Background: Atrial septal defect type II (ASD), according to current standards, is closed percutaneously usually after the child has reached the age of 4-5 years. There are limited data regarding such treatment in smaller infants. Aims: To evaluate feasibility, safety and efficacy of percutaneous ASD closure in children under 3 years of age. Methods: Overall group of 149 children < 3 years with hemodynamically significant ASD, who underwent effective transcatheter ASD closure in one tertiary center between 1999 and 2014 were included. Mean procedural age of treated children was 2,2 years and weight 12,5 kg. In all nitinol wire mesh devices were applied (mostly Amplatzer Septal Occluders). ASD was closed by standard technique (except few cases when left disc of implant was inserted initially into right pulmonary vein to prevent oblique position of the device). Complications related to the procedure were divided into major and minor ones. Results: There were 97 children with a single ASD and 52 with double/multiple ASD. No death, no implant embolization, and one major complications occurred during procedure and in follow-up. ASD was completely closed in all but 8 patients with double/multiple ASD. Right ventricle diameter normalization occurred in all during 1 year follow-up. In majority of the patients in follow-up an acceleration of physical development and resolution of accompanying morbidity was observed. Conclusions: Percutaneous ASD device closure can be performer safely in children below 3 years of age with low risk of complication during and after the procedure. Background: Atrial septal defect type II (ASD), according to current standards, is closed percutaneously usually after the child has reached the age of 4-5 years. There are limited data regarding such treatment in smaller infants. Aims: To evaluate feasibility, safety and efficacy of percutaneous ASD closure in children under 3 years of age. Methods: Overall group of 149 children < 3 years with hemodynamically significant ASD, who underwent effective transcatheter ASD closure in one tertiary center between 1999 and 2014 were included. Mean procedural age of treated children was 2,2 years and weight 12,5 kg. In all nitinol wire mesh devices were applied (mostly Amplatzer Septal Occluders). ASD was closed by standard technique (except few cases when left disc of implant was inserted initially into right pulmonary vein to prevent oblique position of the device). Complications related to the procedure were divided into major and minor ones. Results: There were 97 children with a single ASD and 52 with double/multiple ASD. No death, no implant embolization, and one major complications occurred during procedure and in follow-up. ASD was completely closed in all but 8 patients with double/multiple ASD. Right ventricle diameter normalization occurred in all during 1 year follow-up. In majority of the patients in follow-up an acceleration of physical development and resolution of accompanying morbidity was observed. Conclusions: Percutaneous ASD device closure can be performer safely in children below 3 years of age with low risk of complication during and after the procedure.
Objectives. Patent ductus arteriosus (PDA) in elderly patients is an uncommon anomaly, and the duct itself is often calcified and fragile; therefore, transcatheter closure is more difficult. The aim is to analyse periprocedural and one-year follow-up results of transcatheter closure of PDA in such patients. Methods and results. Retrospective analysis of 33 elective patients aged ≥55 years (median 63; 56–85; 29 women), in whom PDA was closed percutaneously between 2002 and 2018 in two tertiary centres. All but three patients were symptomatic, with most in NYHA II (n = 14) and III (n = 11) class; pulmonary hypertension (n = 22), arterial hypertension (n = 22), duct calcifications (n = 17), atrial fibrillation (n = 15), significant mitral regurgitation (n = 5), and decompensated renal failure (n = 2) were observed. Different devices were applied depending on PDA morphology; nitinol wire mesh occluders with symmetrical articulating discs have been the most used in recent years (n = 11). Follow-up was conducted at an outpatient clinic (28/33 patients). The procedure was successful in all patients. There was one embolisation, followed by implantation of a larger device. No major complications were noted. A small residual shunt was present in echocardiography in one patient after one year. NYHA class improved in all but two patients (with multiple comorbidities). Conclusions. Transcatheter PDA closure in elderly patients is safe and efficient with a high complete closure rate and few complications. Amplatzer duct occluder type II is an attractive device in such patients.