Conventional mass spectrometry does not distinguish between enantiomers, or mirror-image isomers. Here we report a technique to break the chiral symmetry and to differentiate enantiomers by inducing directional rotation of chiral gas-phase ions. Dual alternating current excitations were applied to manipulate the motions of trapped ions, including the rotation around the center of mass and macro movement around the center of the trap. Differences in collision cross section were induced, which could be measured by ion cloud profiling at high resolutions above 10,000. High-field ion mobility and tandem mass spectrometry analyses of the enantiomers were combined and implemented by using a miniature ion trap mass spectrometer. The effectiveness of the developed method was demonstrated with a variety of organic compounds including amino acids, sugars, and several drug molecules, as well as a proof-of-principle ligand optimization study for asymmetric hydrogenation.
Background/Objectives: Clozapine remains the gold standard for treatment-resistant schizophrenia. However, its narrow therapeutic window and risk of severe side effects require close monitoring of both clozapine and its primary metabolite, norclozapine. Existing therapeutic drug monitoring (TDM) methods are limited by delays, high costs, and operational complexity. This study introduces three rapid point-of-care (POC) assays utilizing a miniature mass spectrometer (Mini-MS) to quantify clozapine and norclozapine in plasma, whole blood, and dried blood spots (DBSs), facilitating applications across diverse clinical settings. Methods: The analytical performance of the assay was evaluated for sensitivity, specificity, reproducibility, and correlation with reference methods. Clinical samples from two hospitals were analysed and validated against conventional liquid chromatography tandem mass spectrometry (LC-MS/MS) reference standards at New South Wales Health Pathology (NSWHP) and Tsinghua University laboratories. Results: The Mini-MS assay accurately quantified both analytes within therapeutic ranges across all matrices. Inter-assay coefficients of variation ranged from 7.9 to 14.1% for clozapine and from 1.6 to 14.6% for norclozapine. Accuracy fell between 85 and 117% in plasma and blood extracts. Strong linearity was demonstrated (R2 = 0.98–0.99) over the concentration range of 10–1000 ng/mL. Results from the Mini-MS analysis showed excellent correlations with LC-MS/MS results (r = 0.998). Conclusions: In this proof-of-concept study, the Mini-MS-based POC assays enable rapid, reliable quantification of clozapine and norclozapine, with performance comparable to conventional laboratory methods. This platform supports real-time TDM, facilitating timely dose adjustments, adherence monitoring, and ultimately improving patient outcomes.