Shailesh Jain

Dr. Shailesh Jain


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2025 in Bioinformation
Verified
Journal Article
Open access
LKLalit Kumar
Lalit Kumar
SSSuranjana Sen
Suranjana Sen
DADeepali Agarwal
Deepali Agarwal
MGMegha Gupta
Megha Gupta
KAKhadija Anwaar
Khadija Anwaar
SJShailesh Jain
Shailesh Jain
Implant-supported overdentures have become a widely accepted treatment modality for edentulous patients, offering enhanced retention, stability and comfort compared to conventional complete dentures. Hence, a total of 78 standardized specimens were fabricated and divided into three groups (n = 26 each): Group A (heat-cured PMMA), Group B (CAD/CAM milled resin) and Group C (3D-printed resin). Group B exhibited the lowest surface roughness (0.62 ą 0.12 μm) and microbial adherence (0.41 ą 0.09 OD), followed by Group C (1.25 ą 0.18 μm Ra; 0.68 ą 0.12 OD), while Group A showed the highest values (1.82 ą 0.23 μm Ra; 0.91 ą 0.15 OD). All intergroup comparisons were statistically significant (p < 0.001). A strong positive correlation (r = 0.86, p < 0.001) was observed between surface roughness and microbial adherence. It is concluded that CAD/CAM milled resin offers superior surface smoothness and reduced microbial adherence compared to heat-cured PMMA and 3D-printed resins.

18 June 2025 in Journal of Pharmacy and Bioallied Sciences
Verified
Journal Article
Open access
DKDinesh Kumar
Dinesh Kumar
SHSahba Hassan
Sahba Hassan
MRMadhu S. Ratre
Madhu S. Ratre
SJShailesh Jain
Shailesh Jain
RGRajesh K. Gupta
Rajesh K. Gupta
NANikhil P. Agnihotri
Nikhil P. Agnihotri
Objective: Menopause, the natural biological transition marking the end of a woman’s reproductive years. The study’s main objective is to find an association between menopause age and the thickness of crystal cortical bone at the dental implant site. Methodology: Data were collected from 155 postmenopausal women who have undergone dental implant placement. Results: In the early menopause group (≤45 years), the average bone thickness was 4.2 ± 1.0 mm at the mesial, 3.8 ± 0.9 mm at the mid, and 4.1 ± 1.2 mm at the distal site, with an overall average of 4.0 ± 1.1 mm. In contrast, the late menopause group (>45 years) had an average bone thickness of 3.3 ± 1.1 mm at the mesial, 3.1 ± 1.0 mm at the mid, and 3.2 ± 1.1 mm at the distal site, with an overall average of 3.2 ± 1.0 mm. Conclusion: It is concluded that the age of menopause plays a significant role in determining the thickness of the crestal cortical bone at dental implant sites in postmenopausal women.

3 April 2024 in Journal of Pharmacy and Bioallied Sciences
Verified
Journal Article
Open access
MRMaitreyi Ranjan
Maitreyi Ranjan
HHHany Hameed
Hany Hameed
SJShailesh Jain
Shailesh Jain
YGYogesh Garg
Yogesh Garg
RSRoli Singh
Roli Singh
RJRomesh Jain
Romesh Jain
Introduction: H. pylori are a pathogen of global importance. Gram-negative curved flagellate bacilli are implicated as one of the most trivial complaints of and are associated with peptic ulcer disease gastritis ulcer and gastric malignancy. This study was performed to find out the prevalence of Helicobacter pylori (H. pylori) infection in patients presenting the symptoms related with gastritis with or without chemically known peptic ulcer. Materials and Methods: The study was undertaken with the help of the Christensen and quotes urease test on endoscopic biopsy specimen and correlated with the detection of immunoglobulin IgG in the serum against H. pylori by an ELISA technique. Results: A total of 67 cases were analyzed in which 29 (43%) cases were positive for H. pylori. The endoscopic findings of acid peptic diseases show 21 (31.4%) cases of stomach ulcer, and 3 (4.5%) have esophagitis, whereas 43 (64.1%) have nonulcer dyspepsia. There is strong positive association between the urease tesr and ELISA test. Conclusion: The urease test is a quick and inexpensive test with high specificity and sensitivity, but since it is an invasive test, it has reduced patient compliance.

