Alex G Nwosu

Mr. Alex G Nwosu


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2025 in Buildings
Verified
Journal Article
Open access
PDF file
ANAlex G Nwosu
Alex G Nwosu
BZBello Mahmud Zailani
Bello Mahmud Zailani
JHJames Gregory Hunter
James Gregory Hunter
Baltimore’s historic row-home neighborhoods face escalating risks to energy, heat, and durability under intensifying climate stress. This study develops a Housing-Performance Atlas that quantifies multi-hazard performance for eight representative archetypes using DesignBuilder/EnergyPlus Version 7.3.1.003, under Baltimore TMY3 boundary conditions. Performance is evaluated across the following four adaptation domains: energy use intensity, passive survivability during 72 h outage events, roof overheating exposure (>150 °F exceedance hours), and material service life derived from ISO 15686 and synthesized into Lean and Full Deficit Indices for comparative resilience ranking. Results show that EUI ranged from 46.7 to 67.6 kBtu ft−2·yr−1, survivability from 0 to 23 h, and roof temperatures exceeded 150 °F for 150–210 h, shortening roof service life by up to 10 years. Composite Lean and Full Deficit Indices ranged 7.8–92.4, ranking Model 5 (end-unit, flat roof, two-story with basement) as the most resilient configuration and Model 8 (end-unit, pitched roof, three-story above-grade) as the least resilient due to compounded overheating and energy losses. Heat-related domains accounted for nearly 70% of overall resilience deficits, confirming thermal safety and roof reflectivity as retrofit priorities. The Housing-Performance Atlas establishes a reproducible diagnostic framework linking simulation, service life, and resilience metrics to guide cost-effective, climate-responsive retrofits in Baltimore’s aging urban housing stock.

4 November 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
ANAlex G Nwosu
Alex G Nwosu
BZBello Mahmud Zailani
Bello Mahmud Zailani
JHJames Gregory Hunter
James Gregory Hunter
Baltimore’s historic row-home neighborhoods face escalating risks to energy, heat, and durability under intensifying climate stress. This study develops a Housing-Performance Atlas that quantifies multi-hazard performance for eight representative archetypes using DesignBuilder/EnergyPlus under Baltimore TMY3 boundary conditions. Performance is evaluated across four adaptation domains: energy use intensity, passive survivability during 72-h outage events, roof overheating exposure (>150 °F exceedance hours), and material service life derived from ISO 15686 and synthesized into Lean and Full Deficit Indices for comparative resilience ranking. Results show that EUI ranged from 46.7 to 67.6 kBtu ft⁻²·yr⁻¹, survivability from 0 to 23 hours, and roof temperatures exceeded 150 °F for 150–210 hours, shortening roof service life by up to 10 years. Composite Lean and Full Deficit Indices ranged 7.8–92.4, ranking Model 5 (end-unit, flat roof, two-story with basement) as the most resilient configuration and Model 8 (end-unit, pitched roof, three-story above-grade) as the least resilient due to compounded overheating and energy losses. Heat-related domains accounted for nearly 70 % of overall resilience deficits, confirming thermal safety and roof reflectivity as retrofit priorities. The Housing-Performance Atlas establishes a reproducible diagnostic framework linking simulation, service life, and resilience metrics to guide cost-effective, climate-responsive retrofits in Baltimore’s aging urban housing stock.

1 July 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ANAlex G Nwosu
Alex G Nwosu
Mehdi ShokouhianMehdi Shokouhian
Mehdi Shokouhian
JHJames Gregory Hunter
James Gregory Hunter
As cities increasingly rely on retrofitting aging housing stock to achieve decarbonization and climate resilience goals, a critical gap remains in assessing whether buildings are viable candidates for retrofit prior to detailed design. This study proposes a constructability-based pre-design screening framework for evaluating retrofit feasibility in legacy masonry row homes using digital inspection data. The framework introduces a dual-index system comprising a Retrofit Feasibility Index (RFI), which quantifies technical readiness across structural integrity, envelope condition, moisture exposure, utilities, durability, and constructability, and an Economic Rehabilitation Index (ERI), which captures relative cost burden across major retrofit drivers. A key innovation of the study is the integration of floor-resolved diagnostics, which reveal significant vertical heterogeneity in retrofit feasibility that is not captured by conventional whole-building assessments. An application to a case study row home demonstrates that upper floors are highly feasible, while ground-level moisture-driven deterioration and structural constraints significantly reduce overall viability, leading to a targeted retrofit classification. The findings further establish moisture as a primary degradation mechanism that influences both structural performance and economic costs. The framework enables rapid, evidence-based retrofit triage under uncertainty, bridging the gap between digital inspection technologies and constructability-driven decision-making in aging urban housing systems.