Sybrand Johannes van der Spuy

Prof. Sybrand Johannes van der Spuy

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2015 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
NFNeil Fourie
Neil Fourie
SSSybrand Johannes van der Spuy
Sybrand Johannes van der Spuy
TBT. W. von Backström
T. W. von Backström

1 October 2018 in Journal of Fluids and Structures
Verified
Journal Article
Closed access
CPChristian D. Peters
Christian D. Peters
SSSybrand Johannes van der Spuy
Sybrand Johannes van der Spuy
DEDaniel N.J. Els
Daniel N.J. Els
JKJörg Kuhnert
Jörg Kuhnert

16 June 2014
Verified
Conference Paper
Closed access
PDF file
FLFrancois G. Louw
Francois G. Louw
TBTheodor W. von Backström
Theodor W. von Backström
SSSybrand Johannes van der Spuy
Sybrand Johannes van der Spuy
Large axial flow fans are used in forced draft air cooled heat exchangers (ACHEs). Previous studies have shown that adverse operating conditions cause certain sectors of the fan, or the fan as a whole to operate at very low flow rates, thereby reducing the cooling effectiveness of the ACHE. The present study is directed towards the experimental and numerical analyses of the flow in the vicinity of an axial flow fan during low flow rates. This is done to obtain the global flow structure up and downstream of the fan. A near-free-vortex fan, designed for specific application in ACHEs, is used for the investigation. Experimental fan testing was conducted in a British Standard 848, type A fan test facility, to obtain the fan characteristic. Both steady-state and time-dependent numerical simulations were performed, depending on the operating condition of the fan, using the Realizable k-ε turbulence model. Good agreement is found between the numerically and experimentally obtained fan characteristic data. Using data from the numerical simulations, the time and circumferentially averaged flow field is presented. At the design flow rate the downstream fan jet mainly moves in the axial and tangential direction, as expected for a free-vortex design criteria, with a small amount of radial flow that can be observed. As the flow rate through the fan is decreased, it is evident that the down-stream fan jet gradually shifts more diagonally outwards, and the region where reverse flow occur between the fan jet and the fan rotational axis increases. At very low flow rates the flow close to the tip reverses through the fan, producing a small recirculation zone as well as swirl at certain locations upstream of the fan.

6 July 2015 in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Verified
Journal Article
Closed access
SSSybrand Johannes van der Spuy
Sybrand Johannes van der Spuy
TBTheodor W von Backström
Theodor W von Backström
Modelling air-cooled condensers (ACCs) incorporating hundreds of fans, necessitates the use of simplified fan models when performing a computational fluid dynamics (CFD) analysis of the condenser. The perimeter fans in these ACCs are subjected to distorted inlet flow conditions. This paper compares the accuracy of three different simplified fan models and proposes an improved model, based on numerical and experimental results from representative fan configurations. Three different fan configurations are tested as perimeter fans in a three-fan test facility, and their results compared to CFD results. The experimental evaluation by particle image velocimetry (PIV) reveals the shape of the velocity profiles immediately upstream of the perimeter fan. The accuracy of the CFD-predicted flow field directly upstream of the perimeter fan varies according to the model used to represent the fan as well as the configuration of the specific perimeter fan. The paper indicates a discrepancy of as much as 30% between experimental and simulated volumetric effectiveness values for a specific simulation model and fan configuration. The standard and extended actuator disc fan models perform better than the pressure jump model in predicting the volumetric effectiveness of the perimeter fans, and the extended actuator disc model performs best at predicting fan inlet velocity profiles.

3 April 2019 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
RERuan A. Engelbrecht
Ruan A. Engelbrecht
CMChris J. Meyer
Chris J. Meyer
SSSybrand Johannes van der Spuy
Sybrand Johannes van der Spuy

7 December 2018 in Journal of Engineering for Gas Turbines and Power
Verified
Journal Article
Closed access
PDF file
MWMichael B. Wilkinson
Michael B. Wilkinson
SSSybrand Johannes van der Spuy
Sybrand Johannes van der Spuy
TBTheodor W. von Backström
Theodor W. von Backström
An axial flow fan developed in the previous study is tested in order to characterize its performance. The M-fan, a 7.3152 m diameter rotor only axial flow fan was designed to perform well under the challenging operating conditions encountered in air-cooled heat exchangers. Preliminary computational fluid dynamics (CFD) results obtained using an actuator disk model (ADM) as well as a periodic three dimensional model indicate that the fan meets the specified performance targets, with an expected total-to-static efficiency of 59.4% and a total-to-static pressure rise of 114.7 Pa at the operating point. Experimental tests are performed on the M-fan in order to determine its performance across a full range of flow rates. A range of fan configurations are tested in order to ascertain the effect of tip clearance, blade angle, and hub configuration on fan performance. Due to the lack of a suitable facility for testing a large diameter fan, a scaled 1.542 m diameter model is tested on the ISO 5801 type A fan test facility at Stellenbosch University. A Reynolds-averaged Navier–Stokes CFD model representing the M-fan in the test facility is also developed in order to provide additional insight into the flow field in the vicinity of the fan blades. The results of the CFD model will be validated using the experimental data obtained. Both the CFD results and the experimental data obtained are compared to the initial CFD results for the full scale fan, as obtained in the previous study, by means of fan scaling laws. Experimental data indicate that the M-fan does not meet the pressure requirement set out in the initial study at the design blade setting angle of 34 deg. Under these conditions, the M-fan attains a total-to-static pressure rise of 102.5 Pa and a total-to-static efficiency of 56.4%, running with a tip gap of 2 mm. Increasing the blade angle is shown to be a potential remedy, improving the total-to-static pressure rise and efficiency obtained at the operating point. The M-fan is also shown to be highly sensitive to increasing tip gap, with larger tip gaps substantially reducing fan performance. The losses due to tip gap are also shown to be overestimated by the CFD simulations. Both experimental and numerically obtained results indicate lower fan total-to-static efficiencies than obtained in the initial CFD study. Results indicate that the M-fan is suited to its intended application, however, it should be operated with a smaller tip gap than initially recommended and a larger blade setting angle. Hub configuration is also shown to have an influence on fan performance, potentially improving performance at low flow rates.