Zhibiao Cheng

Dr. Zhibiao Cheng

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2025 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
ZCZhibiao Cheng
Zhibiao Cheng
PCPing Chen
Ping Chen
JYJianhua Yan
Jianhua Yan
Single photon emission computed tomography (SPECT), a technique capable of capturing functional and molecular information, has been widely adopted in theranostics applications across various fields, including cardiology, neurology, and oncology. The spatial resolution of SPECT imaging is relatively poor, which poses a significant limitation, especially the visualization of small lesions. The main factors affecting the limited spatial resolution of SPECT include projection sampling techniques, hardware and software. Both hardware and software innovations have contributed substantially to improved SPECT imaging quality. The present review provides an overview of state-of-the-art methods for improving spatial resolution in clinical and pre-clinical SPECT systems. It delves into advancements in detector design and modifications, projection sampling techniques, traditional reconstruction algorithm development and optimization, and the emerging role of deep learning. Hardware enhancements can result in SPECT systems that are both lighter and more compact, while also improving spatial resolution. Software innovations can mitigate the costs of hardware modifications. This survey offers a thorough overview of the rapid advancements in resolution enhancement techniques within the field of SPECT, with the objective of identifying the most recent trends. This is anticipated to facilitate further optimization and improvement of clinical systems, enabling the visualization of small lesions in the early stages of tumor detection, thereby enhancing accurate localization and facilitating both diagnostic imaging and radionuclide therapy, ultimately benefiting both clinicians and patients.

7 September 2020 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
YLYueer Li
Yueer Li
ZCZhibiao Cheng
Zhibiao Cheng
CYChen Yang
Chen Yang
MWMengfu Wei
Mengfu Wei
JWJunhai Wen
Junhai Wen
Current methods for the imaging of radioactive sources ignore the surrounding scene information. Reconstruction results do not have real scale meaning, creating difficulties for further disposal and management of nuclear waste. In addition, the traditional reconstruction method requires fixed hardware to directly measure the reconstruction parameters. In recent years, the combination of Computer Vision and traditional radiation imaging has been greatly performed. The binocular camera is a small, light-insusceptible visual instrument, suitable for integration with other instruments. In this paper, we present a method based on binocular vision technology to radioactive source image reconstruction. The binocular camera provides the assisting information about the surrounding scene and replaces the fixed hardware to indirectly achieve the measurement target of reconstruction parameters, which includes an azimuth angle and a distance. In addition, we designed a simple algorithm based on the Hough Transform and the regular shape of the waste drum to improve the spatial resolution for a good visualization. The experimental rendering results with different transparency degrees provide a good sense of spatial scale.

5 February 2022 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
ZCZhibiao Cheng
Zhibiao Cheng
LXLulu Xie
Lulu Xie
CFCuixia Feng
Cuixia Feng
JWJunhai Wen
Junhai Wen

12 February 2026 in Tomography
Verified
Journal Article
Open access
PDF file
ZCZhibiao Cheng
Zhibiao Cheng
JZJun Zhang
Jun Zhang
PCPing Chen
Ping Chen
JWJunhai Wen
Junhai Wen
Objectives: Due to collimator limitations, Single-Photon Emission Computed Tomography (SPECT) suffers from relatively low spatial resolution, which hampers the detection of small lesions. This study proposes a super-resolution (SR) reconstruction algorithm for a parallel-beam, low-resolution (LR) multi-detector SPECT system and employs a neural network to estimate and correct for geometric errors in the LR detectors. Methods: A parallel-beam LR multi-detector SPECT system is presented, in which the detectors perform relative sub-pixel shifts. At each sampling angle, an SR reconstruction algorithm synthesizes high-resolution (HR) SPECT images from LR projections acquired by four offset LR detectors. To correct for geometric errors among these detectors, a randomly distributed gamma point source was designed to generate training data. A neural network was then employed to estimate the geometric errors, thereby refining the SR reconstruction. Results: Numerical simulation demonstrated that the proposed neural network could accurately identify the displacement-based geometric errors of the LR detectors. Utilizing these estimated parameters to correct the SR reconstruction process yielded results comparable to those obtained from direct reconstruction of HR projections, achieving a two-fold resolution improvement. Conclusions: Preliminary proof-of-principle for SR reconstruction in a parallel-beam LR multi-detector SPECT system was established. Further validation of the hardware performance is warranted.

8 January 2021
Verified
Conference Paper
Open access
MLMiaomiao Lu
Miaomiao Lu
JZJun Zhang
Jun Zhang
ZCZhibiao Cheng
Zhibiao Cheng
JWJunhai Wen
Junhai Wen
The registration of two-dimensional MV electronic portal imaging device (EPID) images and digital reconstruction radiograph (DRR) images has been widely used for the setup error correction of radiotherapy, the approaches estimate the 3D transformation is not very accurate. The purpose of this paper is to verify the feasibility of a new setup error estimation method that registers 3D planning CT image and 3D image that is reconstructed based on EPID. EPID images were acquired and used to reconstruct the MVCT by Algebraic Reconstruction Technique (ART) algorithm. The reconstructed image and the planning CT were registered by maximizing the mutual information (MI) between two 3D images. The registration error is less than 3mm, which is suitable for clinical implementation. The study demonstrated that the 3D/3D registration method proposed for the setup error correction of radiotherapy is feasible.