Oxidative stress (OS) results in many disorders, of which degenerative musculoskeletal conditions are no exception. However, the interaction between OS and ligamentum flavum (LF) hypertrophy in lumbar spinal canal stenosis is not clearly understood. The first research question was whether OS was involved in LF hypertrophy, and the second was whether the antioxidant N-acetylcysteine (NAC) was effective on LF hypertrophy. In total, 47 LF samples were collected from patients with lumbar spinal disorders. The cross-sectional area of LF was measured on axial magnetic resonance imaging. Immunohistochemistry of 8-OHdG and TNF-α were conducted on human LF samples. A positive association was found between 8-OHdG or TNF-α expression and cross-sectional area of LF. Flow cytometry analysis showed that H2O2, buthionine sulfoximine, and TNF-α treatment significantly increased intracellular reactive oxygen species in primary LF cells. NAC inhibited the induction of LF hypertrophy markers by OS or TNF in a real-time reverse transcriptase polymerase chain reaction and enzyme-linked immunosorbent assay. Western blotting analysis indicated that p38, Erk, and p65 phosphorylation were involved in intracellular OS signaling in LF cells. In conclusion, our results indicated that OS could be a therapeutic target for LF hypertrophy. Although this study included no in vivo studies to examine the longitudinal efficacy of NAC on LF hypertrophy, NAC may have potential as a therapeutic agent against lumbar spinal canal stenosis.
Background and Objectives: Modic type 1 is known to be associated with lower back pain (LBP), but at present, a treatment has not been fully established. Meanwhile, platelet-rich plasma (PRP) has been used for tissue regeneration and repair in the clinical setting. There is no clinical PRP injection trial for the intervertebral disc of LBP patients with Modic type 1. Thus, this study aimed to verify PRP injection safety and efficacy in LBP patients with Modic type 1. As a preliminary experiment, two LBP cases with Modic type 1 are presented. Materials and Methods: PRP was administered intradiscally to two LBP patients with Modic type 1. PRP was obtained from the patients’ anticoagulated blood. Primary endpoints were physical condition, laboratory data, and X-ray for safety evaluation. Secondary endpoints were pain scores using the visual analog scale (VAS), the Oswestry Disability Index (ODI), and the Roland–Morris Disability Questionnaire (RDQ) to evaluate PRP efficacy. The observation period was 24 weeks after the PRP injection. In addition, changes in Modic type 1 using MRI were evaluated. Results: This study assessed two LBP patients with Modic type 1. There were no adverse events in physical condition, laboratory data, or lumbar X-rays after injection. Follow-up MRI showed a decrease of high signal intensity on T2WI compared to before PRP administration. The pain scores tended to improve after the injection. Conclusions: PRP injection into the intervertebral disc of LBP patients with Modic type 1 might be safe and effective. This analysis will be continued as a prospective study to establish the efficacy.
Treatment for lumbar spinal canal stenosis (LSCS) is mainly classified into conservative and surgical therapies. Among conservative therapies, pharmacological treatment is commonly prescribed for LSCS. Meanwhile, surgical treatment is the last option for LSCS. This study aimed to examine the impact of lumbar surgery on pharmacological treatment for patients with LSCS. Consecutive patients aged ≥ 40 years who underwent lumbar surgery for LSCS were identified. A total of 142 patients were retrospectively reviewed for preoperative and 6-month and 1-year postoperative LSCS medications. The results showed that the number of LSCS medications significantly decreased after lumbar surgery. The proportion of the patients taking non-steroidal anti-inflammatory drugs, pregabalin/mirogabalin, opioids, prostaglandin E1 analogs, and neurotropin was significantly decreased after lumbar surgery, but that of the patients taking mecobalamin, acetaminophen, and serotonin-noradrenalin reuptake inhibitors was not significantly changed. Additionally, around 15% of the participants showed an increase in LSCS medications even after lumbar surgery. Multivariable analysis revealed that individuals without improvements in walking ability (RR: 2.7, 95% CI: 1.3–5.9) or social life (RR: 2.3, 95% CI: 1.1–5.0) had a greater risk of a postoperative increase in LSCS medications. The study results may provide physicians with beneficial information on treatment for LSCS.
