Electrochemical energy storage technology, primarily lithium-ion batteries, has been widely applied in large-scale energy storage systems. However, differences in assembly structures, manufacturing processes, and operating environments introduce parameter inconsistencies among cells within a pack, producing complex, high-volume datasets with redundant and fragmented charge–discharge records that hinder efficient and accurate system monitoring. To address this challenge, we propose a hybrid ASW-UKF-TRF framework for the classification and compression of battery data collected from energy storage power stations. First, an adaptive sliding-window Unscented Kalman Filter (ASW-UKF) performs online data cleaning, imputation, and smoothing to ensure temporal consistency and recover missing/corrupted samples. Second, a temporally aware TRF segments the time series and applies an importance-weighted, multi-level compression that formally prioritizes diagnostically relevant features while compressing low-information segments. The novelty of this work lies in combining deployment-oriented engineering robustness with methodological innovation: the ASW-UKF provides context-aware, online consistency restoration, while the TRF compression formalizes diagnostic value in its retention objective. This hybrid design preserves transient fault signatures that are frequently removed by conventional smoothing or generic compressors, while also bounding computational overhead to enable online deployment. Experiments on real operational station data demonstrate classification accuracy above 95% and an overall data volume reduction in more than 60%, indicating that the proposed pipeline achieves substantial gains in monitoring reliability and storage efficiency compared to standard denoising-plus-generic-compression baselines. The result is a practical, scalable workflow that bridges algorithmic advances and engineering requirements for large-scale battery energy storage monitoring.
In the context of large-scale renewable integration and increasing demand for power-system flexibility, energy-storage systems are indispensable components of modern grids, and their safe, reliable operation is a decisive factor in investment decisions. To mitigate lifecycle degradation and cost increases caused by frequent charge–discharge cycles, this study puts forward a two-layer energy storage capacity configuration optimization approach with explicit integration of cycle life restrictions. The upper-level model uses time-of-use pricing to economically dispatch storage, balancing power shortfalls while maximizing daily operational revenue. Based on the upper-level dispatch schedule, the lower-level model computes storage degradation and optimizes storage capacity as the decision variable to minimize degradation costs. Joint optimization of the two levels thus enhances overall storage operating efficiency. To overcome limitations of the conventional Whale Optimization Algorithm (WOA)—notably slow convergence, limited accuracy, and susceptibility to local optima—an Improved WOA (IWOA) is developed. IWOA integrates circular chaotic mapping for population initialization, a golden-sine search mechanism to improve the exploration–exploitation trade-off, and a Cauchy-mutation strategy to increase population diversity. Comparative tests against WOA, Gray Wolf Optimizer (GWO), and Particle Swarm Optimization (PSO) show IWOA’s superior convergence speed and solution quality. A case study using measured load data from an industrial park in Zhuzhou City validates that the proposed approach significantly improves economic returns and alleviates capacity degradation.