Hend Alshaya

Dr. Hend Alshaya

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
MAMuhammad John Abbas
Muhammad John Abbas
HAHend Alshaya
Hend Alshaya
WBWided Bouchelligua
Wided Bouchelligua
NHNehal Hassan
Nehal Hassan
Inzamam Mashood NasirInzamam Mashood Nasir
Inzamam Mashood Nasir
Purpose: Gastrointestinal (GI) illness demands precise and efficient diagnostics, yet conventional approaches (e.g., endoscopy and histopathology) are time-consuming and prone to reader variability. This work presents GID-Xpert, a deep learning framework designed to improve feature learning, accuracy, and interpretability for GI disease classification. Methods: GID-Xpert integrates a hierarchical, multi-stage attention-driven mixture of experts with dynamic routing. The architecture couples spatial–channel attention mechanisms with specialized expert blocks; a routing module adaptively selects expert paths to enhance representation quality and reduce redundancy. The model is trained and evaluated on three benchmark datasets—WCEBleedGen, GastroEndoNet, and the King Abdulaziz University Hospital Capsule (KAUHC) dataset. Comparative experiments against state-of-the-art baselines and ablation studies (removing attention, expert blocks, and routing) are conducted to quantify the contribution of each component. Results: GID-Xpert achieves superior performance with 100% accuracy on WCEBleedGen, 99.98% on KAUHC, and 75.32% on GastroEndoNet. Comparative evaluations show consistent improvements over contemporary models, while ablations confirm the additive benefits of spatial–channel attention, expert specialization, and dynamic routing. The design also yields reduced computational cost and improved explanation quality via attention-driven reasoning. Conclusion: By unifying attention, expert specialization, and dynamic routing, GID-Xpert delivers accurate, computationally efficient, and more interpretable GI disease classification. These findings support GID-Xpert as a credible diagnostic aid and a strong foundation for future extensions toward broader GI pathologies and clinical integration.

13 November 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
STSara Tehsin
Sara Tehsin
HAHend Alshaya
Hend Alshaya
WBWided Bouchelligua
Wided Bouchelligua
Inzamam Mashood NasirInzamam Mashood Nasir
Inzamam Mashood Nasir
Background and Objective: Accurate classification of standard fetal ultrasound planes is a critical step in prenatal diagnostics, enabling reliable biometric measurements and anomaly detection. Conventional deep learning approaches, particularly convolutional neural networks (CNNs) and transformers, often face challenges such as domain variability, noise artifacts, class imbalance, and poor calibration, which limit their clinical utility. This study proposes a hybrid state–space and vision transformer framework designed to address these limitations by integrating sequential dynamics and global contextual reasoning. Methods: The proposed framework comprises five stages: (i) preprocessing for ultrasound harmonization using intensity normalization, anisotropic diffusion filtering, and affine alignment; (ii) hybrid feature encoding with a state–space model (SSM) for sequential dependency modeling and a vision transformer (ViT) for global self-attention; (iii) multi-task learning (MTL) with anatomical regularization leveraging classification, segmentation, and biometric regression objectives; (iv) gated decision fusion for balancing local sequential and global contextual features; and (v) calibration strategies using temperature scaling and entropy regularization to ensure reliable confidence estimation. The framework was comprehensively evaluated on three publicly available datasets: FETAL_PLANES_DB, HC18, and a large-scale fetal head dataset. Results: The hybrid framework consistently outperformed baseline CNN, SSM-only, and ViT-only models across all tasks. On FETAL_PLANES_DB, it achieved an accuracy of 95.8%, a macro-F1 of 94.9%, and an ECE of 1.5%. On the Fetal Head dataset, the model achieved 94.1% accuracy and a macro-F1 score of 92.8%, along with superior calibration metrics. For HC18, it achieved a Dice score of 95.7%, an IoU of 91.7%, and a mean absolute error of 2.30 mm for head circumference estimation. Cross-dataset evaluations confirmed the model’s robustness and generalization capability. Ablation studies further demonstrated the critical role of SSM, ViT, fusion gating, and anatomical regularization in achieving optimal performance. Conclusions: By combining state–space dynamics and transformer-based global reasoning, the proposed framework delivers accurate, calibrated, and clinically meaningful predictions for fetal ultrasound plane classification and biometric estimation. The results highlight its potential for deployment in real-time prenatal screening and diagnostic systems.

1 February 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
Inzamam Mashood NasirInzamam Mashood Nasir
Inzamam Mashood Nasir
HAHend Alshaya
Hend Alshaya
STSara Tehsin
Sara Tehsin
WBWided Bouchelligua
Wided Bouchelligua
Background/Objectives: Accurate and reliable automated dermoscopic lesion classification remains challenging. This is due to pronounced dataset bias, limited expert-annotated data, and poor cross-dataset generalization of conventional supervised deep learning models. In clinical dermatology, these limitations restrict the deployment of data-driven diagnostic systems across diverse acquisition settings and patient populations. Methods: Motivated by these challenges, this study proposes a transformer-based, dermatology-specific foundation model. The model learns transferable visual representations from large collections of unlabeled dermoscopic images via self-supervised pretraining. It integrates large-scale dermatology-oriented self-supervised learning with a hierarchical vision transformer backbone. This enables effective capture of both fine-grained lesion textures and global morphological patterns. The evaluation is conducted across three publicly available dermoscopic datasets: ISIC 2018, HAM10000, and PH2. The study assesses in-dataset, cross-dataset, limited-label, ablation, and computational-efficiency settings. Results: The proposed approach achieves in-dataset classification accuracies of 94.87%, 97.32%, and 98.17% on ISIC 2018, HAM10000, and PH2, respectively. It outperforms strong transformer and hybrid baselines. Cross-dataset transfer experiments show consistent performance gains of 3.5–5.8% over supervised counterparts. This indicates improved robustness to domain shift. Furthermore, when fine-tuned with only 10% of the labeled training data, the model achieves performance comparable to fully supervised baselines. Conclusions: This highlights strong data efficiency. These results demonstrate that dermatology-specific foundation learning offers a principled and practical solution for robust dermoscopic lesion classification under realistic clinical constraints.

