Ruoyun Su

Dr. Ruoyun Su


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2025 in Electronics
Verified
Journal Article
Open access
PDF file
YSYang Song
Yang Song
LZLiman Zhang
Liman Zhang
RSRuoyun Su
Ruoyun Su
HZHaoyuan Zhan
Haoyuan Zhan
MDMingyuan Dai
Mingyuan Dai
MLManzhou Li
Manzhou Li
With the rapid advancement of virtual human technology and live-streaming e-commerce, virtual anchors have increasingly become key interactive entities in the digital economy. However, emerging issues such as fake reviews, abnormal tipping, and illegal transactions pose significant threats to platform financial security and user privacy. To address these challenges, a multimodal emotion–finance fusion security recognition framework (MSF-Net) is proposed, which integrates visual, audio, textual, and financial transaction signals to achieve cross-modal feature alignment and multi-signal risk modeling. The framework consists of three core modules: the multimodal alignment transformer (MAT), the fake review detection (FRD) module, and the multi-signal fusion decision module (MSFDM), enabling deep integration of semantic consistency modeling and emotion–behavior collaborative recognition. Experimental results demonstrate that MSF-Net achieves superior performance in virtual live-streaming financial security detection, reaching a precision of 0.932, a recall of 0.924, an F1-score of 0.928, an accuracy of 0.931, and an area under curve (AUC) of 0.956, while maintaining a real-time inference speed of 60.7 FPS, indicating outstanding precision and responsiveness. The ablation experiments further verify the necessity of each module, as the removal of any component leads to an F1-score decrease exceeding 4%, confirming the structural validity of the model’s hierarchical fusion design. In addition, a lightweight version of MSF-Net was developed through parameter distillation and quantization pruning techniques, achieving real-time deployment on mobile devices with an average latency of only 19.4 milliseconds while maintaining an F1-score of 0.923 and an AUC of 0.947. The results indicate that MSF-Net exhibits both innovation and practicality in multimodal deep fusion and security risk recognition, offering a scalable solution for intelligent risk control in data-driven artificial intelligence applications across financial and virtual interaction domains.

2 February 2026 in Electronics
Verified
Journal Article
Open access
PDF file
YGYunpeng Gong
Yunpeng Gong
PHPeng Hu
Peng Hu
ZZZihan Zhang
Zihan Zhang
PLPengyu Liu
Pengyu Liu
ZLZhengyang Li
Zhengyang Li
MLManzhou Li
Manzhou Li
Anomalous transaction behaviors in cryptocurrency markets exhibit high concealment, substantial diversity, and strong cross-modal coupling, making traditional rule-based or single-feature analytical methods insufficient for reliable detection in real-world environments. To address the research focus, a data-centric multimodal anomaly detection framework integrating generative augmentation, latent distribution modeling, and dual-branch real-time detection is proposed. The method employs a generative adversarial network with feature-consistency constraints to mitigate the scarcity of fraudulent samples, and adopts a multi-domain variational modeling strategy to learn the latent distribution of normal behaviors, enabling stable anomaly scoring. By combining the long-range temporal modeling capability of Transformer architectures with the sensitivity of online clustering to local structural deviations, the system dynamically integrates global and local information through an adaptive risk fusion mechanism, thereby enhancing robustness and real-time detection capability. Experimental results demonstrate that the generative augmentation module yields substantial improvements, increasing the recall from 0.421 to 0.671 and the F1-score to 0.692. In anomaly distribution modeling, the multi-domain VAE achieves an area under the curve (AUC) of 0.854 and an F1-score of 0.660, significantly outperforming traditional One-Class SVM and autoencoder baselines. Multimodal fusion experiments further verify the complementarity of the dual-branch detection structure, with the adaptive fusion model achieving an AUC of 0.884, an F1-score of 0.713, and reducing the false positive rate to 0.087. Ablation studies show that the complete model surpasses any individual module in terms of precision, recall, and F1-score, confirming the synergistic benefits of its integrated components. Overall, the proposed framework achieves high accuracy and high recall in data-scarce, structurally complex, and latency-sensitive cryptocurrency scenarios, providing a scalable and efficient solution for deploying data-centric artificial intelligence in financial security applications.

14 October 2025 in Electronics
Verified
Journal Article
Open access
PDF file
DXDonglei Xu
Donglei Xu
XHXinyi He
Xinyi He
RSRuoyun Su
Ruoyun Su
YZYinuo Zhang
Yinuo Zhang
MLManzhou Li
Manzhou Li
YZYan Zhan
Yan Zhan
We propose a local–global attention fusion network for benign–malignant discrimination of ovarian tumors in color Doppler ultrasound (CDFI). The framework integrates three complementary modules: a local enhancement module (LEM) to capture fine-grained texture and boundary cues, a Global Attention Module (GAM) to model long-range dependencies with flow-aware priors, and a Fusion Discriminator (FD) to align and adaptively reweight heterogeneous evidence for robust decision-making. The method was evaluated on a multi-center clinical dataset comprising 820 patient cases (482 benign and 338 malignant), ensuring a realistic and moderately imbalanced distribution. Compared with classical baselines including ResNet-50, DenseNet-121, ViT, Hybrid CNN–Transformer, U-Net, and SegNet, our approach achieved an accuracy of 0.923, sensitivity of 0.911, specificity of 0.934, AUC of 0.962, and F1-score of 0.918, yielding improvements of about three percentage points in the AUC and F1-score over the strongest baseline. Ablation experiments confirmed the necessity of each module, with the performance degrading notably when the GAM or the LEM was removed, while the complete design provided the best results, highlighting the benefit of local–global synergy. Five-fold cross-validation further demonstrated stable generalization (accuracy: 0.922; AUC: 0.961). These findings indicate that the proposed system offers accurate and robust assistance for preoperative triage, surgical decision support, and follow-up management of ovarian tumors.