Panagiotis Megas

Dr. Panagiotis Megas


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2018 in Journal of Medical Case Reports
Verified
Journal Article
Open access
PDF file
APAndreas Panagopoulos
Andreas Panagopoulos
ITIrini TATANI
Irini TATANI
HKHelen (Eleni) Kourea
Helen (Eleni) Kourea
ZKZ. T. Kokkalis
Z. T. Kokkalis
KPK. Panagopoulos
K. Panagopoulos
PMPanagiotis Megas
Panagiotis Megas
Brown tumors represent a rare clinical manifestation reported in approximately 3% of patients with primary hyperparathyroidism and correspond to radiologically osteolytic lesions with well-defined borders in different parts of the skeleton. We report the case of a 53-year-old white man who presented to our hospital with osteolytic lesions of his distal ulna and radius, causing pain and swelling of 2-month duration. A subsequent biopsy revealed histological features consistent with giant cell tumor and a complete resection of his distal ulna was followed, along with curettage and cementoplasty of the distal radial metaphysis. Two weeks later, he was re-admitted with diffuse musculoskeletal soreness, anorexia, constipation, nausea, and localized abdominal pain and multiple osteolytic lesions on plain radiographs. A histopathological examination of the ulna and radius specimens showed similar findings and, given the multifocality, brown tumors related to primary or secondary hyperparathyroidism was included in the differential diagnosis. A laboratory examination showed high total serum calcium (14.5 mg/dl) and low serum phosphorus and 25-hydroxyvitamin D levels. Primary hyperparathyroidism was suspected and confirmed by the elevated parathyroid hormone levels of 1453 pg/mL. At radiological work-up, using computed tomography, ultrasonography, and parathyroid subtraction technetium-99m sestamibi scintigraphy, a 4.5 × 2.5 × 3.2 cm mass emanating from the right lobe of his thyroid gland was detected, displaying extensive uptake in the right lower parathyroid gland. After appropriate medical support including hyperhydration and high doses of diuretics and diphosphonates, his laboratory profile normalized and he underwent total thyroidectomy with removal of the parathyroid glands. Our patient is now recovering 12 months after surgery, with normal values of serum parathyroid hormone and calcium levels. The lytic bone lesions have almost disappeared and no other additional orthopedic intervention was necessary. The present case report emphasizes the need of inclusion of brown tumors in the differential diagnosis of multifocal osteolytic bone lesions, in order to avoid harmful surgical interventions. Laboratory testing of serum phosphate, calcium levels, and parathyroid hormone levels should always be included in the routine survey of patients with multifocal osteolytic lesions.

17 June 2019 in Trials
Verified
Journal Article
Open access
PDF file
ITIrini TATANI
Irini TATANI
APAndreas Panagopoulos
Andreas Panagopoulos
IDI. Diamantakos
I. Diamantakos
GSG. Sakellaropoulos
G. Sakellaropoulos
Spiros PantelakisSpiros Pantelakis
Spiros Pantelakis
PMPanagiotis Megas
Panagiotis Megas
Total hip replacement has recently followed a progressive evolution towards principles of bone- and soft-tissue-sparing surgery. Regarding femoral implants, different stem designs have been developed as an alternative to conventional stems, and there is a renewed interest towards short versions of uncemented femoral implants. Based on both experimental testing and finite element modeling, the proposed study has been designed to compare the biomechanical properties and clinical performance of the newly introduced short-stem Minima S, for which clinical data are lacking with an older generation stem, the Trilock Bone Preservation Stem with an established performance record in short to midterm follow-up. In the experimental study, the transmission of forces as measured by cortical surface-strain distribution in the proximal femur will be evaluated using digital image correlation (DIC), first on the non-implanted femur and then on the implanted stems. Finite element parametric models of the bone, the stem and their interface will be also developed. Finite element predictions of surface strains in implanted composite femurs, after being validated against biomechanical testing measurements, will be used to assist the comparison of the stems by deriving important data on the developed stress and strain fields, which cannot be measured through biomechanical testing. Finally, a prospective randomized comparative clinical study between these two stems will be also conducted to determine (1) their clinical performance up to 2 years’ follow-up using clinical scores and gait analysis (2) stem fixation and remodeling using a detailed radiographic analysis and (3) incidence and types of complications. Our study would be the first that compares not only the clinical and radiological outcome but also the biomechanical properties of two differently designed femoral implants that are theoretically classified in the same main category of cervico-metaphyseal-diaphyseal short stems. We can hypothesize that even these subtle variations in geometric design between these two stems may create different loading characteristics and thus dissimilar biomechanical behaviors, which in turn could have an influence to their clinical performance. International Standard Randomized Controlled Trial Number, ID: ISRCTN10096716 . Retrospectively registered on May 8 2018.

