Jessica Tryner

Dr. Jessica Tryner

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Atmospheric Environment
Verified
Journal Article
Closed access
JTJessica Tryner
Jessica Tryner
CLChristian L'ORange
Christian L'ORange
JMJohn Mehaffy
John Mehaffy
DMDaniel Miller-Lionberg
Daniel Miller-Lionberg
JHJosephine C. Hofstetter
Josephine C. Hofstetter
JVJohn Volckens
John Volckens

1 December 2020 in Journal of Aerosol Science
Verified
Journal Article
Closed access
JTJessica Tryner
Jessica Tryner
JMJohn Mehaffy
John Mehaffy
DMDaniel Miller-Lionberg
Daniel Miller-Lionberg
JVJohn Volckens
John Volckens

27 May 2019 in Environmental Science & Technology
Verified
Journal Article
Closed access
KBKelsey R. Bilsback
Kelsey R. Bilsback
JDJordyn Dahlke
Jordyn Dahlke
KFKristen M. Fedak
Kristen M. Fedak
NGNicholas Good
Nicholas Good
AHArsineh Hecobian
Arsineh Hecobian
JVJohn Volckens
John Volckens

1 December 2014 in Energy for Sustainable Development
Verified
Journal Article
Closed access
JTJessica Tryner
Jessica Tryner
BWBryan D. Willson
Bryan D. Willson
AMAnthony J. Marchese
Anthony J. Marchese

5 December 2023 in Aerosol Science and Technology
Verified
Journal Article
Closed access
JOJames Ouimette
James Ouimette
WAW. Patrick Arnott
W. Patrick Arnott
PLPhilip Laven
Philip Laven
RWRichard Whitwell
Richard Whitwell
NRNagarajan Radhakrishnan
Nagarajan Radhakrishnan
JVJohn Volckens
John Volckens
Most evaluations of low-cost aerosol sensors have focused on their measurement bias compared to regulatory monitors. Few evaluations have applied fundamental principles of aerosol science to increase our understanding of how such sensors work and could be improved. We examined the Plantower PMS5003 sensor's internal geometry, laser properties, photodiode responses, microprocessor output, flow rates, and response to mono- and poly-disperse aerosols. We developed a physics-based model of particle light scattering within the sensor, which we used to predict counting and sizing efficiency for 0.30 to 10 μm particles. We found that the PMS5003 counts single particle scattering events, acting like an imperfect optical particle counter, rather than a nephelometer. As particle flow is not focused into the core of the laser beam, >99% of particles that flow through the PMS5003 miss the laser, and those that intercept the laser usually miss the focal point and are subsequently undersized, resulting in erroneous size distribution data. Our model predictions of PMS5003 response to varying particle diameters, aerosol compositions, and relative humidity were consistent with laboratory data. Computational fluid dynamics simulations of the PurpleAir monitor housing showed that for wind-speeds less than 3 m s-1, fine and coarse particles were representatively aspired to the PMS5003 inlet. Our measurements and models explain why the PurpleAir overstates regulatory PM2.5 in some locations but not others; why the PurpleAir PM10 is unresponsive to windblown dust; and why it reports a similar particle size distribution for coarse particles as it does for smoke and ambient background aerosol.

28 September 2021 in Building and Environment
Verified
Journal Article
Open access
JTJessica Tryner
Jessica Tryner
MPMollie Phillips
Mollie Phillips
CQCasey Quinn
Casey Quinn
GNGabe Neymark
Gabe Neymark
AWAnder Wilson
Ander Wilson
JVJohn Volckens
John Volckens
Americans spend most of their time indoors at home, but comprehensive characterization of in-home air pollution is limited by the cost and size of reference-quality monitors. We assembled small “Home Health Boxes” (HHBs) to measure indoor PM2.5, PM10, CO2, CO, NO2, and O3 concentrations using filter samplers and low-cost sensors. Nine HHBs were collocated with reference monitors in the kitchen of an occupied home in Fort Collins, Colorado, USA for 168 h while wildfire smoke impacted local air quality. When HHB data were interpreted using gas sensor manufacturers’ calibrations, HHBs and reference monitors (a) categorized the level of each gaseous pollutant similarly (as either low, elevated, or high relative to air quality standards) and (b) both indicated that gas cooking burners were the dominant source of CO and NO2 pollution; however, HHB and reference O3 data were not correlated. When HHB gas sensor data were interpreted using linear mixed calibration models derived via collocation with reference monitors, root-mean-square error decreased for CO2 (from 408 to 58 ppm), CO (645 to 572 ppb), NO2 (22 to 14 ppb), and O3 (21 to 7 ppb); additionally, correlation between HHB and reference O3 data improved (Pearson’s r increased from 0.02 to 0.75). Mean 168-h PM2.5 and PM10 concentrations derived from nine filter samples were 19.4 μg m−3 (6.1% relative standard deviation [RSD]) and 40.1 μg m−3 (7.6% RSD). The 168-h PM2.5 concentration was overestimated by PMS5003 sensors (median sensor/filter ratio = 1.7) and underestimated slightly by SPS30 sensors (median sensor/filter ratio = 0.91).