Om Hari Gupta

Dr. Om Hari Gupta


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2015 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
OGOm Hari Gupta
Om Hari Gupta
MTManoj Tripathy
Manoj Tripathy
This paper presents a fault detection and classification scheme for a shunt [static var compensator (SVC)] compensated line. The proposed relaying scheme is based on the concept of superimposed sequence components-based integrated impedance (SSCII). For an internal fault, the magnitude of SSCII is small and for an external fault, it is very large. In the SVC compensated line, a fault forces SVC to vary its impedance. Superimposed components are injected due to this impedance variation, along with the fault components. These SVC-injected components are treated as fault-injected components and, therefore, even the sound phases are detected as faulty phases. To avoid such failure, fault-injected superimposed components have been extracted by using the modified prefault data, which is estimated according to SVC impedance variations. The superimposed components measured using the modified prefault data consist of fault-injected superimposed components only. The proposed scheme has been tested for all types of faults, different values of fault resistances, and several fault locations and SVC locations. The results demonstrate that the proposed scheme successfully detects and classifies the faults. Also, the proposed scheme is robust against variations in fault resistance, source impedance, and SVC location.

31 October 2019 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
OGOm Hari Gupta
Om Hari Gupta
MTManoj Tripathy
Manoj Tripathy
VSVijay K. Sood
Vijay K. Sood
This study presents a new method for detecting an islanding event in a microgrid with embedded converter‐based distributed generation (DG). Unlike other schemes, the proposed scheme injects negligible perturbations into the microgrid after the generation of an alert signal. The proposed scheme then uses another index called superimposed impedance, Δ Z . The Δ Z is characterised by a low steady‐state magnitude during the grid‐connected mode and a high magnitude during the islanded mode. Furthermore, for a fault at the point of common coupling (PCC), the magnitudes of Δ Z and PCC voltage are both very low – except during the initial transient period, where |Δ Z | momentarily crosses the threshold. Therefore, an islanding event can be detected if the magnitude of Δ Z is high for some specified time. Moreover, a fault event will not be misdirected as an islanding event because the steady‐state magnitudes of both the Δ Z and PCC voltage are very low in the case of a fault. The robustness of the proposed detection scheme is evaluated against different islanding conditions and also, for a fault at the PCC, first by using MATLAB‐based simulations and later by using a laboratory‐based experimental setup. A comparison with a recently published detection scheme shows the superiority of the proposed schemes.

3 November 2022 in IETE Technical Review
Verified
Journal Article
Closed access
KKKamal Kant
Kamal Kant
OGOm Hari Gupta
Om Hari Gupta
The development of microgrids can prove to be a path-breaking concept in the realization of future smart grids. The increasing trends of automation in domestic loads and smart homes have increased the penetration of DC loads at the distribution level. Hence, the development of a low- or medium-voltage DC microgrid seems the need of the hour to match this changing scenario. Another point is that the various distributed generation (DG) sources like PV, batteries, fuel cells, etc., also provide energy in DC form. Hence, integrating these sources into the DC system also becomes convenient as the power conversion at each point of connection will no longer be needed. But, due to the lack of universally accepted standards and technological advancements, the implementation of DC microgrids is still limited to very small-scale usage. The unavailability of an efficient and reliable protection system is one such issue that is hindering the implementation of DC microgrids on a larger scale. Therefore, a thorough examination of the several DC microgrid protection difficulties and challenges is necessary. Thus the purpose of this article is to provide a comprehensive analysis of the protection challenges, and the currently available protection schemes for DC microgrids and to highlight the gaps for future research to enable the development of a more reliable and efficient protection system.

13 May 2016 in Electric Power Components and Systems
Verified
Journal Article
Closed access
OGOm Hari Gupta
Om Hari Gupta
MTManoj Tripathy
Manoj Tripathy
This article presents a fault detection and classification scheme for a series-compensated transmission line that is based on post-fault superimposed energy. The derivations of the scheme presented in this article are obtained with consideration of both the real and reactive components of the power system. However, the criterion depends only on the real components of the power system. For a forward fault, superimposed energy is negative, whereas it is positive for a reverse fault. If the relays of both ends detect forward fault, it is an internal fault; else, it is an external fault. The magnitude of superimposed energy depends on the fault type, location, and resistance, which makes it difficult to classify the type of fault as a fixed threshold cannot be set. Therefore, to classify the type of fault, energy coefficients have been introduced that depend on the superimposed energy measured at the relay. To test the capability of the superimposed energy based scheme, the test system has been simulated in PSCAD/EMTDC (Manitoba HVDC Research Centre) and an algorithm has been implemented in MATLAB (The MathWorks, Natick, Massachusetts, USA). Results proved that the scheme is accurate and robust against different system conditions and uncertainties.

17 January 2018 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
OGOm Hari Gupta
Om Hari Gupta
MTManoj Tripathy
Manoj Tripathy
The fault component power and energy‐based relaying schemes find limitation during the double phase to ground faults due to the effect of mutual coupling. In this study, a pilot relaying scheme for series and shunt‐compensated transmission lines is introduced which is based on incremental reactive power coefficients (IRPCs). The IRPC of a phase is defined as the ratio of integrated incremental reactive power (IIRP) to the maximum magnitude of IIRP among all three phases. If IRPC of any phase is found less than −0.5, the internal fault is detected else if none of the phases has IRPC less than −0.5, the fault is an external fault. The algorithm will start only if the incremental differential current of any phase is found >50% of pre‐fault differential current. The proposed scheme has various advantages including universal applicability to protect the series and shunt‐compensated transmission lines. The offline and real‐time simulations are carried out to investigate the performance of the proposed scheme under different operating conditions. The scheme is robust and accurate for all the conditions. Further, the performance of the proposed scheme is superior to the recently proposed schemes.

9 December 2016 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
OGOm Hari Gupta
Om Hari Gupta
MTManoj Tripathy
Manoj Tripathy