Takehiko Kitamori

Prof. Dr. Takehiko Kitamori

Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2015 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YPYuriy Pihosh
Yuriy Pihosh
ITIvan Turkevych
Ivan Turkevych
KMKazuma Mawatari
Kazuma Mawatari
JUJin Uemura
Jin Uemura
YKYutaka Kazoe
Yutaka Kazoe
TKTakehiko Kitamori
Takehiko Kitamori
Efficient photocatalytic water splitting requires effective generation, separation and transfer of photo-induced charge carriers that can hardly be achieved simultaneously in a single material. Here we show that the effectiveness of each process can be separately maximized in a nanostructured heterojunction with extremely thin absorber layer. We demonstrate this concept on WO3/BiVO4+CoPi core-shell nanostructured photoanode that achieves near theoretical water splitting efficiency. BiVO4 is characterized by a high recombination rate of photogenerated carriers that have much shorter diffusion length than the thickness required for sufficient light absorption. This issue can be resolved by the combination of BiVO4 with more conductive WO3 nanorods in a form of core-shell heterojunction, where the BiVO4 absorber layer is thinner than the carrier diffusion length while it’s optical thickness is reestablished by light trapping in high aspect ratio nanostructures. Our photoanode demonstrates ultimate water splitting photocurrent of 6.72 mA cm−2 under 1 sun illumination at 1.23 VRHE that corresponds to ~90% of the theoretically possible value for BiVO4. We also demonstrate a self-biased operation of the photoanode in tandem with a double-junction GaAs/InGaAsP photovoltaic cell with stable water splitting photocurrent of 6.56 mA cm−2 that corresponds to the solar to hydrogen generation efficiency of 8.1%.

26 May 2014 in Small
Verified
Journal Article
Closed access
PDF file
YPYuriy Pihosh
Yuriy Pihosh
ITIvan Turkevych
Ivan Turkevych
KMKazuma Mawatari
Kazuma Mawatari
TATomohiro Asai
Tomohiro Asai
THTakashi Hisatomi
Takashi Hisatomi
TKTakehiko Kitamori
Takehiko Kitamori

25 January 2006 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
YTYo Tanaka
Yo Tanaka
KMKeisuke Morishima
Keisuke Morishima
TSTatsuya Shimizu
Tatsuya Shimizu
AKAkihiko Kikuchi
Akihiko Kikuchi
MYMasayuki Yamato
Masayuki Yamato
TKTakehiko Kitamori
Takehiko Kitamori
Cellular functions are frequently exploited as processing components for integrated chemical systems such as biochemical reactors and bioassay systems. Here, we have created a new cell-based microsystem exploiting the intrinsic pulsatile mechanical functions of cardiomyocytes to build a cellular micropump on-chip using cardiomyocyte sheets as prototype bio-microactuators. We first demonstrate cell-based control of fluid motion in a model microchannel without check valves and evaluate the potential performance of the bio-actuation. For this purpose, a poly(dimethylsiloxane) (PDMS) microchip with a microchannel equipped with a diaphragm and a push-bar structure capable of harnessing collective cell fluid mechanical forces was coupled to a cultured pulsating cardiomyocyte sheet, activating cell-based fluid movement in the microchannel by actuating the diaphragm. Cell oscillation frequency and correlated fluid displacement in this system depended on temperature. When culture temperature was increased, collective cell contraction frequency remained cooperative and synchronous but increased, while displacement was slightly reduced. We then demonstrated directional fluid pumping within microchannels using cantilever-type micro-check valves made of polyimide. A directional flow rate of nL min−1 was produced. This cell micropump system could be further developed as a self-actuated and efficient mechanochemical transducer requiring no external energy sources for various purposes in the future.

13 November 2006 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
YTYo Tanaka
Yo Tanaka
KSKae Sato
Kae Sato
TSTatsuya Shimizu
Tatsuya Shimizu
MYMasayuki Yamato
Masayuki Yamato
TOTeruo Okano
Teruo Okano
TKTakehiko Kitamori
Takehiko Kitamori
Miniaturization of chemical or biochemical systems creates extremely efficient devices exploiting the advantages of microspaces. Although they are often targeted for implanted tissue engineered organs or drug-delivery devices because of their highly integrated systems, microfluidic devices are usually powered by external energy sources and therefore difficult to be used in vivo. A microfluidic device powered without the need for external energy sources or stimuli is needed. Previously, we demonstrated the concept of a cardiomyocyte pump using only chemical energy input to cells as a driver (Yo Tanaka, Keisuke Morishima, Tatsuya Shimizu, Akihiko Kikuchi, Masayuki Yamato, Teruo Okano and Takehiko Kitamori, Lab Chip, 6(3), pp. 362–368). However, the structure of this prototype pump described there included complicated mechanical components and fabricated compartments. Here, we have created a micro-spherical heart-like pump powered by spontaneously contracting cardiomyocyte sheets driven without a need for external energy sources or coupled stimuli. This device was fabricated by wrapping a beating cardiomyocyte sheet exhibiting large contractile forces around a fabricated hollow elastomeric sphere (5 mm diameter, 250 µm polymer thickness) fixed with inlet and outlet ports. Fluid oscillations in a capillary connected to the hollow sphere induced by the synchronously pulsating cardiomyocyte sheet were confirmed, and the device continually worked for at least 5 days in this system. This bio/artificial hybrid fluidic pump device is innovative not only because it is driven by cells using only chemical energy input, but also because the design is an optimum structure (sphere). We anticipate that this device might be applied for various purposes including a bio-actuator for medical implant devices that relies on biochemical energy, not electrical interfacing.

7 March 2002 in Electrophoresis
Verified
Journal Article
Closed access
PDF file
KSKiichi Sato
Kiichi Sato
MYMaho Yamanaka
Maho Yamanaka
HTHiroko Takahashi
Hiroko Takahashi
MTManabu Tokeshi
Manabu Tokeshi
HKHiroko Kimura
Hiroko Kimura
TKTakehiko Kitamori
Takehiko Kitamori

29 January 2007 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
TTTakehiko Tsukahara
Takehiko Tsukahara
AHAkihide Hibara
Akihide Hibara
YIYasuhisa Ikeda
Yasuhisa Ikeda
TKTakehiko Kitamori
Takehiko Kitamori