Manuel Puga

Dr. Manuel Puga

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2021 in Neural Computing and Applications
Verified
Journal Article
Open access
PDF file
ANAlba Nogueira-Rodríguez
Alba Nogueira-Rodríguez
DCDomínguez- Carbajales
Domínguez- Carbajales
RURubén
Rubén
FCFernando Campos-Tato
Fernando Campos-Tato
JHJesús Herrero
Jesús Herrero
Gloria PenaGloria Pena
Gloria Pena
Colorectal cancer is a major health problem, where advances towards computer-aided diagnosis (CAD) systems to assist the endoscopist can be a promising path to improvement. Here, a deep learning model for real-time polyp detection based on a pre-trained YOLOv3 (You Only Look Once) architecture and complemented with a post-processing step based on an object-tracking algorithm to reduce false positives is reported. The base YOLOv3 network was fine-tuned using a dataset composed of 28,576 images labelled with locations of 941 polyps that will be made public soon. In a frame-based evaluation using isolated images containing polyps, a general F1 score of 0.88 was achieved (recall = 0.87, precision = 0.89), with lower predictive performance in flat polyps, but higher for sessile, and pedunculated morphologies, as well as with the usage of narrow band imaging, whereas polyp size < 5 mm does not seem to have significant impact. In a polyp-based evaluation using polyp and normal mucosa videos, with a positive criterion defined as the presence of at least one 50-frames-length (window size) segment with a ratio of 75% of frames with predicted bounding boxes (frames positivity), 72.61% of sensitivity (95% CI 68.99–75.95) and 83.04% of specificity (95% CI 76.70–87.92) were achieved (Youden = 0.55, diagnostic odds ratio (DOR) = 12.98). When the positive criterion is less stringent (window size = 25, frames positivity = 50%), sensitivity reaches around 90% (sensitivity = 89.91%, 95% CI 87.20–91.94; specificity = 54.97%, 95% CI 47.49–62.24; Youden = 0.45; DOR = 10.76). The object-tracking algorithm has demonstrated a significant improvement in specificity whereas maintaining sensitivity, as well as a marginal impact on computational performance. These results suggest that the model could be effectively integrated into a CAD system.

1 October 2015 in Gastroenterología y Hepatología
Verified
Journal Article
Closed access
JUJose Luis Ulla-Rocha
Jose Luis Ulla-Rocha
SLSusana Lopez-Piñeiro
Susana Lopez-Piñeiro
MPManuel Puga
Manuel Puga

1 January 2019 in Revista Española de Enfermedades Digestivas
Verified
Journal Article
Open access
MLMaria Curieses Luengo
Maria Curieses Luengo
CCClaudia F. Consiglieri
Claudia F. Consiglieri
MPManuel Puga
Manuel Puga
HBHospital Universitari de Bellvitge-IDIBELL
Hospital Universitari de Bellvitge-IDIBELL
The appearance of the lumen-apposing metal stent (LAMS) has meant an authentic revolution. To date, the results are promising but it is necessary to note the technical incidents and LAMS-related complications. an EUS-transmural guided drainage using a HotAXIOS was planned for a 36-year-old man with oral intolerance due to a voluminous walled-off necrosis. The distal flange was left in the collection, but a total distal malposition occurred during the proximal flange delivery, despite correct apposition with visualization of the black mark. A rescue technique was performed inserting a second LAMS over-the-guidewire salvaging the initial failed transmural drainage. This case is a reminder that in similar scenarios, extreme tension of the echoendoscope can cause a malfunction of the AXIOS stent delivery system, and lead to a total distal malposition. This "LAMS-in-LAMS" technique is feasible, effective, and a very helpful rescue technique in cases of dislodged LAMS.