Background: The occurrence of ALL rupture during posterior correction of adult spinal deformity (ASD) was rare before the introduction of lateral lumbar interbody fusion (LLIF) but has become more frequent recently. It remains unclear whether this phenomenon is unique to LLIF-combined procedures or primarily related to enhanced corrective ability. Methods: The research method used in this study is finite element analysis (FEA). Using preoperative computed tomography images, LLIF cage (L group) or posterior lumbar interbody fusion (PLIF) cage (P group) were placed in the disc space with identical lordotic angles and distances from the anterior vertebral body edge for the same patients’ samples. Finite element simulations of corrective procedures were conducted. A spring simulating the ALL was introduced into the FEA, and the load on the ALL was evaluated with either LLIF or PLIF cage placement. Spring elongation directly measured the load on the ALL, while the location of the rotation center served as an indirect evaluation. Two different types of corrective procedures were created, one of which is mimicking ASD correction. For both procedures, the load to ALL was measured using abovementioned parameters when either LLIF cage (L group) or PLIF cage (P group) was used. The load to ALL was compared between L group and P group. Results: The degree of spring elongation during the simulation of a corrective procedure significantly decreased in the L group compared to the P group only in the model which is mimicking ASD correction (p = 0.006, Cohen’s d = 2.33, Power (1−β) = 0.956). The rotation center was significantly more posteriorly located in the P group than that in the L group in both models. These differences were more obvious in the model mimicking ASD correction (p = 0.0013, Cohen’s d = 2.00, Power (1−β) = 0.891). Conclusions: Our findings suggest that the use of a PLIF cage, which has a longer anterior–posterior cage length, caused the posterior edge of the cage to act as a pivot point. This configuration places greater leverage on the ALL, potentially leading to rupture during posterior correction procedures. This phenomenon, ALL rupture during posterior correction for ASD, is thought to be associated with increased corrective capabilities rather than being specific to the geometry of the LLIF cage.
BACKGROUND AND OBJECTIVES: Phase-contrast MRI is unstable and is not widely implemented in the imaging of Chiari malformation type I (CM-I) because of its low signal-to-noise ratio and the need for subsequent additional averaging. Time-spatial labeling inversion pulse MRI (T-SLIP MRI) is an emerging imaging modality with a high signal-to-noise ratio. This study is the first to examine cerebrospinal fluid (CSF) dynamics on the basis of velocity exclusively in patients with CM-I using T-SLIP MRI before and after posterior fossa decompression. METHODS: Eleven patients with CM-I underwent T-SLIP MRI before and/or after posterior fossa decompression. CSF dynamics were analyzed at 5 points around the craniovertebral junction. T-SLIP measurements included (1) targeted CSF labeling; (2) manual frame-by-frame annotation of the labeled CSF wave; (3) description of CSF flow in terms of wave functions calculated using computation software; and use of this function for (4) calculation of CSF velocity (rostral and caudal peak), total distance traveled by labeled CSF, and mean CSF velocity ( ). Differences between preoperative and postoperative peak velocity (rostral and caudal) and were assessed using paired t-test. RESULTS: Rostral and caudal peaks significantly increased at 2 of the 5 points (40%), whereas significantly increased at 4 points (80%), altogether covering all observation points with significant changes. CSF filling the syrinx through the syrinx wall from the spinal subarachnoid space and complex CSF flow at the dorsal craniovertebral junction were captured preoperatively and postoperatively, respectively. CONCLUSION: T-SLIP MRI data for patients with CM-I were successfully quantified on the basis of velocity. Tailor-made optimal decompression should be pursued based on both T-SLIP data with high accuracy and bibliographical craniometric data with surgical outcomes, which can now be easily and comprehensively analyzed using machine learning.
Background and Objectives: There are several advantages of using lateral lumbar interbody fusion (LLIF) for correction surgeries for adult spinal deformity (ASD); however, we currently have unresolved new issues, including occasional anterior longitudinal ligament (ALL) rupture during the posterior correction procedure. When LLIF was initially introduced, only less lordotic cages were available and ALL rupture was more frequently experienced compared with later periods when more lordotic cages were available. We performed finite element analysis (FEA) regarding the mechanism of ALL rupture during a posterior correction procedure. Methods: A spring (which mimics ALL) was introduced at the location of ALL in the FEA and an LLIF cage with two different lordotic angles, 6 and 12 degrees (6DC/12DC), was employed. To assess the extent of burden on the ALL, the extension length of the spring during the correction procedure was measured and the location of the rotation center was examined. Results: We observed a significantly higher degree of length extension of the spring during the correction procedure in the FEA model with 6DC compared with that of 12DC. We also observed that the location of the rotation center was shifted posteriorly in the FEA model with 6DC compared with that of 12DC. Conclusions: It is considered that the posterior and rostral edge of the less lordotic angle cage became a hinge, and the longer lever arm increased the burden on ALL as the principle of leverage. It is important to use an LLIF cage with a sufficient lordotic angle, that is compatible with the degree of posterior osteotomy in ASD correction.