Qiang Liang

Dr. Qiang Liang


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2025 in Fire
Verified
Journal Article
Open access
PDF file
JMJianan Men
Jianan Men
QLQiang Liang
Qiang Liang
HXHui Xu
Hui Xu
ZLZhenyu Liu
Zhenyu Liu
JLJielong Lv
Jielong Lv
XWXiaopo WANG
Xiaopo WANG
To investigate the performance patterns of high-pressure water mist sprinklers with different flow coefficients in smoke containment and thermal insulation during fire suppression, this study conducted droplet size experiments and small-scale fire tests at 8 MPa pressure using six sprinkler types with flow coefficients (K) of 0.5, 0.7, 1.0, 1.2, 1.5, and 2.0. These findings were systematically analyzed in conjunction with FDS numerical simulations. Droplet size results indicate optimal atomization for K = 1.0, 1.2, and 1.5 sprinklers, producing fine droplets with concentrated distribution. Small-scale experiments and simulations further compared their smoke suppression and heat insulation performance. Findings show K = 1.5 delivers superior smoke suppression and cooling effects, reducing protected area temperatures by 20~45 °C compared to other conditions while minimizing smoke spread. Although visibility was slightly lower than at K = 1.2 due to droplet size and particle count, the overall performance was superior. This study conclusively identified K = 1.5 as the optimal flow parameter, providing experimental evidence and theoretical support for the engineering application of high-pressure water mist sprinklers.

25 December 2025 in Fire
Verified
Journal Article
Open access
PDF file
HXHui Xu
Hui Xu
JMJianan Men
Jianan Men
TZTianze Zhang
Tianze Zhang
ZLZhen Liu
Zhen Liu
QLQiang Liang
Qiang Liang
XWXiaopo WANG
Xiaopo WANG
Transitional attack represents a pivotal tactic in modern firefighting, whose efficacy is profoundly contingent upon the impact characteristics of water streams and their subsequent distribution patterns. This study integrates computational fluid dynamics (CFD) simulations with experimental validation to develop a momentum decomposition model for jet impingement on a ceiling. The model analyzes the dominant mechanisms of tangential spread and normal rebound on water distribution and optimizes water application strategies. Theoretical analysis reveals that upon ceiling impact, the normal velocity component of the stream undergoes rapid attenuation, causing the flow to be predominantly governed by tangential diffusion. This phenomenon results in an asymmetrically elliptical ground distribution, characterized by a significant concentration of water volume at the terminus of the diffusion path, while wall boundaries induce further water accumulation. A comparative analysis of the stream impact process and water distribution demonstrates a high degree of concordance between experimental and simulation results, thereby substantiating the reliability of the proposed model. Numerical simulations demonstrate that an increased jet angle markedly improves both coverage area and flux density. Higher water pressure enhances jet kinetic energy, leading to improved distribution uniformity. Appropriately extending the horizontal projection distance of the water jet further contributes to broadening the effective coverage. The parametric combination of a 49° jet angle, water pressure of 0.2–0.25 MPa, and a relative horizontal distance of 1.5–2.0 m is identified as optimal for overall performance. This research provides a scientific foundation and practical operational guidelines for enhancing the efficiency and safety of the transitional attack methodology.