BADR OTHMAN

Dr. BADR OTHMAN

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2022 in Cureus
Verified
Journal Article
Open access
BOBADR OTHMAN
BADR OTHMAN
TZTalal Zahid
Talal Zahid
Different imaging modalities have been used as preoperative assessment tools since the emergence of dental implants. This study aimed to compare the detection and presence of mental nerve anterior loop in cone beam computed tomography (CBCT) radiograph and panoramic radiograph. A descriptive, retrospective study was done. The optimal sample size was calculated using Epi Info software. According to the study population (795), the sample size was 259 cases which gave 95% power of the study. A previously taken CBCT and digital panoramic radiographs from the database of Taibah University Dental School and Hospital were observed by two trained and calibrated examiners to determine the presence of a mental nerve anterior loop and compare the two modalities. The mean length of the mental nerve anterior loop was also assessed. Mental nerve anterior loops were detected bilaterally in 57.1% and 17.4% using CBCT and panoramic radiographs, respectively. In CBCT, the right side (20.8%) had a higher prevalence of mental nerve anterior loop than the left side (12%). The mental nerve anterior loop was not visible in 49.4% of the cases using a panoramic radiograph, while CBCT gave 10% of cases as not visible. The mental nerve anterior loop average length was 1.8 ± 0.35 mm and the width was 1.7 ± 0.28 mm. The average distance from the mental foramen to the inferior border of the mandible was 12.1 ± 0.87 mm and the average distance from the mental frogmen to the mandibular midline was 25.1 ± 0.68 mm. As differences between CBCT and panoramic radiographs were statistically significant, CBCT is more accurate and reliable. CBCT is recommended to be used as a preoperative assessment tool to minimize nerve injury-related surgical complications during implant placement at the mandibular premolar area.

3 November 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
BOBADR OTHMAN
BADR OTHMAN
NKNasser A. Kadasah
Nasser A. Kadasah
Saudi Arabia’s Vision 2030 places significant emphasis on the health sector, including dental clinics, as a vital contributor to economic growth and the enhancement of quality healthcare services. Patient satisfaction and loyalty, measured through willingness to revisit, serve as key indicators of success in this evolving healthcare landscape. This study evaluates how service quality dimensions influence patient satisfaction and revisit intentions within dental clinics, Aligning with the goals of improving healthcare standards under Vision 2030. A primary data was collected using random sampling method among 236 patients visiting dental clinics, with an age range of 10 to 70 years. The SERVQUAL model was employed to evaluate service quality across five dimensions: tangibility, accountability, responsiveness, assurance, and empathy. T-test and regression analysis were used to analyze the influence of these dimensions on patient satisfaction and willingness to revisit. The average scores for tangibility, accountability, responsiveness, assurance, and empathy were 3.95/5, 2.93/5, 3.04/5, 3.55/5, and 3.08/5, respectively. Responsiveness, assurance, and empathy significantly influenced both patient satisfaction and willingness to revisit, while accountability had a negative impact. The regression analysis revealed that 42.8% of the variation in patient satisfaction and 42.9% in willingness to revisit could be explained by the service quality dimensions. Empathy emerged as a crucial factor, positively impacting patient satisfaction and willingness to revisit. The study highlights the importance of responsiveness, assurance, and empathy in determining patient satisfaction and loyalty in dental clinics. While tangibility was not a significant factor in patient satisfaction, it influenced the willingness to revisit, suggesting that the physical aspects of the clinic play a role in patient loyalty. The findings underscore the need for dental clinics to focus on improving scheduling systems, providing financial assurances, and enhancing personal care to improve patient experiences. This research contributes to the understanding of service quality in dental clinics and provides insights for enhancing patient satisfaction and loyalty, Aligning with the goals of Vision 2030.

22 September 2022 in Cureus
Verified
Journal Article
Open access
BOBADR OTHMAN
BADR OTHMAN
TZTalal Zahid
Talal Zahid
HKHanadi M Khalifa
Hanadi M Khalifa
AAAbdulmajeed Afandi
Abdulmajeed Afandi
NANawaf A Alshehri
Nawaf A Alshehri
SASultan Abdoun
Sultan Abdoun
Radiographic assessment is an important diagnostic tool in dental practice. Cone beam computed tomography (CBCT) is among the most important imaging examinations. By providing multiplanar visualization of the maxillofacial region, CBCT enables practitioners to assess various conditions three-dimensionally. CBCT is utilized in different fields within dentistry, including oral and maxillofacial surgery, endodontics, orthodontics, periodontics, implant dentistry, and others. Having access to accurate 3D images is crucial in implant dentistry. This study aimed to measure the crestal bone height loss and facial alveolar bone thickness in the maxillary anterior teeth using CBCT to investigate its effect on surgical planning for dental implant placement in adult patients. CBCT scans (N = 119) of adults, aged 18-65 years, with bilateral permanent maxillary anterior teeth present were included in this retrospective study. The mean alveolar bone plate thickness and crest bone height loss adjacent to the maxillary anterior teeth were measured and differences were examined. The results suggest that additional care and assessment of dental implant placement should be considered when replacing the permanent lateral incisors and canines. The frequency of fenestrations and dehiscence is higher in older adults. Possible management includes guided bone regeneration or “pink restorative solutions.” CBCT analysis to assess the bone morphology surrounding “hopeless” maxillary anterior teeth is important to ensure proper diagnosis and management, including the use of dental implants.