19 August 2020 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
ITIrini TATANI
Irini TATANI
PMPanagiotis Megas
Panagiotis Megas
APAndreas Panagopoulos
Andreas Panagopoulos
IDI. Diamantakos
I. Diamantakos
PNPh. Nanopoulos
Ph. Nanopoulos
Spiros PantelakisSpiros Pantelakis
Spiros Pantelakis
Background: The progressive evolution in hip replacement research is directed to follow the principles of bone and soft tissue sparing surgery. Regarding hip implants, a renewed interest has been raised towards short uncemented femoral implants. A heterogeneous group of short stems have been designed with the aim to approximate initial, post-implantation bone strain to the preoperative levels in order to minimize the effects of stress shielding. This study aims to investigate the biomechanical properties of two distinctly designed femoral implants, the TRI-LOCK Bone Preservation Stem, a shortened conventional stem and the Minima S Femoral Stem, an even shorter and anatomically shaped stem, based on experiments and numerical simulations. Furthermore, finite element models of implant–bone constructs should be evaluated for their validity against mechanical tests wherever it is possible. In this work, the validation was performed via a direct comparison of the FE calculated strain fields with their experimental equivalents obtained using the digital image correlation technique.Results: Design differences between Trilock BPS and Minima S femoral stems conditioned different strain pattern distributions. A distally shifting load distribution pattern as a result of implant insertion and also an obvious decrease of strain in the medial proximal aspect of the femur was noted for both stems. Strain changes induced after the implantation of the Trilock BPS stem at the lateral surface were greater compared to the non-implanted femur response, as opposed to those exhibited by the Minima S stem. Linear correlation analyses revealed a reasonable agreement between the numerical and experimental data in the majority of cases.Conclusion: The study findings support the use of DIC technique as a preclinical evaluation tool of the biomechanical behavior induced by different implants and also identify its potential for experimental FE model validation. Furthermore, a proximal stress-shielding effect was noted after the implantation of both short-stem designs. Design-specific variations in short stems were sufficient to produce dissimilar biomechanical behaviors, although their clinical implication must be investigated through comparative clinical studies.

19 July 2011 in The Open Orthopaedics Journal
Verified
Journal Article
Open access
ETE.G Theodorou
E.G Theodorou
CPC.G Provatidis
C.G Provatidis
GBG.C Babis
G.C Babis
CGC.S Georgiou
C.S Georgiou
PMPanagiotis Megas
Panagiotis Megas
Total Hip Arthroplasty aims at fully recreating a functional hip joint. Over the past years modular implant systems have become common practice and are widely used, due to the surgical options they provide. In addition Big Femoral Heads have also been implemented in the process, providing more flexibility for the surgeon. The current study aims at investigating the effects that femoral heads of bigger diameter may impose on the mechanical behavior of the bone-implant assembly. Using data acquired by Computed Tomographies and a Coordinate Measurement Machine, a cadaveric femur and a Profemur-E modular stem were fully digitized, leading to a three dimensional finite element model in ANSYS Workbench. Strains and stresses were then calculated, focusing on areas of clinical interest, based on Gruen zones: the calcar and the corresponding below the greater trochanter area in the proximal femur, the stem tip region and a profile line along linea aspera. The performed finite elements analysis revealed that the use of large diameter heads produces significant changes in strain development within the bone volume, especially in the lateral side. The application of Frost’s law in bone remodeling, validated the hypothesis that for all diameters normal bone growth occurs. However, in the calcar area lower strain values were recorded, when comparing with the reference model featuring a 28mm femoral head. Along line aspera and for the stem tip area, higher values were recorded. Finally, stresses calculated on the modular neck revealed increased values, but without reaching the yield strength of the titanium alloy used.

