all p < 0.00001). Compared with open surgery, TRL was associated with lower EBL but no improvement in operative time or LOS. Compared with laparoscopy, TRL was associated with longer operative time and longer LOS. Short-term oncologic surrogates were comparable across approaches. Conclusions: Minimally invasive hepatectomy offers perioperative advantages over open surgery for selected patients with HCC, driven primarily by conventional laparoscopy. Tele-robotic hepatectomy is feasible and safe in experienced centers but does not demonstrate superiority over advanced laparoscopic techniques.

4 September 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Andrew A. GumbsAndrew A. Gumbs
Andrew A. Gumbs
Roland S. CronerRoland S. Croner
Roland S. Croner
DFDavid Fuks
David Fuks
IDIbrahim Dagher
Ibrahim Dagher
HTHadrien Tranchart
Hadrien Tranchart
Mohammed Abu HilalMohammed Abu Hilal
Mohammed Abu Hilal
Introduction: This international multicenter study compared five surgical approaches for liver resection in colorectal metastases: open (O), standard laparoscopy (L), laparoscopy with 3D imaging (3D), laparoscopy with single robotic-arm assistance (1RA), and with complete robotic systems utilizing 4 robotic arms(4RA). A subcohort analysis was done for enhanced L, this cohort was termed collaborative assisted robotics (cobotic surgery) and consisted of L with the addition of 3D imaging or a single robotic arm to hold the laparoscope. This study aimed to evaluate whether 4RA offers any significant advantages over laparoscopy with and without cobotic enhancements. Methods: We analyzed 1,257 patients across five centers using propensity score matching. Surgical approaches were compared for blood loss, operative time, hospital stay, resection margins (R0 status), and major complications (Clavien-Dindo grade ≥3). Statistical analysis used Student's t-test and Mann-Whitney U-test for continuous variables, with p<0.05 considered significant. Results: Minimally invasive techniques without 3-D imaging, a solitary robotic arm to hold the laparoscope or utilization of handheld robotic GIA staplers showed superior outcomes to open surgery. Laparoscopic approaches demonstrated significantly reduced blood loss (L: 553 mL vs O: 695 mL, p<0.001) and shorter hospital stays when compared to open surgery (L: 8 days vs O: 14 days, p<0.001). The 4RA cohort had similar benefits when compared to O resection (blood loss: 382 mL vs 542 mL, p<0.001; LOS: 8 vs 24 days, p<0.001), but longer operative times (280 vs 305 minutes (min), p<0.001). The 1RA and 3D approaches showed comparable outcomes to 4RA in most measures. Conclusions: While robotic assistance offers technical advantages, complete robotic systems (4RA) did not demonstrate clear superiority over laparoscopy with or without cobotics. Cost-effective modular enhancements to standard laparoscopy may provide future benefits while allowing resource allocation toward AI-driven surgical innovations. Future studies should employ prospective designs with standardized protocols to validate these findings and assess long-term oncologic outcomes.