Xiujie Wen

Xiujie Wen


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2026 in International Dental Journal
Verified
Journal Article
Open access
SLSen Liu
Sen Liu
YZYayue Zheng
Yayue Zheng
RSRui She
Rui She
LLLinyi Liu
Linyi Liu
FLFang Li
Fang Li
XWXiujie Wen
Xiujie Wen
In this finite element study, the biomechanical effects of force application at different lingual versus labial sites on a maxillary central incisor with alveolar bone loss and proclination were compared. Finite element models were constructed to simulate 4 levels of alveolar bone loss: none, 1/3, 1/2, and 2/3 of the root length. Labiolingual inclination was defined by the U1-SN angle (97°-115°). A combined force of 1.5 N retraction and 0.5 N intrusion was applied at 4 sites: the labial crown centre (La), the lingual fossa midpoint (Li(M)), the lingual fossa-cingulum transition (Li(T)), and the cingulum prominence (Li(P)). In models with 0-1/3 bone loss, labial forces produced predictable mesial crown displacement with increasing U1 SN angle, improving sagittal control. Lingual forces reduced distal displacement-most effectively at Li(M)-while Li(P) best controlled lingual inclination. Vertically, intrusion occurred under labial force with 1/3 loss, but extrusion under lingual force. Models with 1/2-2/3 bone loss showed complex horizontal movements, vertical extrusion, and reduced 3-dimensional control. Periodontal ligament (PDL) stress varied with force site, angle, and bone loss. Without loss, peak stress occurred near 100°; greater loss shifted this peak and increased stress. Sensitivity analysis showed that a 30% reduction in PDL modulus increased displacement by 43%, whereas a 30% increase reduced it by 23%. Alveolar bone loss is the dominant factor influencing tooth displacement patterns and results in greater than ±30% changes in the PDL modulus inclination. Increased bone loss exacerbates crown lingual tipping and extrusion. Labial force provides better control over lingual tipping than lingual force does. Among lingual sites, the cingulum minimizes these adverse movements. Sensitivity analysis confirmed that variations in the elastic modulus of the PDL led to changes in initial tooth displacement, whereas the tooth movement rate remained relatively stable.

19 May 2026 in Journal of International Medical Research
Verified
Journal Article
Open access
PYPing-Zhu Yang
Ping-Zhu Yang
XWXiujie Wen
Xiujie Wen
RLRui Liu
Rui Liu
During orthodontic treatment, ensuring the safety of anterior teeth with exposed roots is crucial. Our report describes the case of a 19-years-old female patient who was treated at a local clinic for severe bimaxillary protrusion. The clinic physician extracted the patient’s seven premolars and one mandibular lateral incisor, resulting in failure of the orthodontic treatment. After this failed treatment at the local clinic, the patient presented to our hospital for follow-up treatment (second treatment). When the patient was transferred to our hospital, she still exhibited a skeletal Class II relationship (A point-nasion-B point angle (ANB): 12.5°) profile, and her anterior teeth were severely upright, with an initial U1-NA of −1.5° (normal value: 22.8° ± 5.7°). This value changed after treatment to 14.32° (normal value 22.8° ± 5.7°). Cone beam computed tomography showed that the roots of the anterior teeth had penetrated the labial cortical bone, and it was challenging to ensure the safety of the second treatment. In our patient, the roots of the anterior teeth safely entered the center of the maxilla, with the U1-NA changing from −1.5° to 11° after treatment with our self-made four-curvature torquing auxiliary arch. Moreover, root length did not change, and root absorption did not occur.

23 March 2026 in Cellular Signalling
Verified
Journal Article
Closed access
JMJingwen Mao
Jingwen Mao
XPXiaoming Pu
Xiaoming Pu
LTLang Tian
Lang Tian
YCYingxin Chen
Yingxin Chen
YLYangjun Liu
Yangjun Liu
XWXiujie Wen
Xiujie Wen

6 July 2026 in Scientific Reports
Verified
Journal Article
Open access
YZYayue Zheng
Yayue Zheng
RZRuijing Zhang
Ruijing Zhang
FLFang Li
Fang Li
SLSen Liu
Sen Liu
YJYunyi Jin
Yunyi Jin
XWXiujie Wen
Xiujie Wen
The objectives of this study were to (1) evaluate the effect of different customized base designs on the shear bond strength (SBS) of metal orthodontic brackets fabricated by selective laser melting (SLM) and (2) assess their clinical feasibility. Seventy-five extracted human premolars were randomly divided into five groups (n = 15). Five types of bracket bases were designed: smooth base, pin-retention base, mesh base, hexagonal honeycomb base, and hollow honeycomb base. All brackets were fabricated using SLM technology with 316 L stainless steel. SBS was measured using a universal testing machine, and adhesive remnant index (ARI) scores were evaluated under magnification. Statistical analysis was performed using one-way analysis of variance (ANOVA) and Kruskal-Wallis tests. Significant differences in SBS were observed among the groups (P < 0.05). The hollow honeycomb group showed the highest bond strength, followed by the hexagonal honeycomb group. No significant differences in ARI scores were found among the groups (P > 0.05). SLM-fabricated customized orthodontic brackets demonstrated clinically acceptable bonding performance levels. The hollow honeycomb base design significantly improved mechanical retention and bond strength.