Given NMN’s (Nicotinamide mononucleotide, NMN) potential pet health benefits and wide use in pet foods, the lack of standardized detection methods hinders quality control. This study developed and validated a simple, rapid HPLC (High-Performance Liquid Chromatography, HPLC) method for NMN determination in pet foods. The method showed good linearity (5–500 μg/mL), LOD (1.0 mg/kg), LOQ (2.0 mg/kg), precision, stability, reproducibility, and spiked recoveries (97.3–109%, RSD < 6.0%). And most tested commercial samples met the standards. This method is simple, efficient, and accurate, supporting pet food NMN detection, quality control, regulation, and pet health protection.