Tetsuya Uchino

Dr. Tetsuya Uchino

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2010 in The Korean Journal of Pain
Verified
Journal Article
Open access
PDF file
TUTetsuya Uchino
Tetsuya Uchino
SHSatoshi Hagiwara
Satoshi Hagiwara
HIHideo Iwasaka
Hideo Iwasaka
KKKyosuke Kudo
Kyosuke Kudo
JTJunji Takatani
Junji Takatani
TNTakayuki Noguchi
Takayuki Noguchi
Uchino T, et al. Korean J Pain. 2010 Dec;23(4):247-253. https://doi.org/10.3344/kjp.2010.23.4.247

19 March 2022 in Journal of Anesthesia
Verified
Journal Article
Open access
PDF file
TUTetsuya Uchino
Tetsuya Uchino
MMMasahiro Miura
Masahiro Miura
SMShigekiyo Matsumoto
Shigekiyo Matsumoto
CSChihiro Shingu
Chihiro Shingu
TSToshitaka Shin
Toshitaka Shin
TKTakaaki Kitano
Takaaki Kitano
Purpose: The obturator nerve branches into the obturator canal; therefore, local anesthetic spread into the obturator canal predicts the success of the obturator nerve block (ONB). We compared three ONB techniques for the spread of local anesthetic mixed with contrast medium into the obturator canal. Methods: We performed the ONB using the classical pubic approach (PA), inguinal approach (IA), or ultrasound-guided methodologic approach (UMA) in 143 patients undergoing transurethral resection of bladder tumors. The obturator nerve course and branching patterns of the UMA group were examined using ultrasound imaging. After injecting a local anesthetic mixed with a contrast medium, we evaluated its spread into the obturator canal using fluoroscopic imaging. P < 0.05 indicated statistical significance. Results: Success rate of obturator canal enhancement was the greatest in the UMA group (84%; P < 0.001); the PA (42.6%; 20/47 patients) and IA (47.8%; 22/46 patients) groups did not differ significantly (P = 1.000). Both branches of the obturator nerve passed above the superior margin of the external obturator muscle (EOM), and the obturator canal was enhanced in 13 of 50 (26%) patients in the UMA group. The posterior branch of the obturator nerve passed between the superior and main fasciculi of the EOM in 37 of 50 patients (74%) in the UMA group; the obturator canal was enhanced in 29 of these 37 patients (78%). Conclusion: Local anesthetic spread into the obturator canal using the UMA was superior to that using the PA and IA. Both branches of the obturator nerve could be blocked using the UMA.

30 April 2016 in Journal of Anesthesia
Verified
Journal Article
Open access
PDF file
TUTetsuya Uchino
Tetsuya Uchino
MMMasahiro Miura
Masahiro Miura
YOYoshimasa Oyama
Yoshimasa Oyama
SMShigekiyo Matsumoto
Shigekiyo Matsumoto
CSChihiro Shingu
Chihiro Shingu
TKTakaaki Kitano
Takaaki Kitano
During epidural anesthesia, the catheter tip occasionally deviates from the epidural space into the intervertebral foramen, resulting in inadequate anesthesia.

1 June 2012 in Journal of Surgical Research
Verified
Journal Article
Closed access
KOKentaro Okuda
Kentaro Okuda
NTNaozumi Takeshima
Naozumi Takeshima
SHSatoshi Hagiwara
Satoshi Hagiwara
JTJunji Takatani
Junji Takatani
TUTetsuya Uchino
Tetsuya Uchino
TNTakayuki Noguchi
Takayuki Noguchi

13 July 2023 in The Journal of Vascular Access
Verified
Journal Article
Closed access
TUTetsuya Uchino
Tetsuya Uchino
MMMasahiro Miura
Masahiro Miura
SMShigekiyo Matsumoto
Shigekiyo Matsumoto
CSChihiro Shingu
Chihiro Shingu
TKTakaaki Kitano
Takaaki Kitano
Background: The superficial radial artery (SRA) is a rare congenital anomaly in the forearm. However, it can be detected incidentally via trauma, intraoperative findings, angiography, or ultrasonography. In addition, intra-arterial infusion of intravenous medications and difficulties in radial artery catheterization may occur in cases of the SRA. Methods: Between December 2016 and July 2020, anomalous branches of radial arteries were found incidentally in nine patients at the preoperative visit and identified during ultrasound-guided radial artery puncture in 21 patients when radial artery catheterization using the palpation method proved difficult. Ultrasound examinations were performed for diagnosis and evaluation of these 30 patients. Results: All anomalous branches of the radial artery were SRAs; 11 (37%), 13 (43%), 6 (20%) were present on the right side, on the left side, and bilaterally, respectively. All SRAs ran close to the cephalic vein. The vascular diameters of the radial arteries were the smallest in the radial artery distal to the SRA bifurcation (followed by in the SRA) and the largest in the radial artery proximal to the bifurcation ( p < .001). In two cases, color Doppler study revealed that both the blood flow and color Doppler signal of the SRA disappeared with compression of the radial artery proximal to the SRA bifurcation. Conclusions: Because the SRA runs very close to the cephalic vein, a tourniquet applied to the arm may easily lead to intravenous catheter misplacement into the SRA. In addition, the small radial artery distal to the SRA bifurcation causes difficulty in radial artery catheterization. Furthermore, SRA cases may have falsely normal Allen’s test results. Therefore, the authors recommend that the SRA must be identified before vascular puncture for safe vascular catheterization in the forearm.

3 May 2025 in The Journal of Vascular Access
Verified
Journal Article
Closed access
SNShoko Nakamura
Shoko Nakamura
TUTetsuya Uchino
Tetsuya Uchino
SMShigekiyo Matsumoto
Shigekiyo Matsumoto
Radial artery catheterization is commonly performed using the pulse palpation method. However, anatomical variations, such as the persistent median artery—an embryonic structure that may persist into adulthood—can complicate this procedure. A 47-year-old female scheduled for laparoscopic surgery required radial artery catheterization for hemodynamic monitoring. Multiple attempts to place a 22-gauge catheter in the left radial artery were unsuccessful. During the procedure, a pulsating vessel was identified on the ulnar side of the radial artery. Vascular visualization devices revealed the presence of a persistent median artery, accompanied by the median nerve. Subsequently, real-time ultrasound guidance facilitated successful radial artery catheterization. Anatomical variations, such as the persistent median artery, can complicate radial artery catheterization and are not easily identified through pulse palpation alone. The use of vascular visualization devices is recommended to identify and navigate such variations, ensuring accurate catheter placement.