Ricardo A. Spampinato

Dr. Ricardo A. Spampinato


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in Heart Rhythm
Verified
Journal Article
Closed access
TSTimm Seewöster
Timm Seewöster
RSRicardo A. Spampinato
Ricardo A. Spampinato
PSPhilipp Sommer
Philipp Sommer
FLFrank Lindemann
Frank Lindemann
CJCosima Jahnke
Cosima Jahnke
JKJelena Kornej
Jelena Kornej

1 March 2021 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
RSRicardo A. Spampinato
Ricardo A. Spampinato
CJCosima Jahnke
Cosima Jahnke
GCGerard Crelier
Gerard Crelier
FLFrank Lindemann
Frank Lindemann
FFFlorian Fahr
Florian Fahr
IPIngo Paetsch
Ingo Paetsch
Four-dimensional cardiovascular magnetic resonance (CMR) flow assessment (4D flow) allows to derive volumetric quantitative parameters in mitral regurgitation (MR) using retrospective valve tracking. However, prior studies have been conducted in functional MR or in patients with congenital heart disease, thus, data regarding the usefulness of 4D flow CMR in case of a valve pathology like mitral valve prolapse (MVP) are scarce. This study aimed to evaluate the clinical utility of cine-guided valve segmentation of 4D flow CMR in assessment of MR in MVP when compared to standardized routine CMR and transthoracic echocardiography (TTE). Six healthy subjects and 54 patients (55 ± 16 years; 47 men) with MVP were studied. TTE severity grading used a multiparametric approach resulting in mild/mild-moderate (n = 12), moderate-severe (n = 12), and severe MR (n = 30). Regurgitant volume (RVol) and regurgitant fraction (RF) were also derived using standard volumetric CMR and 4D flow CMR datasets with direct measurement of regurgitant flow (4DFdirect) and indirect calculation using the formula: mitral valve forward flow - left ventricular outflow tract stroke volume (4DFindirect). There was moderate to strong correlation between methods (r = 0.59–0.84, p < 0.001), but TTE proximal isovelocity surface area (PISA) method showed higher RVol as compared with CMR techniques (PISA vs. CMR, mean difference of 15.8 ml [95% CI 9.9–21.6]; PISA vs. 4DFindirect, 17.2 ml [8.4–25.9]; PISA vs. 4DFdirect, 27.9 ml [19.1–36.8]; p < 0.001). Only indirect CMR methods (CMR vs. 4DFindirect) showed moderate to substantial agreement (Lin’s coefficient 0.92–0.97) without significant bias (mean bias 1.05 ± 26 ml [− 50 to 52], p = 0.757). Intra- and inter-observer reliability were good to excellent for all methods (ICC 0.87–0.99), but with numerically lower coefficient of variation for indirect CMR methods (2.5 to 12%). In the assessment of patients with MR and MVP, cine-guided valve segmentation 4D flow CMR is feasible and comparable to standard CMR, but with lower RVol when TTE is used as reference. 4DFindirect quantification has higher intra- and inter-technique agreement than 4DFdirect quantification and might be used as an adjunctive technique for cross-checking MR quantification in MVP.

1 August 2020 in Journal of Cardiology
Verified
Journal Article
Closed access
RSRicardo A. Spampinato
Ricardo A. Spampinato
RBRafal Bochen
Rafal Bochen
FSFranz Sieg
Franz Sieg
SWStefan Weiss
Stefan Weiss
JKJelena Kornej
Jelena Kornej
MBMichael A. Borger
Michael A. Borger

