Purpose: Foot strike patterns (FSP) influence landing mechanics, with rearfoot strike (RFS) runners exhibiting higher impact loading than forefoot strike (FFS) runners. The few studies that included midfoot strike (MFS) runners have typically grouped them together with FFS. In addition, most running studies have been conducted in laboratories. Advances in wearable technology now allow the measurement of runners’ mechanics in their natural environment. The purpose of this study was to examine the relationship between FSP and impacts across a marathon race. Methods: A total of 222 healthy runners (119 males, 103 females; age, 44.1 ± 10.8 yr) running a marathon race were included. A treadmill assessment was undertaken to determine FSP. An ankle-mounted accelerometer recorded tibial shock (TS) over the course of the marathon. TS was compared between RFS, MFS, and FFS. Correlations between speed and impacts were examined between FSP. TS was also compared at the 10- and 40-km race points. Results: RFS and MFS runners exhibited similar TS (12.24g ± 3.59g vs 11.82g ± 2.68g, P = 0.46) that was significantly higher (P < 0.001 and P < 0.01, respectively) than FFS runners (9.88g ± 2.51g). In addition, TS increased with speed for both RFS (r = 0.54, P = 0.01) and MFS (r = 0.42, P = 0.02) runners, but not FFS (r = 0.05, P = 0.83). Finally, both speed (P < 0.001) and TS (P < 0.001) were reduced between the 10- and the 40-km race points. However, when normalized for speed, TS was not different (P = 0.84). Conclusions: RFS and MFS exhibit higher TS than FFS. In addition, RFS and MFS increase TS with speed, whereas FFS do not. These results suggest that the impact loading of MFS is more like RFS than FFS. Finally, TS, when normalized for speed, is similar between the beginning and the end of the race.
Background. The growth in participation in collegiate athletics has been accompanied by increased sport-related injuries. The complex and multifactorial nature of sports injuries highlights the importance of monitoring athletes prospectively using a novel and integrated biopsychosocial approach, as opposed to contemporary practices that silo these facets of health. Methods. Data collected over two competitive basketball seasons were used in a principal component analysis (PCA) model with the following objectives: (i) investigate whether biomechanical PCs (i.e., on-court and countermovement jump (CMJ) metrics) were correlated with psychological state across a season and (ii) explore whether subject-specific significant fluctuations could be detected using minimum detectable change statistics. Weekly CMJ (force plates) and on-court data (inertial measurement units), as well as psychological state (questionnaire) data, were collected on the female collegiate basketball team for two seasons. Results. While some relationships (n = 2) were identified between biomechanical PCs and psychological state metrics, the magnitude of these associations was weak (r = |0.18-0.19|, ), and no other overarching associations were identified at the group level. However, post-hoc case study analysis showed subject-specific relationships that highlight the potential utility of red-flagging meaningful fluctuations from normative biomechanical and psychological patterns. Conclusion. Overall, this work demonstrates the potential of advanced analytical modeling to characterize components of and detect statistically and clinically relevant fluctuations in student-athlete performance, health, and well-being and the need for more tailored and athlete-centered monitoring practices.
Rotator cuff repair provides pain relief for many patients; however, retears are relatively common and affect approximately 20%-70% of patients after repair. Although magnetic resonance imaging (MRI) offers the ability to assess tissue characteristics such as tear size, retraction, and fatty infiltration, it provides little insight into the quality of the musculotendinous tissues the surgeon will encounter during surgery. However, shear wave elastography (SWE) could provide an indirect assessment of quality (ie, stiffness) by measuring the speed of shear waves propagating through tissue. The objective of this study was to determine the extent to which estimated shear modulus predicts repair integrity and functional outcomes 1 year after rotator cuff repair. Thirty-three individuals scheduled to undergo arthroscopic rotator cuff repair were enrolled in this study. Before surgery, shear modulus of the supraspinatus tendon and muscle was estimated using ultrasound SWE. MRIs were obtained before and 1 year after surgery to assess tear characteristics and repair integrity, respectively. Shoulder strength, range of motion, and patient-reported pain and function were assessed before and after surgery. Functional outcomes were compared between groups and across time using a two-factor mixed model analysis of variance. Stepwise regression with model comparison was used to investigate the extent to which MRI and shear modulus predicted repair integrity and function at 1 year after surgery. At 1 year after surgery, 56.5% of patients had an intact repair. No significant differences were found in any demographic variable, presurgical tear characteristic, or shear modulus between patients with an intact repair and those with a recurrent tear. Compared with presurgical measures, patients in both groups demonstrated significant improvements at 1 year after surgery in pain (P < .01), self-reported function (P < .01), range of motion (P < .01), and shoulder strength (P < .01). In addition, neither presurgical MRI variables (P > .16) nor shear modulus (P > .52) was significantly different between groups at 1 year after surgery. Finally, presurgical shear modulus generally did not improve the prediction of functional outcomes above and beyond that provided by MRI variables alone (P > .22). Although SWE remains a promising modality for many clinical applications, this study found that SWE-estimated shear modulus did not predict repair integrity or functional outcomes at 1 year after surgery, nor did it add to the prediction of outcomes above and beyond that provided by traditional presurgical MRI measures of tear characteristics. Therefore, it appears that further research is needed to fully understand the clinical utility of SWE for musculoskeletal tissue and its potential use for predicting outcomes after surgical rotator cuff repair.
1 March 2022 in Orthopaedic Journal of Sports Medicine
Background: Rotator cuff repair is a common orthopaedic procedure that provides pain relief for many patients, but unfortunately, an estimated 20% to 70% of repair procedures will fail. Previous research has shown that elongation (ie, retraction) of a repaired tendon is common even in patients with a repair construct that appears intact on magnetic resonance imaging. However, it is unknown how this repair tissue functions under dynamic conditions. Purpose: To quantify static retraction and maximum dynamic elongation of repair tissue after rotator cuff repair. Study Design: Case series; Level of evidence, 4. Methods: Data from 9 patients were analyzed for this study. During surgery, a 3.1-mm tantalum bead was sutured to the supraspinatus tendon, medial to the repair site. Glenohumeral kinematics were assessed at 1 week (static) and 3 months (static and during scapular-plane abduction) after surgery using a biplanar videoradiographic system. The 3-dimensional position of the bead was calculated relative to the tendon’s insertion on the humerus (ie, bead-to-insertion distance). Static retraction was calculated as the change in the bead-to-insertion distance under static conditions between 1 week and 3 months after surgery, and maximum dynamic elongation was calculated as the maximal positive change in the bead-to-insertion distance during dynamic motion relative to the start of motion. The magnitudes of static retraction and maximum dynamic elongation were assessed with 1-sample t tests. Results: At 3 months after surgery, static retraction occurred in all patients by a mean of 10.0 ± 9.1 mm ( P = .01 compared with no elongation). During scapular-plane abduction, maximum dynamic elongation averaged 1.4 ± 1.0 mm ( P < .01 compared with no elongation). Descriptively, dynamic elongation consistently took 1 of 2 forms: an initial increase in the bead-to-insertion distance (mean, 2.0 ± 0.6 mm) before decreasing until the end of motion or an immediate and substantial decrease in the bead-to-insertion distance at the onset of motion. Conclusion: Repair tissue elongation (static retraction and maximum dynamic elongation) appeared to be a common and significant finding at 3 months after arthroscopic rotator cuff repair. Dynamic elongation of repair tissue during scapular-plane abduction exhibited 1 of 2 distinct patterns, which may suggest different patterns of supraspinatus mechanical and neuromuscular function.