Pulmonary dead space (VD) is an index of ventilation inhomogeneity and one of the determinants of the magnitude of tidal volume to maintain optimal blood gases. To identify the determinants of VD in ventilated newborns and to investigate differences in VD between prematurely born and term infants and those prematurely born infants who did or did not develop bronchopulmonary dysplasia (BPD). Sixty-one mechanically ventilated infants (15 term, 46 preterm) were studied at a median age of 8 (IQR 2-31) days; 32 of the preterm infants developed BPD. VD was determined from the difference between arterial and end tidal carbon dioxide (CO2) using a low dead space CO2 detector using the Bohr/Enghoff equation and was related to body weight (VD/kg) at the time of study. The time to peak tidal expiratory flow/expiratory time (TPTEF/TE) was measured during spontaneous breathing using a fixed orifice pneumotachograph. VD/kg was related to gestational age (r=-0.285, p=0.001), birth weight (r=-0.356, p<0.001), weight (r=-0.316, p<0.001) and postmenstrual age (r=-0.205, p=0.020) at measurement, days of ventilation (r=0.322, p<0.001) and TPTEF/TE (r=-0.397, p=0.003). The median VD/kg was higher in prematurely born infants [2.3 (IQR: 1.7-3.0) ml/kg] compared to term infants [1.5 (1.3-2.1) ml/kg, (p=0.003)] and in premature infants that developed BPD [2.6 (IQR 1.8-3.4) ml/kg] compared to those who did not [1.7 (IQR 1.1-1.9) ml/kg], (p<0.001). Numerous factors influence pulmonary dead space and thus an optimum tidal volume will differ according to the underlying demographics and respiratory status.
Background: Many preterm infants require supplemental oxygen in the newborn period but experience frequent fluctuations of their oxygen saturation levels. Intermittent episodes of hypoxia or hyperoxia increase the risk of complications. Compliance with achievement of oxygen saturation targets is variable, and the need for frequent adjustments of the inspired oxygen concentration increases workload. Closed-loop automated oxygen control systems (CLAC) improve achievement of oxygen saturation targets and reduce both episodes of hypoxia and hyperoxia and the number of manual adjustments. This study investigates whether CLAC compared with manual oxygen control reduces the duration of mechanical ventilation in preterm infants born at less than 31 weeks of gestation. Methods: This randomised controlled trial performed at a single tertiary neonatal unit is recruiting 70 infants born at less than 31 weeks of gestational age and within 48 h of initiation of mechanical ventilation. Infants are randomised to CLAC or manual oxygen control from recruitment until successful extubation. The primary outcome is the duration of mechanical ventilation, and secondary outcomes are the percentage of time spent within target oxygen saturation ranges, the time spent in hypoxia or hyperoxia, the number of manual adjustments required, the number of days on oxygen, the incidence of bronchopulmonary dysplasia and the length and cost of neonatal unit stay. The study is performed following informed parental consent and was approved by the Yorkshire and the Humber-Sheffield Research Ethics Committee (protocol version 1.1, 13 July 2021). Discussion: This trial will investigate the effect of CLAC on the duration of mechanical ventilation, which is an important clinical outcome as prolonged mechanical ventilation is associated with important adverse outcomes, such as bronchopulmonary dysplasia. Trial registration: ClinicalTrials.Gov NCT05030337. Registered on 17 August 2021
Neonates, especially those born prematurely, have low antioxidant capacity and are highly exposed to oxidant stress during the perinatal period. Oxidant stress damage has been associated with several diseases of prematurity, including respiratory distress syndrome (RDS), bronchopulmonary dysplasia (BPD), and pulmonary hypertension. In addition, preterm infants are frequently exposed to hypoxia or hyperoxia, which further increases oxidant stress and morbidity. This narrative review describes the relationship between oxidant stress, hyperoxia/hypoxia, and neonatal respiratory disorders. Preterm infants with respiratory distress syndrome and BPD have higher levels of oxidative stress biomarkers in plasma and in tracheal aspirates and reduced activity of antioxidant enzymes. Early, prolonged, and frequent intermittent hypoxaemic episodes are related to BPD development. Exposure to hyperoxia is linked to longer duration of respiratory support and higher BPD rates. Preclinical data showed that intermittent hypoxia and hyperoxia are associated with pulmonary hypertension (PH) and that hyperoxia can negatively affect the response to pulmonary vasodilators. Antioxidant treatments are not routinely implemented into clinical care due to their modest effect on clinical outcomes, associated complications, and limited clinical data. Optimisation of oxygen delivery and monitoring with closed-loop automated oxygen control systems could potentially reduce oxidant stress in the neonatal environment.
10 November 2025 in Archives of Disease in Childhood - Fetal and Neonatal Edition
Objective: To compare the duration of mechanical ventilation between preterm infants receiving closed-loop automated oxygen control (CLAC) or manual oxygen control. Design: Randomised controlled trial. Setting: Tertiary neonatal unit in London, UK. Patients: Infants (n=69) with a median (IQR) gestational age of 27.0 (25.6–29.0) weeks studied at a corrected postmenstrual age of 27.6 (25.9–29.1) weeks. Interventions: Infants were randomised to CLAC or manual oxygen control within 48 hours of initiation of mechanical ventilation if less than 7 days of age until successful extubation. Main outcome measures: Duration of mechanical ventilation. Results: The CLAC infants (n=34) compared with those who received manual control had a shorter duration of mechanical ventilation (median (range): 11 (1–57) vs 40 (3–134) days, p=0.027), a shorter duration of supplemental oxygen (median (range): 33 (0–100) vs 47 (3–335) days, p=0.031), a lower incidence of bronchopulmonary dysplasia (BPD) at 36 weeks postmenstrual age (55% vs 83.9%, p=0.015) and fewer required home oxygen (26.5% vs 51.4%, p=0.016). In the CLAC infants, the time spent in the target oxygen range (91%–95%) was increased (p<0.001) and the times spent in hypoxaemia (peripheral oxygen saturation level (SpO 2 )95%) were reduced (p<0.001). Conclusions: Use of CLAC in preterm, ventilated infants was associated with improved achievement of oxygen saturation targets, shorter durations of mechanical ventilation and supplemental oxygen treatment and a lower incidence of BPD. These results need to be replicated in larger multicentre studies before any change in routine practice could be recommended. Trial registration number: NCT05030337 .
Aim: To compare the time spent above the target oxygen saturation range (SpO 2 > 96%) and the duration of supplemental oxygen between ventilated infants receiving closed‐loop automated oxygen control (CLAC) or manual oxygen control in late preterm and term ventilated infants. Methods: Infants were randomised to receive CLAC or manual oxygen control from recruitment and within 24 h of mechanical ventilation until successful extubation. Results: Forty infants with a median (IQR) gestational age of 37.4 (35.9–38.5) weeks were studied at a corrected postmenstrual age of 37.6 (36.0–38.7) weeks. In infants randomised to CLAC ( n = 18) the time spent above the target oxygen saturation range was reduced by 20% ( p < 0.001), and the time spent in the target range (92%–96%) was increased by 32% ( p < 0.001) and the time spent in hyperoxia was reduced ( p = 0.003). CLAC reduced the time spent in hypoxemia (SpO 2 < 85%) ( p = 0.017) and there were fewer manual adjustments to the inspired oxygen concentration (FiO 2 ) ( p < 0.001). There was no significant difference in the duration of supplemental oxygen ( p = 0.271). Conclusion: CLAC in ventilated infants born at or near term was associated with reduced time spent in hyperoxemia, more time spent in the target oxygen range, and fewer manual adjustments to the FiO 2 .