Stress cardiovascular magnetic resonance (CMR) perfusion imaging is a promising modality for the evaluation of coronary artery disease (CAD) due to high spatial resolution and absence of radiation. Semi-quantitative and quantitative analysis of CMR perfusion are based on signal-intensity curves produced during the first-pass of gadolinium contrast. Multiple semi-quantitative and quantitative parameters have been introduced. Diagnostic performance of these parameters varies extensively among studies and standardized protocols are lacking. This study aims to determine the diagnostic accuracy of semi- quantitative and quantitative CMR perfusion parameters, compared to multiple reference standards. Pubmed, WebOfScience, and Embase were systematically searched using predefined criteria (3272 articles). A check for duplicates was performed (1967 articles). Eligibility and relevance of the articles was determined by two reviewers using pre-defined criteria. The primary data extraction was performed independently by two researchers with the use of a predefined template. Differences in extracted data were resolved by discussion between the two researchers. The quality of the included studies was assessed using the ‘Quality Assessment of Diagnostic Accuracy Studies Tool’ (QUADAS-2). True positives, false positives, true negatives, and false negatives were subtracted/calculated from the articles. The principal summary measures used to assess diagnostic accuracy were sensitivity, specificity, andarea under the receiver operating curve (AUC). Data was pooled according to analysis territory, reference standard and perfusion parameter. Twenty-two articles were eligible based on the predefined study eligibility criteria. The pooled diagnostic accuracy for segment-, territory- and patient-based analyses showed good diagnostic performance with sensitivity of 0.88, 0.82, and 0.83, specificity of 0.72, 0.83, and 0.76 and AUC of 0.90, 0.84, and 0.87, respectively. In per territory analysis our results show similar diagnostic accuracy comparing anatomical (AUC 0.86(0.83–0.89)) and functional reference standards (AUC 0.88(0.84–0.90)). Only the per territory analysis sensitivity did not show significant heterogeneity. None of the groups showed signs of publication bias. The clinical value of semi-quantitative and quantitative CMR perfusion analysis remains uncertain due to extensive inter-study heterogeneity and large differences in CMR perfusion acquisition protocols, reference standards, and methods of assessment of myocardial perfusion parameters. For wide spread implementation, standardization of CMR perfusion techniques is essential. CRD42016040176 .
15 May 2019 in The International Journal of Cardiovascular Imaging
To demonstrate the potential for differentiating normal and diseased myocardium without Gadolinium using rest and stress T1-mapping. Patients undergoing 1.5T magnetic resonance imaging (MRI) as part of clinical work-up due to suspicion of coronary artery disease (CAD) were included. Adenosine stress perfusion MRI and late gadolinium enhancement (LGE) imaging were performed to identify ischemic and infarcted myocardium. Patients were retrospectively categorized into an ischemic, infarct and control group based on conventional acquisitions. Patient with both ischemic and infarcted myocardium were excluded. A total of 64 patients were included: ten with myocardial ischemia, 15 with myocardial infarction, and 39 controls. A native Modified Look-Locker Inversion Recovery (MOLLI) T1-mapping acquisition was performed at rest and stress. Pixel-wise myocardial T1-maps were acquired in short-axis view with inline motion-correction. Short-axis T1-maps were manually contoured using conservative septal sampling. Regions of interest were sampled in ischemic and infarcted areas detected on perfusion and LGE images. T1 reactivity was calculated as the percentage difference in T1 values between rest and stress. Remote myocardium was defined as myocardium without defects in the ischemic and infarcted group whereas normal myocardium is found in the control group only. Native T1-values were significantly higher in infarcted myocardium in rest and stress [median 1044 ms (interquartile range (IQR) 985–1076) and 1053 ms (IQR 989–1088)] compared to ischemic myocardium [median 961 ms (IQR 939–988) and 958 ms (IQR 945–988)]. T1-reactivity was significantly lower in ischemic and infarcted myocardium [median 0.00% (IQR − 0.18 to 0.16) and 0.41% (IQR 0.09–0.86)] compared to remote myocardium [median 3.54% (IQR 1.48–5.78) and 3.21% (IQR 1.95–4.79)]. Rest-stress T1-mapping is able to distinguish between normal, ischemic, infarcted and remote myocardium using native T1-values and T1-reactivity, and holds potential as an imaging biomarker for tissue characterization in MRI.
Background. Caffeine is one of the most widely consumed stimulants worldwide. It is a well-recognized antagonist of adenosine and a potential cause of false-negative functional measurements during vasodilator myocardial perfusion. The aim of this systematic review is to summarize the evidence regarding the effects of caffeine intake on functional measurements of myocardial perfusion in patients with suspected coronary artery disease. Pubmed, Web of Science, and Embase were searched using a predefined electronic search strategy. Participants—healthy subjects or patients with known or suspected CAD. Comparisons—recent caffeine intake versus no caffeine intake. Outcomes—measurements of functional myocardial perfusion. Study design—observational. Fourteen studies were deemed eligible for this systematic review. There was a wide range of variability in study design with varying imaging modalities, vasodilator agents, serum concentrations of caffeine, and primary outcome measurements. The available data indicate a significant influence of recent caffeine intake on cardiac perfusion measurements during adenosine and dipyridamole induced hyperemia. These effects have the potential to affect the clinical decision making by re-classification to different risk-categories.
24 November 2017 in The International Journal of Cardiovascular Imaging
Caffeine is an adenosine receptor antagonist and a possible cause of inadequate stress perfusion. Splenic switch-off (SSO) and splenic rest-stress T1-mapping have been proposed as indicators of stress adequacy during perfusion cardiac magnetic resonance (CMR). We compared myocardial rest-stress T1-mapping with SSO and splenic rest-stress T1-mapping in patients with and without recent coffee intake. We analyzed 344 consecutive patients suspected of myocardial ischemia with adenosine perfusion CMR. All 146 normal CMR studies with a normal T1-rest of the myocardium, used as standard of reference, were included and divided in two groups. 22 patients accidentally ingested coffee < 4 h before CMR, compared to control group of 124 patients without self-reported coffee intake. Two independent readers graded SSO visually. T1-reactivity (ΔT1) was defined as percentual difference in T1-rest and T1-stress. Follow-up data were extracted from electronic patients records. In patients with recent coffee intake SSO was identified in 96%, which showed no significant difference with SSO in controls (94%, p = 0.835), however event rates were significantly different (13.6 and 0.8%, respectively (p < 0.001), median FU 17 months). Myocardial ΔT1 in the coffee group (− 5.2%) was significantly lower compared to control (+ 4.0%, p < 0.001), in contrast to the splenic ΔT1 (− 3.7 and − 4.0%, p = 0.789). The splenic T1-mapping results failed to predict false negative results. SSO and splenic rest-stress T1-mapping are not reliable indicators of stress adequacy in patients with recent coffee intake. Therefore, the dark spleen sign does not indicate adequate myocardial stress in patients with recent caffeine intake. Myocardial rest-stress T1-mapping is an excellent indicator of stress adequacy during adenosine perfusion CMR.