31 December 2014 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
PMPanagiotis Megas
Panagiotis Megas
CGChristos S. Georgiou
Christos S. Georgiou
APAndreas Panagopoulos
Andreas Panagopoulos
AKAntonis Kouzelis
Antonis Kouzelis
The transfemoral and the extended trochanteric osteotomies are the most common osteotomies used in femoral revision, both when proximal or diaphyseal fixation of the new component has been decided. We present an alternative approach to the trochanteric osteotomies, most frequently used with distally fixated stems, to overcome their shortcomings of osteotomy migration and nonunion, but, most of all, the uncontrollable fragmentation of the femur. The procedure includes a complete circular femoral osteotomy just below the stem tip to prevent distal fracture propagation and a subsequent preplanned segmentation of the proximal femur for better exposure and fast removal of the old prosthesis. The bone fragments are reattached with cerclage wires to the revision prosthesis, which is safely anchored distally. A modified posterolateral approach is used, as the preservation of the continuity of the abductors, the greater trochanter, and the vastus lateralis is a prerequisite. Between 2006 and 2012, 47 stems (33 women, 14 men, mean age 68 years, range 39–88 years) were revised using this technique. They were 12 (26%) stable and 35 (74%) loose prostheses and were all revised to tapered, fluted, grit-blasted stems. No fracture of the trochanters or the distal femur occurred intraoperatively. Mean follow-up was 28 months (range 6–70 months). No case of trochanteric migration or nonunion of the osteotomies was recorded. Restoration of the preexisting bone defects occurred in 83% of the patients. Three patients required repeat revision due to dislocation and one due to a postoperative periprosthetic fracture. None of the failures was attributed to the procedure itself. This new osteotomy technique may seem aggressive at first, but, at least in our hands, has effectively increased the speed of the femoral revision, particularly for the most difficult well-fixed components, but not at the expense of safety.

31 October 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
KSKonstantina Solou
Konstantina Solou
ASAnna Vasiliki Solou
Anna Vasiliki Solou
ITIrini TATANI
Irini TATANI
JLJohn Lakoumentas
John Lakoumentas
Konstantinos TserpesKonstantinos Tserpes
Konstantinos Tserpes
PMPanagiotis Megas
Panagiotis Megas
Stress shielding and aseptic loosening have been identified as adverse effects of short-stem total hip arthroplasty resulting in hardware failure. However, there is a gap in research regarding the impact of stress shielding in customized porous coatings. The purpose of this study was to optimize the distribution of the coefficients of friction in the porous coating of a metaphyseal femoral stem to minimize stress shielding. Static structural analysis of an implanted short, tapered-wedge stem with a titanium porous coating was performed with the use of Analysis System Mechanical Software under axial loading. To limit computational time, we randomly sampled only 500 of the possible combinations of coefficients of friction. Results indicate that the coefficient of friction in the distal lateral porous coating significantly affected the mid-distal medial femoral surface and lateral femoral surface. The resultant increased proximal strains resulted from an increased coefficient of friction in lateral porous coating and a reduction in the coefficient of friction in medial mid-distal coating. These findings suggest that a customized porous coating distribution may produce strain patterns that are biomechanically closer to intact bone, thereby reducing stress shielding in short femoral stems.