Classical Molecular Dynamics simulations were used to investigate the interfacial adsorption of ethane on ultrathin molten polyethylene films. We investigated the interfacial adsorption of supercritical ethane on ultrathin molten polyethylene films at various temperatures (298.15 - 448.15 K) and pressures (0.28 - 13.17 MPa). Ethane was found to accumulate preferentially at the film's interfaces rather than dissolving into the film's core. The ultra-thin, metastable films, studied at their mechanical stability limit, are composed of two overlapping interfaces. The films show some fractions of interfacial chains transiently desorbing from the film surface and entering the gas phase, which facilitates the accumulation of ethane at the interfaces. At 373.15 K and pressures between 0.29 and 9.65 MPa, the combined film interfaces adsorb between 4.8 and 8.6 times more ethane than the amount solubilized in the central, bulk region of the film. Interfacial tension decreases exponentially with increasing gas pressure. Interfacial tension is primarily governed by inter-chain interactions at the interface. Minor contributions arise from the vibrational dynamics of polyethylene chain fractions that transiently desorb from the film surface. Furthermore, the solubility of ethane in the film's bulk region exhibits a temperature-dependent inversion: at 298.15 K, the ethane density in the film's center slightly exceeds that of the bulk gas, but this trend reverses at 373.15 K and becomes more pronounced as the temperature increases. This indicates a potential solubility transition temperature between 298.15 and 373.15 K.
Classical Molecular Dynamics simulations were used to investigate the interfacial adsorption of supercritical ethane on ultrathin molten polyethylene films at various temperatures (298.15–448.15 K) and pressures (0.28–13.17 MPa). Ethane was found to accumulate preferentially at the film’s interfaces rather than dissolving into the film’s core. The ultra-thin, metastable films, studied at their mechanical stability limit, are composed of two overlapping interfaces. The films show some fractions of interfacial chains transiently desorbing from the film surface and entering the gas phase, which facilitates the accumulation of ethane at the interfaces. At 373.15 K and pressures between 0.29 MPa and 9.65 MPa, the combined film interfaces adsorb between 4.8 and 8.6 times more ethane than the amount solubilized in the central, bulk region of the film. Interfacial tension of the film decreases exponentially with increasing gas pressure of ethane and is primarily governed by inter-chain interactions at the interface. Minor contributions arise from the vibrational dynamics of polyethylene chain fractions that transiently desorb from the film surface. Furthermore, the solubility of ethane in the film’s bulk region exhibits a temperature-dependent inversion: at 298.15 K, the ethane density in the film’s center slightly exceeds that of the bulk gas, but this trend reverses at 373.15 K and becomes more pronounced as the temperature increases. This indicates a potential solubility transition temperature between 298.15 K and 373.15 K.
1 October 2026 in REVISTA DE CIENCIAS TECNOLÓGICAS
Este estudio de caso reporta el desarrollo y la evaluación de un modelo integrado de gestión de residuos basado en la metodología 5S para una facultad de ciencias de la salud de una universidad pública del centro de México, donde coexisten flujos de residuos sólidos urbanos, de manejo especial y peligrosos biológico-infecciosos. La investigación siguió un diseño de caso único que comprendió diagnóstico de línea base, caracterización técnica de los residuos, diseño de un modelo operativo estructurado en torno a las cinco etapas 5S (Seiri, Seiton, Seiso, Seiketsu, Shitsuke), implementación piloto y evaluación. El diagnóstico estimó una generación aproximada de 2,200 kg de residuos al mes en condiciones de disposición mezclada y recuperación efectiva nula, mientras que la caracterización mostró que hasta el 79% del flujo tenía potencial de recuperación si se aplicaba una segregación adecuada. El modelo tradujo cada etapa 5S en acciones concretas de gestión de residuos, incluidas estaciones con código de color, rutas internas, criterios de almacenamiento temporal, señalización de peligro basada en el Sistema Globalmente Armonizado, contenedores diferenciados para residuos biológico-infecciosos y registros básicos. La evaluación se centró en el orden operativo, la efectividad de la segregación, la seguridad y la alineación regulatoria con las normas mexicanas (NOM-161-SEMARNAT-2011 y NOM-087-SEMARNAT-SSA1-2002). La intervención produjo una arquitectura operativa coherente que convierte el potencial de recuperación identificado en práctica rutinaria, al tiempo que redujo los riesgos de exposición y mejoró el cumplimiento normativo. La principal contribución es un marco replicable y de bajo costo a escala de facultad que conecta los objetivos de sostenibilidad del campus con las operaciones diarias, particularmente en entornos académicos del área de la salud de instituciones públicas con recursos limitados en América Latina.
Cada día utilizamos medicamentos, productos de higiene personal, cosméticos y detergentes sin pensar qué ocurre con ellos después de cumplir su función. Muchos de estos compuestos no desaparecen al irse por el drenaje, sino que llegan a ríos, lagos y acuíferos en concentraciones muy bajas, pero con efectos que pueden acumularse con el tiempo. A estos se les conoce como contaminantes emergentes: sustancias que no siempre están reguladas por la ley, pero que representan un riesgo potencial para el ambiente y la salud. En este artículo se explica qué son los contaminantes emergentes farmacéuticos, por qué su presencia en el agua es motivo de preocupación y qué acciones cotidianas pueden ayudar a reducir su impacto.