Xiaorong Zhu

Prof. Xiaorong Zhu


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2018 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
XZXiaorong Zhu
Xiaorong Zhu
ZXZhiyun Xie
Zhiyun Xie
SJShuzhi Jing
Shuzhi Jing
HRHui Ren
Hui Ren
A dc microgrid is a low inertia system dominated by power converters. As a result, the change rate of the dc voltage is very fast under power variation. In this study, a distributed virtual inertia control is proposed to enhance the inertia of the dc microgrid and decrease the change rate of the dc voltage. The inertia of the dc microgrid can be enhanced by the kinetic energy in the rotor of the permanent magnet synchronous generators (PMSG)‐based wind turbine, the energy stored in batteries and the energy from the utility grid. By introducing a virtual inertia control coefficient, a general expression of the inertial power provided by each controllable power sources is defined. The proposed inertia control is simply a first‐order inertia loop and is implemented in the grid‐connected converter, the battery interfaced converter and the PMSG interfaced converter, respectively. The small‐signal model of the dc microgrid with the proposed inertia control is established. The range of virtual inertia control coefficient is determined through stability analysis. Finally, a typical dc microgrid is built and simulated in Matlab/Simulink, and the effectiveness of the proposed control strategy and correctness of the stability analysis are verified.

19 September 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
XZXiaorong Zhu
Xiaorong Zhu
YSYu Si
Yu Si
The cyber-physical deep coupling exacerbates the challenge of restoring the load power supply of the distribution network (DN) after a power outage. Serving as interface devices between the DN and the traffic network (TN), mobile energy storage systems (MESSs) play a crucial role in load recovery. To enhance the emergency response, a multi-period dynamic power supply restoration strategy for DN is proposed in this article, which considers the coupling of physical, cyber and traffic networks. Firstly, a power supply restoration model of the DN is established. This model includes an objective function, load of DN, wind-photovoltaic-energy storage system (WPESS) and its topology constraints, operation constraints of MESSs, and information network (IN) constraints. The virtual power flow theory is employed to ensure the radial topology of the DN, while the second-order cone relaxation method is utilized for branch power flow convexification. The operation status is studied, and the traffic model of the IN is established using the network flow theory. Secondly, a dynamic transmission model of MESSs is created. The Floyd algorithm is chosen to determine the shortest path. Finally, case studies are conducted to demonstrate the efficacy and superiority of the proposed strategy.

9 October 2025 in Electronics
Verified
Journal Article
Open access
PDF file
GJGeling Jiang
Geling Jiang
SKSiyu Kan
Siyu Kan
LYLi Yuhang
Li Yuhang
XZXiaorong Zhu
Xiaorong Zhu
To address the problem of transient disturbance arising during the grid-following (GFL) and grid-forming (GFM) mode switching of energy storage converters, this paper proposes a dual-mode seamless switching control strategy. First, we conduct an in-depth analysis of the mechanism behind switching transients, identifying that sudden changes in current commands and angle-control misalignment are the key factors triggering oscillations in system power and voltage frequency. To overcome this, we design a virtual synchronous generator (VSG) control angle-tracking technique based on the construction of triangular functions, which effectively eliminates the influence of periodic phase-angle jumps on tracking accuracy and achieves precise pre-synchronization of the microgrid phase in GFM mode. Additionally, we employ a current-command seamless switching technique involving real-time latching and synchronization of the inner-loop current references between the two modes, ensuring continuity of control commands at the switching instant. The simulation and hardware-in-the-loop (HIL) experimental results show that the proposed strategy does not require retuning of the parameters after switching, greatly suppresses voltage and frequency fluctuations during mode transition, and achieves smooth, rapid, seamless switching between the GFL and GFM modes of the energy storage converter, thereby improving the stability of microgrid operation.

18 June 2025 in Electronics
Verified
Journal Article
Open access
PDF file
KWKeming Wu
Keming Wu
JHJiajing Hao
Jiajing Hao
ZCZelong Chen
Zelong Chen
JYJinshi You
Jinshi You
SCShuai Cao
Shuai Cao
XZXiaorong Zhu
Xiaorong Zhu
With the rapid development of renewable energy in China, thermal power units are facing decommissioning issues, while the power system is confronted with severe challenges such as reduced grid strength and insufficient voltage support. For power systems with multiple renewable energy stations, the short-circuit ratio at the connection points of renewable energy stations is an important indicator for measuring grid strength. Engineering requirements specify that the short-circuit ratio at these connection points should not be lower than 2.0. This study focuses on transforming retired thermal power units into synchronous condensers to improve the short-circuit ratio at renewable energy station connection points. This paper first studies the impact of thermal power unit operation, shutdown, and synchronous phasor operation on the short-circuit ratio, deriving the short-circuit ratio expressions for renewable energy stations under different states of thermal power units. It further analyzes the impact of different main transformer capacities and unit transformation capacities on the short-circuit ratio. Next, a multi-dimensional evaluation system is constructed, incorporating the change in short-circuit ratio at grid-connection points of multiple renewable energy stations (ΔMRSCRS), the main transformer capacity within short-circuit ratio enhancement range (ST), the pre-retrofit short-circuit ratio level at grid-connection points of multiple renewable energy stations (SG), and the retrofitted unit capacity (MRSCRS) to comprehensively assess the transformed thermal power units. Finally, a case analysis conducted on the modified IEEE-39 bus system using the PSASP platform verifies that operating thermal power units as synchronous condensers can significantly enhance the short-circuit ratios of multiple renewable energy sites. Given that small-capacity thermal units are approaching retirement, there is a stronger preference for retrofitting these smaller units as synchronous condensers. The multi-dimensional evaluation method proposed in this study specifically identifies small-capacity thermal units as the most suitable candidates for such retrofitting. This approach provides theoretical support for implementing synchronous condenser operation in retired thermal power units and promotes the coordinated optimization of grid security and renewable energy integration.