24 November 2025 in Biomedicines
Verified
Journal Article
Open access
PDF file
Inzamam Mashood NasirInzamam Mashood Nasir
Inzamam Mashood Nasir
HAHend Alshaya
Hend Alshaya
STSara Tehsin
Sara Tehsin
WBWided Bouchelligua
Wided Bouchelligua
Objectives: Correctly identifying Central Nervous System (CNS) tumors through MRI is complicated by utilization of divergent MRI acquisition protocols, unequal tumor morphology, and a difficulty in systematically combining imaging with clinical information. This study presents the Adaptive Vision–Language Transformer (AVLT), a multimodal diagnostic infrastructure designed to integrate multi-sequence MRI with clinical descriptions while improving robustness and interpretability to domain shifts. Methods: AVLT integrates the MRI sequence (T1, T1c, T2, FLAIR) and clinical note text in a joint process using normalized cross-attention to establish association of visual patch embeddings with clinical token representations. An Adaptive Normalization Module (ANM) functions to mitigate distribution shift across datasets by adapting the statistics of domain-specific features. Auxiliary semantic and alignment losses were incorporated to enhance stability of multimodal fusion. Results: On all datasets, AVLT provided superior classification accuracy relative to CNN-, transformer-, radiogenomic-, and multimodal fusion-based models. The AVLT model accuracy was 84.6% on BraTS (OS), 92.4% on TCGA-GBM/LGG, 89.5% on REMBRANDT, and 90.8% on GLASS. AvLT AUC values are at least above 90 for all domains. Conclusions: AVLT provides a reliable, generalizable, and clinically interpretable method for accurate diagnosis of CNS tumors.

21 January 2026 in Biomedicines
Verified
Journal Article
Open access
PDF file
WAWiem Abdelbaki
Wiem Abdelbaki
HAHend Alshaya
Hend Alshaya
Inzamam Mashood NasirInzamam Mashood Nasir
Inzamam Mashood Nasir
STSara Tehsin
Sara Tehsin
SSSalwa Said
Salwa Said
WBWided Bouchelligua
Wided Bouchelligua
Background: Diagnosing CNS tumors through MRI is limited by significant variability in scanner hardware, acquisition protocols, and intensity characteristics at clinical centers, resulting in substantial domain shifts that lead to diminished reliability for automated models. Methods: We present a Domain-Adaptive MRI Learning Model (DA-MLM) consisting of an adversarially aligned hybrid 3D CNN–transformer encoder with contrastive regularization and covariance-based feature harmonization. Varying sequence MRI inputs (T1, T1ce, T2, and FLAIR) were inputted to multi-scale convolutional layers followed by global self-attention to effectively capture localized tumor structure and long-range spatial context, with domain adaptation that harmonizes feature distribution across datasets. Results: On the BraTS 2020 dataset, we found DA-MLM achieved 94.8% accuracy, 93.6% macro-F1, and 96.2% AUC, improving upon previously established benchmarks by 2–4%. DA-MLM also attained Dice score segmentation of 93.1% (WT), 91.4% (TC), and 89.5% (ET), improving upon 2–3.5% for CNN and transformer methods. On the REMBRANDT dataset, DA-MLM achieved 92.3% accuracy with segmentation improvements of 3–7% over existing U-Net and expert annotations. Robustness testing indicated 40–60% less degradation under noise, contrast shift, and motion artifacts, and synthetic shifts in scanner location showed negligible performance impairment (<0.06). Cross-domain evaluation also demonstrated 5–11% less degradation than existing methods. Conclusions: In summary, DA-MLM demonstrates improved accuracy, segmentation fidelity, and robustness to perturbations, as well as strong cross-domain generalization indicating the suitability for deployment in multicenter MRI applications where variation in imaging performance is unavoidable.

25 March 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
WAWiem Abdelbaki
Wiem Abdelbaki
WBWided Bouchelligua
Wided Bouchelligua
Inzamam Mashood NasirInzamam Mashood Nasir
Inzamam Mashood Nasir
STSara Tehsin
Sara Tehsin
HAHend Alshaya
Hend Alshaya
To perform screening of the retina on a population scale, an automated procedure is required that incorporates accurate, reproducible, interpretable, and computationally costeffective models. Existing approaches using convolutional or transformer architectures typically do not adequately represent both fine-grained pathology and large-scale retinal context simultaneously, which could adversely affect their reliability if used for large-scale applications in clinical practice. In this paper, we propose a hierarchical transformer-based screening framework for retinal fundus images that incorporates patch-based tokenization, global transformer encoding, and hierarchical aggregation of contextual information. We also developed a lightweight prediction head that supports screening for both single and multiple diseases. The framework has been evaluated using standard screening metrics, robustness, and cross-dataset generalization analyses on two eye retinopathy image databases: EyePACS and RFMiD. With regard to screening for a binary outcome of diabetic retinopathy, our method provided an accuracy of 89.4% and an area under the receiver operating characteristic (AUROC) curve of 93.6% on EyePACS and attained an accuracy of 95.2% and a macro-averaged F1 score of 82.7% on RFMiD. Our hierarchical transformer achieved improved robustness to degraded images and increased generalizability across datasets compared with all current state-of-the-art models. The proposed hierarchical transformer demonstrates strong potential for large-scale retinal screening and provides a promising foundation for future clinically validated deployment.