Daniela Filipa Campos Ferreira

Dr. Daniela Filipa Campos Ferreira

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2026 in Frontiers in Public Health
Verified
Journal Article
Open access
PDF file
DFD-Filipa Ferreira
D-Filipa Ferreira
AFAna-Carolina Fonseca
Ana-Carolina Fonseca
DFDaniela Filipa Campos Ferreira
Daniela Filipa Campos Ferreira
LPLuís Pinto-Coelho
Luís Pinto-Coelho
MRMatilde A. Rodrigues
Matilde A. Rodrigues
Introduction: This study evaluated the discriminative sensitivity of pupillometry, relative to subjective self-report measures, as an objective indicator of cognitive load during screen-based tasks performed under two workplace illuminance levels (300 and 500 lux). Inadequate workplace illuminance is associated with visual fatigue, stress, and impaired attention, yet its effect on cognitive strain during screen-based tasks remains underexplored through objective physiological indicators, particularly given the confounding influence of the pupillary light reflex (PLR) on pupillometric measures. Methods: Forty-eight working-age adults performed writing and working memory (N-back) tasks under both conditions in a controlled laboratory replicating office environments; pupil diameter was recorded continuously using Pupil Labs Core eye-tracking glasses, while the NASA-TLX and Visual Analog Scales (VAS) assessed subjective workload, stress, fatigue, and eye strain. Results: A direct comparison between illuminance conditions (Holm-corrected) revealed no significant effects of illuminance on pupillary parameters (|d| ≤ 0.19), but subjective workload increased with illuminance during the most demanding task ( d = 0.81). Both pupillometry and subjective measures detected significant pairwise differences between task demand levels consistently under both illuminance conditions (Kendall's W ranging from 0.29–0.35 for pupil diameter variance to 0.34–0.58 for NASA-TLX and VAS Stress). No significant differences were found for the writing task or the 2-back task across any measure. Discussion: The results indicate that pupillometry and subjective self-report measures are comparably sensitive to task demand, while only subjective workload was sensitive to illuminance, underscoring the value of combining objective and subjective indicators in occupational lighting research.