18 April 2020 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
RSRicardo A. Spampinato
Ricardo A. Spampinato
CJCosima Jahnke
Cosima Jahnke
IPIngo Paetsch
Ingo Paetsch
SHSebastian Hilbert
Sebastian Hilbert
SLSusanne Löbe
Susanne Löbe
MBMichael A. Borger
Michael A. Borger
Transthoracic echocardiography (TTE) and cardiac magnetic resonance (CMR) are current standard for assessing aortic regurgitation (AR). Regurgitant fraction (RF) can also be estimated by Doppler examination of the left subclavian artery (LSA-Doppler). However, a comparison of AR grading scales using these methods and a TTE multiparametric approach as reference is lacking. We evaluated the severity of AR in 73 patients (58 ± 15 years; 57 men), with a wide spectrum of AR of the native valve. Using a recommended TTE multiparametric approach the AR was divided in none/trace (n = 12), mild (n = 23), moderate (n = 12), and severe (n = 26). RF was evaluated by LSA-Doppler (ratio between diastolic and systolic velocity–time integrals) and by CMR phase-contrast imaging (performed in the aorta 1 cm above the aortic valve); the grading scales were then calculated. There were a good correlation between all methods, but mean RF values were greater with TTE compared with LSA-Doppler and CMR (39 ± 16% vs. 35 ± 18% vs. 32 ± 20%, respectively; p < 0.037). Mean differences in RF values between methods were significant in the groups with mild and moderate AR. Grading scales that best defined the TTE derived AR severity using CMR were: mild, < 21%; moderate, 22 to 41%; and severe, > 42%; and using LSA-Doppler: mild, < 29%; moderate, 30 to 44%; and severe, > 45%. RF values for AR grading using TTE, LSA-Doppler and CMR correlate well but differ in groups with mild and moderate AR when using a recognized multiparametric echocardiographic approach. Clinical prospective studies should validate these proposed modality adjusted grading scales.

22 February 2021 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
RSRicardo A. Spampinato
Ricardo A. Spampinato
FLFrank Lindemann
Frank Lindemann
CJCosima Jahnke
Cosima Jahnke
IPIngo Paetsch
Ingo Paetsch
FFFlorian Fahr
Florian Fahr
MBMichael A. Borger
Michael A. Borger
Three-dimensional transthoracic echocardiography (3D-TTE) provides a semi-automated proximal isovelocity surface area method (3D-PISA) to obtain quantitative parameters. Data assessing regurgitation severity in mitral valve prolapse (MVP) are scarce, so we assessed the 3D-PISA method compared with 2D-PISA and cardiovascular magnetic resonance (CMR) and the role of an eccentricity index. We evaluated the 3D-PISA method for assessing MR in 54 patients with MVP (57 ± 14 years; 42 men; 12 mild/mild-moderate; 12 moderate-severe; and 30 severe MR). Role of an asymmetric (i.e. eccentricity index ≥ 1.25) flow convergence region (FCR) and inter-modality consistency were then assessed. 3D-PISA derived regurgitant volume (RVol) showed a good correlation with 2D-PISA and CMR derived parameters (r = 0.86 and r = 0.81, respectively). The small mean differences with 2D-PISA derived RVol did not reach statistical significance in overall population (5.7 ± 23 ml, 95% CI − 0.6 to 12; p = 0.08) but differed in those with asymmetric 3D-FCR (n = 21; 2D-PISA: 72 ± 36 ml vs. 3D-PISA: 93 ± 47 ml; p = 0.001). RVol mean values were higher using PISA methods (CMR 57 ± 33 ml; 2D-PISA 73 ± 39 ml; and 3D-PISA 79 ± 45 ml) and an overestimation was observed when CMR was used as reference (2D-PISA vs. CMR: mean difference: 15.8 ml [95% CI 10–22, p < 0.001]; and 3D-PISA vs. CMR: 21.5 ml [95% CI 14–29, p < 0.001]). Intra- and inter-observer reliability was excellent (ICC 0.91–0.99), but with numerically lower coefficient of variation for 3D-PISA (8%–10% vs. 2D-PISA: 12%–16%). 3D-PISA method for assessing regurgitation in MVP may enable analogous evaluation compared to standard 2D-PISA, but with overestimation in case of asymmetric FCR or when CMR is used as reference method.

28 October 2023 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
RSRicardo A. Spampinato
Ricardo A. Spampinato
MMMateo Marin-Cuartas
Mateo Marin-Cuartas
AKAntonia van Kampen
Antonia van Kampen
FFFlorian Fahr
Florian Fahr
FSFranz Sieg
Franz Sieg
MBMichael A. Borger
Michael A. Borger