13 February 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
PDPedro Davila-Piñón
Pedro Davila-Piñón
TPTeresa Pedrido
Teresa Pedrido
AMAstrid Irene Díez Martín
Astrid Irene Díez Martín
JHJesús Herrero
Jesús Herrero
MPManuel Puga
Manuel Puga
Joaquin CubiellaJoaquin Cubiella
Joaquin Cubiella
Background: PolyDeep is a computer-aided detection and characterization system that has demonstrated a high diagnostic yield for in vitro detection of colorectal polyps. Our objective is to compare the diagnostic performance of expert endoscopists and PolyDeep for colorectal polyp detection. Methods: PolyDeep Advance 1 (NCT05514301) is an unicentric diagnostic test study with a second observer design. Endoscopists performed colonoscopy blinded to PolyDeep’s detection results. The main endpoint was the sensitivity for colorectal polyp (adenoma, serrated or hyperplastic lesion) detection. The secondary endpoints were the diagnostic performance for diminutive lesions (≤5 mm), neoplasia (adenoma, serrated lesion) and adenoma detection. Results: We included 205 patients (55.1% male, 63.0 ± 6.2 years of age) referred to colonoscopy (positive faecal immunochemical occult blood test = 60.5%, surveillance colonoscopy = 39.5%). We excluded eight patients due to incomplete colonoscopy. Endoscopists detected 384 lesions, of which 39 were not detected by PolyDeep. In contrast, PolyDeep predicted 410 possible additional lesions, 26 of these predictions confirmed by endoscopists as lesions, resulting in a potential 6.8% detection increase with respect to the 384 lesions detected by the endoscopists. In total, 410 lesions were detected, 20 were not retrieved, five were colorectal adenocarcinoma, 343 were colorectal polyps (231 adenomas, 39 serrated and 73 hyperplastic polyps), 42 were normal mucosa and 289 were ≤5 mm. We did not find statistically significant differences between endoscopists and PolyDeep for colorectal polyp detection (Sensitivity = 94.2%, 91.5%, p = 0.2; Specificity = 9.5%, 14.3%, p = 0.7), diminutive lesions (Sensitivity = 92.3%, 89.5%, p = 0.4; Specificity = 9.8%, 14.6%, p = 0.7), neoplasia (Sensitivity = 95.2%, 92.9%, p = 0.3; Specificity = 9.6%, 13.9%, p = 0.4) and adenoma detection (Sensitivity = 94.4%, 92.6%, p = 0.5; Specificity = 7.2%, 11.8%, p = 0.2). Conclusions: Expert endoscopists and PolyDeep have similar diagnostic performance for colorectal polyp detection.

8 June 2023 in Gastroenterología y Hepatología
Verified
Journal Article
Closed access
CTCoral Tejido
Coral Tejido
MPManuel Puga
Manuel Puga
CRCristina Regueiro
Cristina Regueiro
MFMaría Francisco
María Francisco
LRLaura Rivas
Laura Rivas
ESEloy Sánchez
Eloy Sánchez

10 March 2026 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
ANAlba Nogueira-Rodríguez
Alba Nogueira-Rodríguez
RDRubén Domínguez-Carbajales
Rubén Domínguez-Carbajales
FCFernando Campos-Tato
Fernando Campos-Tato
JHJesús Herrero
Jesús Herrero
MPManuel Puga
Manuel Puga
MRMiguel Reboiro-Jato
Miguel Reboiro-Jato
Colorectal cancer is the third most common cancer worldwide and presents a high mortality rate. Colonoscopy is the gold standard for screening, as it can reduce its incidence and mortality. Deep Learning techniques have become state-of-the-art in lesion detection and classification, and several Deep-Learning-based Computer-Aided Diagnosis systems are already undergoing clinical evaluation or commercialization. However, the development of reliable models requires large, high-quality datasets, which are costly and time-consuming to create. Thus, the availability of public datasets is critical for the scientific community to develop artificial intelligent models. This work aims to contribute to the available resources by presenting PIBAdb, a new multimodal public cohort of colorectal videos and images. The PIBAdb cohort contains polyp data derived from routine colonoscopies conducted between January 2018 and May 2021 at Hospital Universitario de Ourense, under the PolyDeep project. Each polyp was resected, histologically analysed, morphologically classified, and annotated by expert clinicians with bounding boxes in images and temporal segments in videos. The main characteristics of PIBAdb were compared with another 25 public datasets. The utility of PIBAdb was evaluated in polyp detection and classification scenarios using Deep Learning models. PIBAdb includes detailed clinical and histological metadata from 1176 polyps, 31,946 manually annotated polyp images, 14,124 non-polyp images, nearly 7 h of annotated video segments showing polyps, and over 4 h of annotated video segments without polyps. It comprises both the raw database and several curated image datasets, each accompanied by metadata and documentation. PIBAdb is publicly available upon request for non-profit purposes. PIBAdb is one of the largest and most complete multimodal public datasets for colorectal polyp research. It is characterized by its rich per-polyp metadata (histology and PARIS/NICE classifications), inclusion of NBI and WL images, and non-polyp images at multiple levels of cleanness. While the image datasets included are practical for developing classification or detection models, the full database enables more complex video-based research and custom dataset creation using the PIBA management tool, supported by a queryable relational database. Its availability is expected to support the development of Deep Learning models and to foster future contributions from the research community.