Robert Evans Neal II

Dr. Robert Evans Neal II

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
AVAtul Verma
Atul Verma
SASamuel J. Asivatham
Samuel J. Asivatham
TDThomas Deneke
Thomas Deneke
QCQuim Castellvi
Quim Castellvi
RIRobert Evans Neal II
Robert Evans Neal II
Pulsed electrical field (PEF) energy is a promising technique for catheter ablation of cardiac arrhythmias. In this article, the key aspects that need to be considered for safe and effective PEF delivery are reviewed, and their impact on clinical feasibility is discussed. The most important benefit of PEF appears to be the ability to kill cells through mechanisms that do not alter stromal proteins, sparing sensitive structures to improve safety, without sacrificing cardiomyocyte ablation efficacy. Many parameters affect PEF treatment outcomes, including pulse intensity, waveform shape, and number of pulses, as well as electrode configuration and geometry. These physical and electrical characteristics must be titrated carefully to balance target tissue effects with collateral implications (muscle contraction, temperature rise, risk of electrical arcing events). It is important to note that any combination of parameters affecting PEF needs to be tested for clinical efficacy and safety. Applying PEF clinically requires knowledge of the fundamentals of this technology to exploit its opportunities and generate viable, durable health improvements for patients.

6 January 2012 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
RIRobert Evans Neal II
Robert Evans Neal II
PGPaulo A. Garcia
Paulo A. Garcia
JRJohn L. Robertson
John L. Robertson
RDRafael V. Davalos
Rafael V. Davalos
Irreversible electroporation is a new technique to kill cells in targeted tissue, such as tumors, through a nonthermal mechanism using electric pulses to irrecoverably disrupt the cell membrane. Treatment effects relate to the tissue electric field distribution, which can be predicted with numerical modeling for therapy planning. Pulse effects will change the cell and tissue properties through thermal and electroporation (EP)-based processes. This investigation characterizes these changes by measuring the electrical conductivity and temperature of ex vivo renal porcine tissue within a single pulse and for a 200 pulse protocol. These changes are incorporated into an equivalent circuit model for cells and tissue with a variable EP-based resistance, providing a potential method to estimate conductivity as a function of electric field and pulse length for other tissues. Finally, a numerical model using a human kidney volumetric mesh evaluated how treatment predictions vary when EP- and temperature-based electrical conductivity changes are incorporated. We conclude that significant changes in predicted outcomes will occur when the experimental results are applied to the numerical model, where the direction and degree of change varies with the electric field considered.

29 July 2010 in The Journal of Membrane Biology
Verified
Journal Article
Closed access
PDF file
PGPaulo A. Garcia
Paulo A. Garcia
JRJohn H. Rossmeisl
John H. Rossmeisl
RIRobert Evans Neal II
Robert Evans Neal II
TEThomas L. Ellis
Thomas L. Ellis
JOJohn D. Olson
John D. Olson
Rafael DavalosRafael Davalos
Rafael Davalos

1 August 2004 in Cancer Research
Verified
Journal Article
Closed access
PDF file
LMLuka Milas
Luka Milas
KMKathryn A. Mason
Kathryn A. Mason
HAHisanori Ariga
Hisanori Ariga
NHNancy Hunter
Nancy Hunter
RIRobert Evans Neal II
Robert Evans Neal II
JWJohn K. Whisnant
John K. Whisnant
CpG oligodeoxynucleotides (ODNs) are synthetic DNA sequences containing unmethylated cytosine-guanine motifs with potent immunomodulatory effects. Via Toll-like receptor 9 agonism of dendritic cells and B cells, CpG ODNs induce cytokines, activate natural killer cells, and elicit vigorous T-cell responses that lead to significant antitumor effects, including improved efficacy of chemotherapeutic agents. On the basis of these properties of CpG ODNs, we tested whether they also could enhance tumor response to radiotherapy. Using an immunogenic mouse tumor, designated FSa, the response to radiotherapy was assayed by tumor growth delay and tumor cure rate (TCD50, radiation dose yielding 50% tumor cure rate). Treatments were initiated when established tumors were either 6 or 8 mm in diameter. CpG ODN as a single agent given s.c. peritumorally had little effect on tumor growth; however, it dramatically enhanced tumor growth delay in response to single-dose radiation by a factor of 2.58–2.65. CpG ODN also dramatically improved tumor radiocurability, reducing the TCD50 by a factor of 1.93, from 39.6 (36.1–43.1) Gy to 20.5 (14.3–25.7) Gy. The CpG ODN-induced enhancement of tumor radioresponse was diminished in tumor-bearing mice immunocompromised by sublethal whole-body radiation. Tumors treated with CpG ODN and radiation showed histologic changes characterized by increased necrosis, heavy infiltration by host inflammatory cells (lymphocytes and granulocytes), and reduced tumor cell density. These results show that CpG ODNs are potent enhancers of tumor radioresponse and as such have potential to improve clinical radiotherapy.

30 April 2011 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
PGPaulo A Garcia
Paulo A Garcia
John H. RossmeislJohn H. Rossmeisl
John H. Rossmeisl
RIRobert Evans Neal II
Robert Evans Neal II
TEThomas L Ellis
Thomas L Ellis
Rafael DavalosRafael Davalos
Rafael Davalos
Background: Irreversible electroporation (IRE) is a new minimally invasive technique to kill undesirable tissue in a non-thermal manner. In order to maximize the benefits from an IRE procedure, the pulse parameters and electrode configuration must be optimized to achieve complete coverage of the targeted tissue while preventing thermal damage due to excessive Joule heating. Methods: We developed numerical simulations of typical protocols based on a previously published computed tomographic (CT) guided in vivo procedure. These models were adapted to assess the effects of temperature, electroporation, pulse duration, and repetition rate on the volumes of tissue undergoing IRE alone or in superposition with thermal damage. Results: Nine different combinations of voltage and pulse frequency were investigated, five of which resulted in IRE alone while four produced IRE in superposition with thermal damage. Conclusions: The parametric study evaluated the influence of pulse frequency and applied voltage on treatment volumes, and refined a proposed method to delineate IRE from thermal damage. We confirm that determining an IRE treatment protocol requires incorporating all the physical effects of electroporation, and that these effects may have significant implications in treatment planning and outcome assessment. The goal of the manuscript is to provide the reader with the numerical methods to assess multiple-pulse electroporation treatment protocols in order to isolate IRE from thermal damage and capitalize on the benefits of a non-thermal mode of tissue ablation.

17 January 2014 in The Prostate
Verified
Journal Article
Closed access
PDF file
RIRobert Evans Neal II
Robert Evans Neal II
JMJeremy L Millar
Jeremy L Millar
HKHelen Kavnoudias
Helen Kavnoudias
PRPeter Royce
Peter Royce
FRFranklin Rosenfeldt
Franklin Rosenfeldt
KTKenneth R Thomson
Kenneth R Thomson