Hady Saheb

Dr. Hady Saheb

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in Canadian Journal of Ophthalmology
Verified
Journal Article
Closed access
RCRonan Conlon
Ronan Conlon
HSHady Saheb
Hady Saheb
IAIqbal Ike K. Ahmed
Iqbal Ike K. Ahmed

1 September 2014 in Clinical Ophthalmology
Verified
Journal Article
Open access
HSHady Saheb
Hady Saheb
KLKim Le
Kim Le
Trabecular micro-bypass stents, commonly known as iStents, are micro-invasive glaucoma surgery (MIGS) devices used to treat open-angle glaucoma. Like other MIGS procedures that enhance trabecular outflow, the iStent lowers intraocular pressure (IOP) by creating a direct channel between the anterior chamber and Schlemm’s canal. iStents are typically implanted at the time of phacoemulsification for patients with open-angle glaucoma and visually significant cataracts. This review summarizes the published data regarding the efficacy, safety, and cost considerations of trabecular micro-bypass stents. Most studies found statistically significant reductions in mean IOP and ocular medication use after combined phacoemulsification with single or double iStent implantation. The devices were found to be very safe, with a safety profile similar to that of cataract surgery. Complications were infrequent, with the most common complications being temporary stent obstruction or malposition, which resolved with observation or secondary procedures. Future studies are needed to evaluate long-term outcomes, patient satisfaction, cost effectiveness, and expanded indications.

1 March 2021 in Ophthalmology Glaucoma
Verified
Journal Article
Closed access
ASAli Salimi
Ali Salimi
HNHarrish Nithianandan
Harrish Nithianandan
HFHuda Al Farsi
Huda Al Farsi
PHPaul Harasymowycz
Paul Harasymowycz
HSHady Saheb
Hady Saheb

20 June 2023 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
ASAli Salimi
Ali Salimi
HSHady Saheb
Hady Saheb

1 February 2019 in Ophthalmology
Verified
Journal Article
Closed access
CHCindy Hutnik
Cindy Hutnik
ACAndrew Crichton
Andrew Crichton
BFBryce Ford
Bryce Ford
MNMarcelo Nicolela
Marcelo Nicolela
LSLesya Shuba
Lesya Shuba
WHWilliam Hodge
William Hodge

1 February 2014 in Experimental Eye Research
Verified
Journal Article
Open access
Murray JohnstoneMurray Johnstone
Murray Johnstone
HSHady Saheb
Hady Saheb
IAIqbal Ike K. Ahmed
Iqbal Ike K. Ahmed
TSThomas W. Samuelson
Thomas W. Samuelson
ASAndrew T. Schieber
Andrew T. Schieber
CTCarol Toris
Carol Toris
This study evaluates the morphologic effect of the implantation of two different sizes of the Hydrus microstent on the outer wall of Schlemm's canal (SC) and collector channel (CC) ostia. Twelve human eyes were dissected at the equator removing the iris, lens, ciliary body and vitreous. The cornea was excised with a corneal trephine exposing a direct view of the angle while leaving the trabecular meshwork (TM) intact. The Hydrus delivery system was used to deliver microstents of 8 mm and 15 mm in length into SC. Following delivery, the tissues were immediately immersed in fixative. After tissue fixation, the microstents were gently lifted out of SC through the TM leaving a small slit opening in the TM. The slit opening was widened by gently dissecting the entire TM. Control eyes underwent dissection before fixation by gently removing the TM exposing the outer wall of SC. The tissues were prepared for scanning electron microscopy (SEM). The external wall of SC was imaged using SEM and were reviewed with particular attention focused on the distribution of irregular particulate matter (IPM), the shape of the CC ostia and the health of the SC endothelium. Three eyes received the 8 mm microstent, two the 15 mm microstent and 6 eyes served as controls. Five of the controls had reported histories of glaucoma while all other eyes were normal. All eyes showed evidence of removal of the trabecular meshwork revealing the external wall of SC. CCs were regularly visible in all eyes and were not obstructed, compressed or their margins disrupted. Nuclear profiles were oriented circumferentially in SC except at regions of CC ostia where they assumed a radial configuration oriented toward the lumen of the CC. The area of microstent contact with SC external wall was examined with SEM and a comparison made between the 8 and 15 mm microstent showing a smaller area of indentation with the 8 mm microstent. The indentations were generally free of particulate debris, were smooth and were devoid of nuclear profiles. In bridged areas adjacent to areas of microstent contact, CCs were identified, appearing patent and intact like those of the control eyes. The eyes receiving 8 mm and 15 mm Hydrus microstents both maintained CC ostia patency but a smaller area of external wall contact was evident from insertion of the 8 mm microstent.