The objective of the article is to provide an accurate model of the human cochlea with which potential distributions and thus neural excitation patterns around cochlear implant electrodes can be determined. Improvements on previous models of the implanted cochlea are that this model 1) includes the spiral nature of the cochlea as well as many other anatomical details (and it is a model of the human cochlear rather than the guinea pig cochlea), and 2) facilitates modeling of different electrode geometries, array locations and electrode separations without changing the structure of the model. A three-dimensional spiraling finite element model of the human cochlea was created. The model incorporates the effect of neighboring canals and conduction along the fluid-filled canals of the cochlea. Potential distributions are used as inputs to a nerve fiber model to investigate auditory nerve excitation patterns around intracochlear electrode arrays. Potential distributions around intracochlear electrodes generated with the finite element model are presented. The effects of electrode separation, electrode geometry and array location on excitation threshold, excitation spread and ectopic excitation (i.e., excitation of nerve fibers at an undesirable location) are demonstrated. The following conclusions should be considered preliminary, as their accuracy depends on the exactness of the underlying model. The spiraling geometry of the cochlea causes asymmetry in potential distributions. The location of electrodes along the length of the basilar membrane has a stronger influence on the site of excitation than the polarity of the leading phase of the stimulus. Array location is the primary parameter that controls excitation spread. Threshold currents and the effect of ongoing loss of peripheral dendrites on threshold currents can be limited by placing arrays close to the modiolus. Point electrode geometries are recommended above banded electrode geometries only when the array can be placed close to the modiolus. There is a tradeoff between array location and the degree of ectopic stimulation caused by a specific array location. Bimodal excitation patterns exist at comfortable stimulus intensities for longitudinal bipolar electrode configurations. It is shown that an electrode configuration with an electrode separation of approximately half that of the bipolar electrode separation of the Nucleus electrode can be used instead of radial and offset radial electrode configurations to create unimodal excitation patterns. The stimulation resolution of cochlear implant electrode arrays can potentially be improved by increasing the number of electrode contacts in an array.
2 October 2015 in International Journal for Numerical Methods in Biomedical Engineering
Increasing the selectivity of the detection system in surface electromyography (EMG) is beneficial in the collection of information of a specific portion of the investigated muscle and to reduce the contribution of undesired components, such as non-propagating components (due to generation or end-of-fibre effects) or crosstalk from nearby muscles. A comparison of the ability of different spatial filters to reduce the amount of crosstalk in surface EMG measurements was conducted in this paper using simulated signals. It focused on the influence of different properties of the muscle anatomy (changing subcutaneous layer thickness, skin conductivity, fibre length) and detection system (single, double and normal double differential, with two inter-electrode distances - IED) on the amount of crosstalk present in the measurements. A cylindrical multilayer (skin, subcutaneous tissue, muscle, bone) analytical model was used to simulate single fibre action potentials (SFAPs). Fibres were grouped together in motor units (MUs) and motor unit action potentials (MUAPs) were obtained by adding the SFAPs of the corresponding fibres. Interference surface EMG signals were obtained, modelling the recruitment of MUs and rate coding. The average rectified value (ARV) and mean frequency (MNF) content of the EMG signals were studied and used as a basis for determining the selectivity of each spatial filter. From these results it was found that the selectivity of each spatial filter varies depending on the transversal location of the measurement electrodes and on the anatomy. An increase in skin conductivity favourably affects the selectivity of normal double differential filters as does an increase in subcutaneous layer thickness. An increase in IED decreases the selectivity of all the analysed filters.
12 April 2016 in Network: Computation in Neural Systems
Three-dimensional (3D) computational modeling of the auditory periphery forms an integral part of modern-day research in cochlear implants (CIs). These models consist of a volume conduction description of implanted stimulation electrodes and the current distribution around these, coupled with auditory nerve fiber models. Cochlear neural activation patterns can then be predicted for a given input stimulus. The objective of this article is to present the context of 3D modeling within the field of CIs, the different models, and approaches to models that have been developed over the years, as well as the applications and potential applications of these models. The process of development of 3D models is discussed, and the article places specific emphasis on the complementary roles of generic models and user-specific models, as the latter is important for translation of these models into clinical application.