Ahmed M. Seddik Hassan

Dr. Ahmed M. Seddik Hassan

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AHAhmed M. Seddik Hassan
Ahmed M. Seddik Hassan
RAReham Fathy Ahmed Abd El Aal
Reham Fathy Ahmed Abd El Aal
AFAsmaa Abd Elmoneim Fahmi
Asmaa Abd Elmoneim Fahmi
SASherif Mohamed Ahmed Ali
Sherif Mohamed Ahmed Ali
MAMohamed I. M. Abdelhady
Mohamed I. M. Abdelhady
The research aim is to clarify the effect of courtyard placement, the ratio between length and width, and courtyard orientation on energy consumption in residential buildings in hot and dry climates, to seek planning and designing alternatives for new cities and new residential complexes that are consistent with the environment and climate and save the consumption of energy used in the buildings. The research method was conducted through Design Builder software for simulation purposes. The reference model with the 157.25 m2 which accommodates a central square courtyard measuring 5 m × 5 m, on a residential building model in the New Valley Governorate of Kharga City, Egypt. The courtyard simulation is aimed to determine Less energy consumption inside the different case studies, in 9 courtyard placements The studied alternatives for Courtyard Placement, are (the center of the building, sub facades, and main facades). The different ratios are (1:1, 1.25:1, 1.5:1–1.75:1, 2:1, 2.25:1, 2.5–1). The longitudinal axis of the Courtyard has been oriented to the east–west direction for all placements, and north–south direction for all placements. Also, (orientation angle is Zero), it offered the percentages of better and worst cases in each position of the courtyard. The research findings suggest that the best Placement of the Courtyard that achieved the highest rate of saving of energy consumed inside the used building model was at the southwestern façade, with a saving rate of 18.73%. Then, the Placement of the Courtyard at the northwestern and southeastern facades with a saving rate of 17.91%, with a length-to-width ratio (2.5:1) if the longitudinal axis of the Courtyard is oriented in the north–south direction, Through the study, we conclude that the placement and orientation of the courtyard and its regular formation have contributed to rationalizing energy consumption in residential buildings, the study reached some important standards that could represent a methodological framework for designing contemporary residential buildings with an energy-efficient inner courtyard.

1 March 2024 in Journal of Architectural Engineering
Verified
Journal Article
Closed access
AAAimen H. Abo Alela
Aimen H. Abo Alela
Bahaa ElboshyBahaa Elboshy
Bahaa Elboshy
AHAhmed M. Seddik Hassan
Ahmed M. Seddik Hassan
ASAyman S.Mohamed
Ayman S.Mohamed
ESeman nabih shaqour
eman nabih shaqour

1 March 2025 in Journal of Architectural Engineering
Verified
Journal Article
Closed access
ESeman nabih shaqour
eman nabih shaqour
AHAhmed M. Seddik Hassan
Ahmed M. Seddik Hassan
AAAimen H. Abo Alela
Aimen H. Abo Alela
ASAyman S.Mohamed
Ayman S.Mohamed

10 October 2025 in Energies
Verified
Journal Article
Open access
PDF file
ESeman nabih shaqour
eman nabih shaqour
ISIslam Al shafei
Islam Al shafei
Ala AbutaqaAla Abutaqa
Ala Abutaqa
Ahmed SenouciAhmed Senouci
Ahmed Senouci
AHAhmed M. Seddik Hassan
Ahmed M. Seddik Hassan
In this study, the energy performance of traditional, modern, and insulated wall assemblies in a heritage residential building in Al Salt city, Jordan, is evaluated using the simulation software DesignBuilder version 7.0.2.004. The case study compares the thermal behavior of traditional thick limestone walls, modern reinforced concrete and block-based walls, and contemporary insulated systems under local climatic conditions. The results show that traditional stone walls exhibit limited energy efficiency and require insulation to meet contemporary standards. However, they perform better than modern concrete walls based on their thermal mass. While concrete walls with inadequate insulation exhibit the poorest performance and are associated with significantly higher energy demand and CO2 emissions, insulated wall systems that combine stone with insulation layers demonstrate the best thermal performance and achieve substantial reductions in energy use and environmental impact. These findings emphasize the feasibility of upgrading heritage buildings through the integration of modern insulated wall assemblies, which can lead to considerable energy savings and a lowered carbon footprint while simultaneously keeping the architectural identity and cultural value.