This paper explores the application of parametric design principles using optimization methods to enhance seismic design of a 4-story reinforced concrete building. Through a detailed case study, the paper demonstrates the versatility of Simulated Annealing on building an algorithm that is based on FEA analysis potentially linked with parametric design but at the same time use a stochastic optimization method to tackle the problem. The introduction starts by a quick brief overview of parametric design and visual programming since in the recent years are becoming more and more common to architects and engineers for their user-friendly interface where users can build scripts connecting blocks that represent functions. At this point it is important to emphasize some parametric design concepts, the previous studies on parametric design in related fields and therefore the corresponding key principles of Grasshopper in structural design. The methodology used is referred to the algorithm that involves the use of Simulated Annealing to iterate the different models and analysis by minimizing the torsional eccentricity on each floor after each iteration. Detailed explanation of how Grasshopper was employed in the design process and the visualization of the parametric design iterations are given. The results demonstrate the effectiveness of this approach, by presenting several design iterations which allow the engineers to have an optimal response against the seismic events just by arranging the dimensions and directions of columns, without changing the structural form. A discussion follows the interpretation of results based on the advantages and challenges of using Grasshopper for structural seismic response and an exploration of potential real-world applications. The main conclusion derives the summary of key findings, the implications of the study for future preliminary design concepts of the represented typology and also the encouragement for further research in the field of parametric design.
16 October 2024 in FORUM A+P Interdisciplinary Journal of Architecture and Built Environment
The recycling and reuse of wood have gained importance as strategies for reducing construction waste, lowering costs, and promoting circular practices in the built environment. This study evaluates the performance of recycled wood particle/epoxy composites (WPECs) for façade applications by prototyping panels produced from granulated degraded wood bonded with epoxy resin and coated with intumescent fire-retardant paint. The panels were design to meet standards for ventilated façade applications in accordance with EN 310-93 and ASTM D1037-06a and relevant building codes for facade cladding. Three replicates of each panel type were tested under controlled laboratory conditions to assess water absorption, equilibrium moisture content, capillarity, fire resistance, and mechanical performance. Moisture measurements were performed at immersion and drying intervals of 12, 24, 36, 72, and 120 h for four WPEC types manufactured with pine, beech, oak, and olive fibers. Statistical evaluation using SPSS (one-way and two-way ANOVA) confirmed significant species effects across most parameters. Results indicated that olive and oak WPECs provided the highest dimensional stability under moisture exposure, with olive additionally demonstrating superior compressive strength (35.45 MPa) and hardness (˂10,000 N). Pine and beech WPECs exhibited intermediate bending strength (≈10 MPa) and elasticity, while oak contributed stable swelling values despite lower strength. Fire resistance tests suggested relative improvements, although further standardized evaluation is needed. Collectively, olive and oak WPECs emerged as the most promising façade materials, combining durability, mechanical strength, and sustainability.
In recent years, the recycling and reuse of wood have become increasingly important for reducing construction waste, lowering costs, and promoting a circular economy in the built environment. This study explores the potential of recycled wood composites by prototyping panels made of granulated wood combined with epoxy resin and coated with intumescent fire-retardant paint. The panels were tested for water absorption, equilibrium moisture content, capillarity, and fire resistance under controlled conditions. Measure-ments were carried out over intervals of 12, 24, 36, 72, and 120 hours to assess differences among four species: pine, beech, oak, and olive. Results highlight that wood anatomy and structure play a decisive role in both moisture transport and fire behavior. Olive and oak demonstrated the most stable performance, with reduced dimensional changes and high-er resistance to ignition, while beech showed balanced properties, and pine exhibited greater fluctuations unless treated. These findings suggest that olive and oak are the most suitable candidates for ventilated façade applications, with beech serving as a viable compromise and pine as an economical choice under protective measures. The study con-tributes to a broader understanding of recycled timber performance and its practical im-plications for sustainable architectural design.