18 June 2025 in Journal of Pharmacy and Bioallied Sciences
Verified
Journal Article
Open access
SHSahba Hassan
Sahba Hassan
NPNikhil Prakash
Nikhil Prakash
SDSurabhi Duggal
Surabhi Duggal
YGYogesh Garg
Yogesh Garg
SJShailesh Jain
Shailesh Jain
SASyed M. Ahamed
Syed M. Ahamed
Background: Advancements in additive manufacturing, particularly 3D printing, have revolutionized the field of dental prosthetics. Recently, 4D printing, which incorporates time-responsive materials, has emerged as a potential game-changer. This study aims to compare the wear resistance of 3D-printed and 4D-printed dental prosthetics to evaluate the clinical applicability of these innovative technologies. Materials and Methods: Dental prosthetics were fabricated using both 3D printing (polyetheretherketone, PEEK) and 4D printing (shape-memory polymer composites). A total of 40 prosthetics (20 per group) were subjected to wear simulation using a chewing simulator with a load of 50 N at 1 Hz for 100,000 cycles. Surface roughness (Ra) and volumetric loss (mm≥) were measured pre- and post-simulation using 3D laser scanning and confocal microscopy. Statistical analysis was performed using an independent t-test to compare the mean wear resistance between the two groups. Results: The 4D-printed prosthetics exhibited significantly lower volumetric loss (mean: 0.34 ± 0.08 mm≥) compared to the 3D-printed prosthetics (mean: 0.76 ± 0.12 mm≥, P < 0.01). Surface roughness analysis revealed a smaller increase in Ra for 4D-printed prosthetics (from 0.22 ± 0.03 μm to 0.28 ± 0.05 μm) compared to 3D-printed prosthetics (from 0.24 ± 0.04 μm to 0.41 ± 0.06 μm, P < 0.01). Conclusion: The study demonstrates that 4D-printed dental prosthetics possess superior wear resistance compared to 3D-printed prosthetics, highlighting their potential for enhanced longevity and clinical performance in restorative dentistry. Future studies should focus on long-term in vivo evaluations and material optimization to further validate these findings.

31 October 2025 in Bioinformation
Verified
Journal Article
Open access
SBSmritashree Baruah
Smritashree Baruah
POPolysmita Ojah
Polysmita Ojah
SNSangita Nath
Sangita Nath
SJShailesh Jain
Shailesh Jain
NANikhil P. Agnihotri
Nikhil P. Agnihotri
SDSurabhi Duggal
Surabhi Duggal
The effect of different ferrule designs on the fracture resistance of endodontically treated maxillary central incisors. Caries-free maxillary central incisors were endodontically treated and divided into five groups (n=12) based on ferrule design. All teeth were restored with prefabricated glass fiber posts, composite cores, and metal crowns, then subjected to compressive loading using a universal testing machine. The group with a 2 mm circumferential ferrule showed the highest fracture resistance, while the group with no ferrule exhibited the lowest. Statistically significant differences were found among most groups, except between Group 2 and Group 3 (p=0.025).

31 January 2026 in Bioinformation
Verified
Journal Article
Open access
SHSahba Hassan
Sahba Hassan
DKDibya Kumari
Dibya Kumari
SJShailesh Jain
Shailesh Jain
NGNishant Gupta
Nishant Gupta
LKLalit Kumar
Lalit Kumar
SDSurabhi Duggal
Surabhi Duggal
The success of dental implants is influenced by the timing of prosthetic loading. Therefore, it is of interest to compare the clinical and radiological outcomes of immediate loading (IL) versus conventional loading (CL) of dental implants supporting fixed prostheses. Hence, a total of 30 patients were randomly assigned to either IL or CL groups. Clinical parameters such as implant stability (measured by Periotest), peri-implant soft tissue health and radiographic marginal bone loss (MBL) were evaluated over a 12-month period. Results indicated that both groups demonstrated high implant survival rates (96.6% IL vs 100% CL), with no statistically significant differences in MBL at 3, 6 and 12 months (p > 0.05). However, IL provided faster functional rehabilitation and patient satisfaction. Thus, we show the clinical viability of immediate loading protocols in appropriately selected cases, without compromising implant stability or bone levels.