Effective environmental monitoring is critical for preventing microbial and allergenic cross-contamination. However, manual swabbing methods, commonly used to verify hygienic conditions, are prone to inconsistent results because of variability in pressure, coverage, and techniques. Two novel solutions will be explored to address these challenges: a robotic swabbing system with tactile sensing control, and a fluorescence/absorbance spectrometer for non-contact, protein-based residue detection. The robotic system was evaluated against trained and untrained humans, measuring water pickup, surface coverage, and pressure consistency. Concurrently, the fluorescence system analyzed model poultry protein soil to correlate spectral patterns with contamination levels. The robotic system demonstrated statistically superior performance, achieving consistent force application and near-complete surface coverage, overcoming key limitations of manual sampling. The fluorescence system distinguished contamination with high sensitivity, validating its use as a rapid, non-contact assessment tool. Together, the robotic sample acquisition and the spectrometer’s sensitive analysis provide a dual-modality framework for enhancing hygiene monitoring in manufacturing facilities.
Color and fluorescence spectrometry were evaluated as rapid, objective tools for verifying the cleanliness of poultry-processing food-contacting surfaces contaminated with a model chicken solution across six common materials. Both techniques detected chicken residues at dilutions several orders of magnitude below human visual and olfactory thresholds, with stainless steel and blue plastic yielding the largest color differences between clean and contaminated states and fluorescence measurements remaining highly sensitive on all tested surfaces. Representative limits of detection were on the order of 1:50–1:100 dilution of chicken residue for color measurements on most surfaces and approximately 1:50 for fluorescence measurements, compared with human detection thresholds of approximately 1:50. Cleaning chemicals routinely used in poultry plants did not measurably reduce detection performance, and a simple machine learning classifier further improved separation of clean versus contaminated readings. These findings indicate that compact color and fluorescence instruments can provide fast, quantitative pre-sanitation checks that strengthen SSOP verification and reduce reliance on subjective human inspection in poultry processing facilities.