26 May 2024 in Cureus
Verified
Journal Article
Open access
PDF file
BOBADR OTHMAN
BADR OTHMAN
MAMada K. Al-Arfaj
Mada K. Al-Arfaj
Three-dimensional (3D) printing is an emerging manufacturing technology in dentistry with a range of applications. Digital dentistry presented in cone beam CT scan radiographs is a revolution that improved surgical outcomes by optimizing accurate diagnosis and analysis of the surgical sites before surgery. A periodontist can modify the treatment plan, surgical techniques, and incision design based on bone defects seen on cone beam CT scans. Block grafting has been a technique of choice when wound stability is required for guided bone regeneration. There was no significant difference between the different surgical procedures for reconstruction and choice should be given to the simpler and less invasive procedure. A xenograft or allograft block can work as an alternative to the autogenous bone block to reduce the surgery time and patient morbidity. Preparation and shaping of block graft during surgery time to match the defect shape can prolong the operative time, reduce the treatment success, and increase postoperative complications. In this case report, a sterilized 3D-printed mandibular jaw was utilized to visualize the defect size and shape. A bovine xenograft block was then prepared, shaped, and adapted on the 3D-printed jaw 30 minutes before the surgery. The block graft was then transferred and well-fitted on the surgical defect. Handling experience was greater and surgery time and postoperative pain were reduced.

19 October 2026 in The Saudi Dental Journal
Verified
Journal Article
Open access
PDF file
BOBADR OTHMAN
BADR OTHMAN
Immediate implant placement in mandibular molar sockets can shorten treatment and reduce the number of surgical interventions, but the anatomy of the posterior mandible may limit implant positioning and increase surgical risk. This study evaluated six cone-beam computed tomography (CBCT)-derived anatomical parameters in mandibular first and second molars. This retrospective cross-sectional study included 25 CBCT scans from 25 adults, providing 100 molar sites (#36, #37, #46, and #47). Buccal bone thickness, crestal bone width, crestal bone height loss, vertical bone height, root apex-to-inferior alveolar canal (IAC) distance, and interradicular distance were measured. The data were analyzed using 2 × 2 repeated-measures analyses of variance with molar type and side as within-subject factors. Pairwise comparisons were Holm-adjusted. Inter-examiner reliability was evaluated using intraclass correlation coefficients. Inter-examiner reliability was excellent for all parameters (ICC range, 0.907–0.988). Second molars had greater buccal bone thickness (mean difference, 0.352 mm; 95% CI, 0.186–0.518; p < 0.001) and crestal bone width (0.786 mm; 95% CI, 0.367–1.205; p = 0.001). First molars had greater vertical bone height (1.724 mm; 95% CI, 1.050–2.398; p < 0.001), root apex-to-IAC distance (0.802 mm; 95% CI, 0.261–1.343; p = 0.005), and interradicular distance (0.924 mm; 95% CI, 0.655–1.193; p < 0.001). Crestal bone height loss did not differ significantly by molar type. Mandibular first and second molars demonstrated distinct CBCT-derived anatomical patterns in this selected dentate sample. These measurements may be informative for preoperative anatomical assessment. Their value for selecting implant dimensions or osteotomy positions, or predicting clinical outcomes, was not evaluated.

20 July 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
BOBADR OTHMAN
BADR OTHMAN
Background/Objectives: Accurate estimation of augmentation volume is essential for successful maxillary sinus augmentation planning. Manual CBCT-derived volumetric calculations remain time-consuming and operator-dependent. Artificial intelligence (AI)-assisted volumetric estimation may provide a standardized and reproducible alternative. This study evaluated the agreement and reliability of an AI-assisted volumetric estimation tool compared with CBCT-derived manually calculated augmentation volumes for sinus augmentation planning. Methods: A retrospective comparative study was conducted on 60 CBCT scans obtained from patients undergoing implant treatment planning. Radiographic measurements included bone width (A), residual alveolar bone height (B), sinus lift height (C), sinus lift width (D), and sinus lift depth (E). Manual augmentation volume was calculated using a geometric ellipsoid approximation formula derived from standardized linear measurements. AI-assisted volumetric estimation was performed using the volumetric analysis tool integrated within Planmeca Romexis 6.3 software. Two calibrated periodontists repeated both manual and AI-assisted measurements twice with a two-week interval. Reliability was assessed using intraclass correlation coefficients (ICC), while agreement between methods was evaluated using ICC and Bland–Altman analysis. Results: The mean manually calculated planned augmentation volume per implant site was 0.47 ± 0.11 cm3, whereas the mean AI-assisted planned augmentation volume was 0.52 ± 0.10 cm3. AI-assisted measurements were significantly greater than manual measurements (p < 0.001). Manual measurements demonstrated moderate intra- and inter-examiner reliability (ICC = 0.722, 0.701, and 0.649), whereas AI-assisted measurements demonstrated excellent reliability (ICC = 0.917, 0.924, and 0.903). Agreement between AI-assisted and manual volumetric estimation was good (ICC = 0.847). Bland–Altman analysis demonstrated a mean bias of 0.061 cm3 with limits of agreement ranging from 0.028 to 0.094 cm3. No significant associations were observed between augmentation volume and age, sex, or number of missing teeth after normalization per implant site (p > 0.05). Conclusions: AI-assisted volumetric estimation demonstrated excellent reproducibility and good agreement with manually calculated augmentation volumes while producing slightly higher volume estimates. AI-assisted volumetric estimation may serve as a reliable adjunctive tool for sinus augmentation planning by improving standardization and reducing operator-dependent variability.