This paper develops a fully automatic tool for the denoising of partial discharge (PD) signals occurring in electrical power networks and recorded in on-site measurements. The proposed method is based on the spectral decomposition of the PD measured signal via the joint application of the short-time Fourier transform and the singular value decomposition. The estimated noiseless signal is reconstructed via a clever selection of the dominant contributions, which allows us to filter out the different spurious components, including the white noise and the discrete spectrum noise. The method offers a viable solution which can be easily integrated within the measurement apparatus, with unavoidable beneficial effects in the detection of important parameters of the signal for PD localization. The performance of the proposed tool is first demonstrated on a synthetic test signal and then it is applied to real measured data. A cross comparison of the proposed method and other state-of-the-art alternatives is included in the study.
The burgeoning demand for enhanced power-system safety means that there is increased attention on technologies for the detection and location of cable faults. The double-terminal fault location method, which senses a fault current using a current transformer (CT), is the most effective and widely applied method in industrial practice. However, CT sensors may suffer from magnetic saturation when exposed to a high fault current, resulting in significant location errors, and their sensitivity cannot be adjusted. To address this problem, this paper describes an improved method for the acquisition of fault signal and the identification of fault-wave arrival time in power cables. First, a novel noncontact sensor (NCS) is developed for the detection of electric fields, and its sensitivity-adjustment curves are obtained by theoretical calculation and simulation. Then, based on feedback variational mode decomposition (FVMD) and the Wigner-Ville distribution (WVD), an improved method (the FVMD + WVD method) for the identification of fault-wave arrival time is devised, and its efficacy and accuracy are verified by simulations in Power Systems Computer-Aided Design/Electromagnetic Transients including DC (PSCAD/EMTDC) software. Finally, the fault-wave arrival-time detection performance of the NCS is examined in a series of on-site DC and AC experiments based on damped AC technology. The results show that the NCS exhibits feasible and effective performance, and that its response can be appropriately tuned based on its sensitivity-adjustment curves. The FVMD + WVD method is more accurate than several other current methods, as its error is only 0.48%, and thus this method enables the practical location of cable faults. In sum, these findings demonstrate that the NCS and the FVMD + WVD method comprise an improved system for the detection and location of cable faults, which will enhance cable safety in power systems.
14 June 2021 in IEEE Transactions on Power Delivery
Identifying the location of partial discharges (PDs) and providing clear information on insulation vulnerabilities in power systems can help utility companies to improve their maintenance efficiency. This paper presents a PD monitoring and locating system for medium-voltage switchgears using a set of transient earth voltage (TEV) detectors. A time-of-flight methodology was used to identify the switchgear affected by PD among a row of switchgears. A time sharing access mechanism, which was implemented by multiple high-frequency surface mounting relays integrated into each TEV detector, was applied to automatically identify the site of PD and minimize the number of expensive high-speed acquisition cards. The operation principle and implementation of the modular system were formulated, and the efficiency of the proposed system in identifying the switchgear with PD among three 10 kV metal-clad switchgears was confirmed experimentally.
10 November 2022 in IEEE Transactions on Power Delivery
This paper proposes an innovative partial discharge (PD) location technique for overhead electrical power distribution networks. It is aimed at improving the condition-based maintenance of the network. PD localization is carried out via an improved double-sided traveling-wave method. The method is driven by a hybrid detection technique, which integrates a pulse-based synchronization mechanism and a global positioning system (GPS). The proposed solution offers a number of benefits. It has the nice inherent feature of being immune to varying physical parameters of the transmission line, and it has been proven be offer improved accuracy with respect of the conventional GPS-based location methods. Also, an in-house designed portable and non-invasive test setup is presented and thoroughly discussed, thus demonstrating the feasibility of the proposed method. Moreover, an enhanced algorithm is embedded into the PD location system to improve robustness to high-level noise. Finally, the proposed tool relies on a well-established automatic procedure which requires neither parameter tuning nor any expert intervention. The features and strengths of the method are validated on a real case consisting of a 2125-m long 10-kV overhead covered conductor line.
10 January 2020 in IEEE Transactions on Power Delivery
Damped AC (DAC) technique has proven to be one of the most acceptable techniques for on-site partial discharge (PD) detection. However, the expensive high-voltage switches, used in the DAC system, impede the further spread of the technique. This letter presents a low-cost DAC system for PD test of high-voltage cables. The DAC voltage is generated by the frequency-tuned series resonant technique and two cost-effective switches which have relatively low rated voltage. Since the system uses a capacitor bank, high input power is not necessary. This letter describes the design and implementation of the system. An experimental study and an on-site test validate the effectiveness of the proposed system.
26 December 2024 in IEEE Transactions on Instrumentation and Measurement
Partial discharge (PD) diagnosis is a crucial technique for assessing the insulation condition of high-voltage (HV) cables. The double-sided travelling wave method is effective for online PD localization on HV cables. However, the PD localization accuracy is limited by three main factors: inaccurate time synchronization among sensors, imprecise pulse propagation velocity, and noise interference. To address these issues, a bidirectional pulse-injected time synchronization method is proposed to correct the timing bases of detectors and assess the pulse propagation velocity along cables independently of cable parameters. Furthermore, a denoising method combining the short-time Fourier transform (STFT) and variational mode decomposition (VMD) is designed to enhance the robustness of the system to high-intensity noise. Finally, an integrated PD detector with pulse injection and signal detection functions and switchable measurement ranges is designed to improve detection sensitivity. To validate the effectiveness of the proposed method, a portable system is developed, and experiments are conducted on both a 10 kV cable in the laboratory and a 110 kV cable in the field. The experimental results confirm that the proposed method enhances the accuracy of PD localization.