Mahfuzur Rahman

Dr. Mahfuzur Rahman


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2025 in Electronics
Verified
Journal Article
Open access
PDF file
Mahfuzur RahmanMahfuzur Rahman
Mahfuzur Rahman
BMBashir Morshed
Bashir Morshed
The electrocardiogram (ECG) is one of the vital physiological signals for human health. Lightweight neural network (NN) models integrated into a low-resource wearable device can benefit the user with a low-power, real-time edge computing system for continuous and daily monitoring. This work introduces a novel edge-computing wearable device for real-time beat-by-beat ECG arrhythmia classification. The proposed wearable integrates the light AI model into a 32-bit ARM® Cortex™-based custom printed circuit board (PCB). The work analyzes the performance of artificial neural network (ANN), convolutional neural network (CNN), and long short-term memory (LSTM) models for real-time wearable implementation. The wearable is capable of real-time QRS detection and feature extraction from raw ECG data. The QRS detection algorithm offers high reliability with a 99.5% F1 score and R-peak position error (RPE) of 6.3 ms for R-peak-to-R-peak intervals. The proposed method implements a combination of top time series, spectral, and signal-specific features for model development. Lightweight, pretrained models are deployed on the custom wearable and evaluated in real time using mock data from the MIT-BIH dataset. We propose an LSTM model that provides efficient performance over accuracy, inference latency, and memory consumption. The proposed model offers 98.1% accuracy, with 98.2% sensitivity and 99.5% specificity while testing in real time on the wearable. Real-time inferencing takes 20 ms, and the device consumes as low as 5.9 mA of power. The proposed method achieves efficient performance in real-time testing, which indicates the wearable can be effectively used for real-time continuous arrhythmia detection.


14 April 2023
Verified
Conference Paper
Closed access
Mahfuzur RahmanMahfuzur Rahman
Mahfuzur Rahman
RHRobert Hewitt
Robert Hewitt
BMBashir I. Morshed
Bashir I. Morshed
An embedded device is developed to acquire an electrocardiogram (ECG) signal by using only a single lead. The device is capable to capture the ECG signal of a human from the wrist or heart region and transmit data through Bluetooth low energy (BLE). The device includes a custom printed circuit board (PCB) for ECG acquisition. The custom PCB implements the AD 8232 chip for ECG calculation. The PCB is embedded with a commercial nRF52840 development board. Analog data from custom PCB is converted to the digital domain by using a 10-bit analog to digital converter (ADC) and transmitted through Bluetooth 5.3 both supplied by the development board. nRF52840 is 32 bit ARM ® Cortex™ processing unit. The BLE data is transmitted by a baud rate of 115.2 kbps. The PCB is 2-layer (32 mm X 50 mm X 4 mm). The device is powered by a 350 mA-hr LiPo battery and consumes approximately 0.58 mA of current. With this current consumption, the battery would last around 603 hours. Finally, all parts are packaged in a box to make it compact and functional for body-worn uses. The device is a low-cost, low-weight design suitable for mobile health (mHealth) applications.

14 May 2021
Verified
Conference Paper
Closed access
Mahfuzur RahmanMahfuzur Rahman
Mahfuzur Rahman
BMBashir I. Morshed
Bashir I. Morshed
Respiration rate is one of the important measures of any physiological changes in human body. In this paper, an inertial measurement unit (IMU) is used to detect the chest movement and estimate the respiration rate from the real-time signal. A commercial inertial motion sensor chip used in this study that produces linear motion vector as streaming data. The signal from the motion sensor was sampled at 10 Hz. Signal processing was applied to denoise respiration signals from the values of linear motion vectors. Then, an algorithm of calculating respiration rate, was used to estimate breath per minute (BPM). The results were compared with a commercial respiration monitor belt logger sensor as the ground truth. The IMU sensor was tested at 5 different BPMs (12, 15, 20, 24, and 30) to validate the data from the IMU sensor and from the commercial respiration belt using a protocol where different BPM was maintained. The results show high accuracy of the proposed system which is simpler to use, cheaper to protype, and can be integrated with a wearable device and a custom smartphone app using edge computing technique.

1 December 2021
Verified
Conference Paper
Closed access
Mahfuzur RahmanMahfuzur Rahman
Mahfuzur Rahman
BMBashir I. Morshed
Bashir I. Morshed
Respiratory behavior is one of the important parameters that indicate any physiological changes in human body. However, using a respiration sensor device for continuous monitoring is inconvenient and expensive. In this paper, an approach to acquire the respiration signal from the wrist electrocardiogram (ECG) is proposed. An analog front end (AFE) sampled at 100 Hz is used to collect ECG signals from the wrist to compute and verify the corresponding heart rate (HR) with a commercial ECG device. Signal processing mechanisms are applied on the raw data to denoise the ECG signal. The captured ECG signal is further processed to extract a breathing pattern to calculate a respiration rate (RR) in breath per minute (BPM). The extracted BPMs are compared with a commercial respiration monitor to validate the data by following a protocol at 5 different BPMs (12, 15, 20, 24 and 30). For each BPM, commercial respiration monitor is validated at first. Then, data are taken simultaneously wearing wrist electrodes and commercial respiratory device to validate the performance of our proposed method at different BPMs. The results indicate high accuracy of the proposed system which is low-cost, simpler to implement, can be integrated with a wearable device and remove the demand of any dedicated sensor for RR measurements.

31 October 2025 in Electronics
Verified
Journal Article
Open access
PDF file
Mahfuzur RahmanMahfuzur Rahman
Mahfuzur Rahman
BMBashir Morshed
Bashir Morshed
Monitoring electrocardiogram (ECG) and respiration continuously and non-invasively is essential for managing cardiopulmonary health. An effective wearable device can be used to regularly monitor key vitals, reducing the need for clinical visits. In this work, we propose a custom device for real-time continuous ECG by inkjet printed (IJP) dry electrodes and respiration monitoring by using a novel single 6-axis inertial measurement unit (IMU). The proposed system can extract the heart rate (HR) and respiration rate (RR) during static and dynamic postures. The respiration process implements a quaternion-based update and multiple filtering stages to estimate the signal. The custom device uses Bluetooth protocol to send the raw and processed data to a mobile application. The RR is investigated in stationary, i.e., sitting and standing, and dynamic, i.e., walking, running, and cycling, postures. The proposed device is evaluated with commercial Go Direct® respiration belt from Vernier® for RR and offers an overall accuracy of 99.3% and 98.6% for static and dynamic conditions, respectively. The wearable also offers 98.9% and 97.9% accuracy for HR measurements, respectively, in static and active postures when compared with the Kardia® device. Furthermore, the device is assessed in an ambulatory monitoring setup in both indoor and outdoor environments. The low-power wearable consumes an average of only 7.4 mA of current during data processing. The device performs effectively and efficiently in both stationary and active states, offering a low complexity, portable solution for real-time monitoring. The proposed system can benefit from the continuous monitoring and early detection of pulmonary and cardio-respiratory health issues.