Callum Fisk

Mr. Callum Fisk

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

27 August 2024 in Fuel
Verified
Journal Article
Open access
YLYufeng Lai
Yufeng Lai
XLXuanqi Liu
Xuanqi Liu
MPMuyi Pan
Muyi Pan
MDMatthew Davies
Matthew Davies
CFCallum Fisk
Callum Fisk
JWJon Willlmott
Jon Willlmott

12 March 2025 in Fuel
Verified
Journal Article
Closed access
YLYufeng Lai
Yufeng Lai
XLXuanqi Liu
Xuanqi Liu
MDMatthew Davies
Matthew Davies
CFCallum Fisk
Callum Fisk
YWYunbai Wang
Yunbai Wang
JWJon Willlmott
Jon Willlmott

30 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Emilios LeonidasEmilios Leonidas
Emilios Leonidas
MHMatthew Hobbs
Matthew Hobbs
SASabino Ayvar-Soberanis
Sabino Ayvar-Soberanis
HLHatim Laalej
Hatim Laalej
CFCallum Fisk
Callum Fisk
JWJon Willlmott
Jon Willlmott
Infrared radiation thermometers (IRTs) overcome many of the limitations of thermocouples, particularly responsiveness and calibration drift. The main challenge with radiation thermometry is the fast and reliable measurement of temperatures close to room temperature. A new IRT which is sensitive to wavelengths between 3 μm and 11 μm was developed and tested in a laboratory setting. It is based on an uncooled indium arsenide antimony (InAsSb) photodiode, a transimpedance amplifier, and a silver halogenide fibre optic cable transmissive in the mid- to long-wave infrared region. The prototype IRT was capable of measuring temperatures between 35 °C and 100 °C at an integration time of 5 ms and a temperature range between 40 °C and 100 °C at an integration time of 1 ms, with a root mean square (RMS) noise level of less than 0.5 °C. The thermometer was calibrated against Planck’s law using a five-point calibration, leading to a measurement uncertainty within ±1.5 °C over the aforementioned temperature range. The thermometer was tested against a thermocouple during drilling operations of polyether ether ketone (PEEK) plastic to measure the temperature of the drill bit during the material removal process. Future versions of the thermometer are intended to be used as a thermocouple replacement in high-speed, near-ambient temperature measurement applications, such as electric motor condition monitoring; battery protection; and machining of polymers and composite materials, such as carbon-fibre-reinforced plastic (CFRP).

21 October 2025 in Materials
Verified
Journal Article
Open access
PDF file
THThomas Michael Fletcher Hutchinson
Thomas Michael Fletcher Hutchinson
MDMatthew Davies
Matthew Davies
CFCallum Fisk
Callum Fisk
HZHazem Zied
Hazem Zied
JWJon Willlmott
Jon Willlmott
MHMatthew Hobbs
Matthew Hobbs
This work presents a bespoke, non-contact, and low-cost Phosphor Thermometry (PT) technique for the measurement of material absorptivity. The approach circumvents the challenges associated with traditional and intrusive calorimetric techniques, which require secure contact with the sample substrate. A thermographic phosphor (TP), Manganese-activated Magnesium Fluorogermanate (MFG), was used as a two-colour thermometer utilising the peak intensity ratio technique, enabling an empirical temperature measurement of a given Material Under Test (MUT). The system was calibrated to temperature across a dynamic range of 20°C to 140°C and subsequently assessed in terms of noise and relative sensitivity. A mathematical model describing the thermal behaviour of the samples was subsequently developed and used to infer the absorptivity value of the MUTs. Two paints, Black 3.0® and Avian-B500®, with known but contrasting absorptivities, were analysed, resulting in measured absorptivity values of 0.9385 and 0.0651 within a range of 0.0081 and 0.0127 for the two paints, respectively. Subsequent mixtures of both paints, with inherent unknown absorptivities, provided resolvable and incremental steps between the two extremities. Further measurements at specific narrow-band wavelengths of 600nm and 1550nm of Black 3.0® were performed, yielding median absorptivity values of 0.9598 and 0.9172 within a range of 0.0168 and 0.0396, respectively, therefore demonstrating the technique for the measurement of material absorptivity at discrete wavelengths. The potential of a non-contact calorimetric PT technique could provide a scalable, non-intrusive, and low-cost solution for measuring the wavelength-dependent absorptivity values of materials that are used across engineering and research fields.

18 March 2025
Verified
Conference Paper
Open access
MSMary Stuart
Mary Stuart
MDMatthew Davies
Matthew Davies
CFCallum Fisk
Callum Fisk
EAElizabeth Allen
Elizabeth Allen
Andrew SoleAndrew Sole
Andrew Sole
JWJon Willmott
Jon Willmott
Hyperspectral imaging is a valuable analytical technique with significant benefits for environmental monitoring. However, the application of these technologies remains limited, largely by the cost and bulk associated with available instrumentation. This results in a lack of high-resolution data from more challenging and extreme environmental settings, limiting our knowledge and understanding of the effects of climate change in these regions. Here we challenge these limitations through the application of a low-cost, smartphone-based hyperspectral imaging instrument to measurement and monitoring activities at the Greenland Ice Sheet. Datasets are captured across a variety of supraglacial and proglacial locations covering visible and near infrared wavelengths. Our results are comparable to the existing literature, despite being captured with instrumentation costing over an order of magnitude less than currently available commercial technologies. Practicalities for field deployment are also explored, demonstrating our approach to be a valuable addition to the research field with the potential to improve the availability of datasets from across the cryosphere, unlocking a wealth of data collection opportunities that were hitherto infeasible.