Humanoid biped robots are typically complex in design, having numerous Degrees-of-Freedom (DOF) due to the ambitious goal of mimicking the human gait. The paper proposes a new architecture for a biped robot with seven DOF per each leg and one DOF corresponding to the toe joint. Furthermore, this work presents close equations for the forward and inverse kinematics by dividing the walking gait into the Sagittal and Frontal planes. This paper explains the mathematical model of the dynamics equations for the legs into the Sagittal and Frontal planes by further applying the principle of Lagrangian dynamics. Finally, a control approach using a PD control law with gravity compensation was recurred in order to control the desired trajectories and finding the required torque by the joints. The paper contains several simulations and numerical examples to prove the analytical results, using SimMechanics of MATLAB toolbox and SolidWorks to verify the analytical results.
1 January 2015 in Mathematical Problems in Engineering
Current trends in Robotics aim to close the gap that separates technology and humans, bringing novel robotic devices in order to improve human performance. Although robotic exoskeletons represent a breakthrough in mobility enhancement, there are design challenges related to the forces exerted to the users’ joints that result in severe injuries. This occurs due to the fact that most of the current developments consider the joints as noninvariant rotational axes. This paper proposes the use of commercial vision systems in order to perform biomimetic joint design for robotic exoskeletons. This work proposes a kinematic model based on irregular shaped cams as the joint mechanism that emulates the bone-to-bone joints in the human body. The paper follows a geometric approach for determining the location of the instantaneous center of rotation in order to design the cam contours. Furthermore, the use of a commercial vision system is proposed as the main measurement tool due to its noninvasive feature and for allowing subjects under measurement to move freely. The application of this method resulted in relevant information about the displacements of the instantaneous center of rotation at the human knee joint.
Exoskeletons arise as the common ground between robotics and biomechanics, where rehabilitation is the main field in which these two disciplines find cohesion. One of the most relevant challenges in upper limb exoskeleton design relies in the high complexity of the human shoulder, where current devices implement elaborate systems only to emulate the drifting center of rotation of the shoulder joint. This paper proposes the use of 3D scanning vision technologies to ease the design process and its implementation on a variety of subjects, while a motion tracking system based on vision technologies is applied to assess the exoskeleton reachable workspace compared with an asymptomatic subject. Furthermore, the anatomic fitting index is proposed, which compares the anatomic workspace of the user with the exoskeleton workspace and provides insight into its features. This work proposes an exoskeleton architecture that considers the clavicle motion over the coronal plane whose workspace is determined by substituting the direct kinematics model with the dimensional parameters of the user. Simulations and numerical examples are used to validate the analytical results and to conciliate the experimental results provided by the vision tracking system.
28 November 2013 in Mathematical Problems in Engineering
This paper investigates the mobility of a family of fully translational parallel manipulators based on screw system analysis by identifying the common constraint and redundant constraints, providing a case study of this approach. The paper presents the branch motion-screws for the 3-RC-Y parallel manipulator, the 3-RCC-Y (or 3-RRC-Y) parallel manipulator, and a newly proposed 3-RC-T parallel manipulator. Then the paper determines the sets of platform constraint-screws for each of these three manipulators. The constraints exerted on the platforms of the 3-RCarchitectures and the 3-RCC-Y manipulators are analyzed using the screw system approach and have been identified as couples. A similarity has been identified with the axes of couples: they are perpendicular to theRjoint axes, but in the former the axes are coplanar with the base and in the latter the axes are perpendicular to the limb. The remaining couples act about the axis that is normal to the base. The motion-screw system and constraint-screw system analysis leads to the insightful understanding of the mobility of the platform that is then obtained by determining the reciprocal screws to the platform constraint screw sets, resulting in three independent instantaneous translational degrees-of-freedom. To validate the mobility analysis of the three parallel manipulators, the paper includes motion simulations which use a commercially available kinematics software.