Plasmodium falciparummalaria is the most common infection in Yemen. The present study aims to investigate changes in hematological and hepatic function indices ofP. falciparuminfected individuals. This study included 67 suspectedfalciparummalarial patients attended in clinics and rural Abs Hospital (Tehama, Hajjah), Yemen, from October 2013 to April 2014. The diagnosis of malaria was confirmed by thick and thin film with Giemsa staining of malaria parasite. Hematological parameters and serum levels of aspartate transaminase (AST), alanine transaminase (ALT), alkaline phosphatase (ALP), and bilirubin (total and direct) as test indicators of liver function were studied. Patients with parasitaemia tended to have significantly lower hemoglobin, hematocrit, white blood cell count, lymphocytes, and platelets, compared with healthy normal subjects. Neutrophils levels were significantly higher in cases offalciparummalaria in comparison to healthy normal subjects. Serums AST, ALT, ALP, and bilirubin (total and direct) infalciparummalaria patients were significantly higher () than those offalciparummalaria of free individuals. Hematological and liver dysfunctions measured parameters were seen associated with moderate and severe parasitaemia infection. This study concludes that hematological and hepatic dysfunction parameters could be indicator of malaria in endemic regions.
8 May 2017 in Journal of Microbiology & Experimentation
Clinical data indicate that oxidative stress and activities may play important roles in Plasmodium falciparum. The aim of this study was to assess the erythrocyte antioxidants and evaluate enzyme activities as marker for Plasmodium falciparum malaria patients. The diagnosis of malaria was confirmed by thick and thin film with Giemsa staining of malaria parasite. Ninety consenting individuals, sixty infected patients and thirty uninfected subjects comprising both sexes were randomly selected and age range between 18 to 48 years. The levels of Erythrocytic superoxide dismutase eSOD, serum ceruloplasmin (CP), vitamin C, alkaline phosphatase (ALP) and lactate dehydrogenase (LDH) were determined. Low levels of essential antioxidants such as eSOD and vitamin C in the patients have been found to be associated with an increased risk of Plasmodium falciparum malaria. Low levels of antioxidants observed in the falciparum malaria patients may be due to their increased utilization to free radical scavenger. High level of CP observed in the Plasmodium falciparum malaria patients may be of powerful potency against oxidative stress. Furthermore, lowered levels of antioxidants especially of vitamin C in malaria infection suggest that antioxidant may play a major role in the treatment of malaria infection. It was detected that serum levels of ALP and LDH were significantly higher in Plasmodium falciparum malaria patients group, compared with the healthy group. Higher levels of LDH and ALP in the Plasmodium falciparum malaria patients may be used in the diagnosis and treatment and monitoring of patients with malaria. Results also suggest that the rise in LDH activity may be as a result of the cellular anoxia of liver rather than other tissues in malaria patients.
Furfural is one of the main pollutant materials in petroleum refinery wastewater. This work used an ozonized bubble column reactor to remove furfural from wastewater. The reactor applied two shapes of packing materials and two dosages of CuO nanocatalyst (0.05 and 0.1 ppm) to enhance the degradation process. The results indicated that adding 0.1 ppm of nanocatalyst provided an efficient rate of furfural degradation compared to that of 0.05 ppm. Also, the packing materials enhanced the furfural degradation significantly. As a result, the contact area between the gas and liquid phases increased, and a high furfural removal efficiency was achieved. It was found that the CuO nanocatalyst generated more (OH•) radicals. At a treatment time of 120 min and an ozone flow of 40 L/h, the furfural degradation recorded values of 80.66 and 78.6% at 10 and 20 ppm of initial concentration, respectively. At 60 ppm, the degradation efficiency did not exceed 74.16%. Furthermore, the kinetic study indicated that the first-order mechanism is more favorable than the second-order mechanism, representing the furfural degradation with a correlation factor of 0.9837. Finally, the furfural reaction can be achieved successfully in a shorter time and at low cost.
1 January 2021 in Chemical Industry and Chemical Engineering Quarterly
Phenol and Phenolic compounds are omnipresent organics contaminants which are sent out to inbred water bodies and wastewater systems produced from the industrials processes, and it takes individual attention due to its extraordinary features such as high toxicity, carcinogenic characteristics, and ability to a gathering which affects the health of humans and the milieu. In this practical study, the integrated system of a pulsation bubble column with an inverse fluidization air loop reactor was tested to remove phenol. The test platform was made and operated with a bubble column containing at its upper end an electrical solenoid valve engaged via at least two timers, and connected to the air loop reactor consisting of an outer rectangular tube and an internal draft tube by One-way valve, where the granular activated carbon is put as an adsorbent material in the annulus region between the inner and outer tube. The effect of various parameters [molar ratio of Phenol to H2O2 (1/10, 1/15 and 1/20), airflow rate (5-20liter/min), remediation time (5-60min), initial phenol concentration (10-150) mg L-1] has been studied. Removing 90% of the contaminated phenol as a result of this study may represent a partial solution to the ecological problem.
1 November 2020 in International Journal of Engineering
In this study, the feasibility of using the developed design for the removal of organic pollutants from wastewater was examined. The design includes the integration of the work of both pulsation bubble column (PBC) and the inverse fluidization airlift loop reactor (IFALR). The experimental podium was fabricated and installed which that consists of a bubble column with a diameter of 5 cm and a height of 210 cm, contains at the top a solenoid valve which is electrically turned via at least two timers, and its connection with the loop reactor by a one-way valve. The loop reactor consists of an outer rectangular tube with dimensions (29 cm long x 15.5 cm wide x 150 cm high) and an internal draft tube with 9 cm diameter and 120 cm long as granular activated carbon is put as an adsorbent in the annulus region between the inner and outer tube. Experiments were conducted using one of the organic pollutants namely chloroform, with a work scenario that includes changing both the airflow rate (2-20) liters/minute, the total survival time of the treatment (5-60) minutes, the molar ratio of the chloroform pollutant to the oxidizing agent of hydrogen peroxide (1/10 - 1/20). The results showed removal efficiency near to 89%, and it gives an indication of the success of the proposed design, with the possibility of recycling the treated water and releasing it to the environment due to the low risk of the organic pollutant in it.
1 July 2019 in Environmental Health Engineering and Management
Background: Several important designs have been applied to remove toxic and hazardous organic substances like phenol and phenol compounds from wastewater, but there is a need to seek an alternative design to effectively remove organic pollutants from water to less hazardous compounds and a costeffective system. Methods: A modified internal loop airlift reactor was designed to remove the organic pollutants in synthetic wastewater using an efficient and cost-effective treatment technique by means of a synergistic effect of combination oxidation, stripping, and adsorption. The influence of the current style was experimentally examined in the treatment of synthetic phenol contaminated wastewater. The practical device was tested under different airflow rates range (2-15 L/min) through gross difference retention period (5-60 minutes) at a various molar ratio of phenol to hydrogen peroxide ranging from 1:10 to 1:20. Results: It was revealed that the preferred molar ratio of phenol to hydrogen peroxide equals to 1:20. Moreover, the airflow rate is 15 L/min with longer retention period of 60 minutes, indicating the maximum removal efficiency (89%) of phenol from the synthetic wastewater. Conclusion: Successful removal of phenol from water by the removal efficiency of 89% boosts the success of the executed design as well as the scenario of conducting the synergistic processes (stripping, oxidation and adsorption) in one device and also increases the chances of solving environmental problems via treating wastewater before recycling and releasing it into natural water sources.