Changyin  Zhao Zhao

Dr. Changyin Zhao Zhao

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2023 in Processes
Verified
Journal Article
Open access
PDF file
ZXZhe Xu
Zhe Xu
XNXin Ning
Xin Ning
RLRui Li
Rui Li
XWXiuying Wan
Xiuying Wan
CZChangyin Zhao Zhao
Changyin Zhao Zhao
A design indicators prediction model using the Bell-Delaware method for a shell-and-tube heat exchanger with segmental baffles (STHX-SB) is constructed and validated by experiment. The average errors of heat transfer capacity and tube-side pressure drop are 8.52% and 7.92%, respectively, and the predicted weight is the same as the weight obtained by Solidworks commercial software, which indicates the model’s reliability. Parametric influences of the outside diameter of the heat dissipation tube, clearance between heat dissipation tubes, heat dissipation tube length, and tube bundle bypass flow clearance on heat transfer capacity per tube-side pressure drop and heat transfer capacity per weight are studied, and it indicates that whether the interaction between factors is considered or not, both heat transfer capacity per tube-side pressure drop and heat transfer capacity per weight are the most sensitive to outside diameter of heat dissipation tube and the least sensitive to heat dissipation tube length based on the Sobol’ method. To avoid falling into local optima due to algorithm convergence being too fast and to improve the reliability of solving complex optimization problems, Non-Dominated Sorted Genetic Algorithm II (NSGAII) and Multi-Objective Particle Swarm Optimization (MOPSO) embedded grouping cooperative coevolution (NSGAII-MOPSO-GCC) is proposed to optimize the studied four configuration parameters to maximize heat transfer capacity per tube-side pressure drop and heat transfer capacity per weight for STHX-SB, simultaneously. Compared with the original structure, heat transfer capacity per tube-side pressure drop and heat transfer capacity per weight of the chosen solutions separately increased by 57.66% and 4.63%, averagely, and in the optimization comparison of NSGAII, MOPSO, and NSGAII-MOPSO-GCC, NSGAII-MOPSO-GCC has the best performance, which shows that the proposed method is effective and feasible and can supply beneficial solutions and valuable guidance for heat exchanger design and improvement.

17 September 2024 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
ZXZhe Xu
Zhe Xu
ZYZongling Yu
Zongling Yu
XNXin Ning
Xin Ning
XWXiuying Wan
Xiuying Wan
ZQZhipeng Qu
Zhipeng Qu
CZChangyin Zhao Zhao
Changyin Zhao Zhao

25 March 2025 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
ZXZhe Xu
Zhe Xu
CZChangyin Zhao Zhao
Changyin Zhao Zhao
XNXin Ning
Xin Ning
MQMengyao Qin
Mengyao Qin
ZZZhen Zhang
Zhen Zhang
FNFuquan Nie
Fuquan Nie

17 February 2025 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
ZXZhe Xu
Zhe Xu
ZYZongling Yu
Zongling Yu
XNXin Ning
Xin Ning
CZChangyin Zhao Zhao
Changyin Zhao Zhao
FNFuquan Nie
Fuquan Nie

23 June 2025 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
ZXZhe Xu
Zhe Xu
ZYZongling Yu
Zongling Yu
XNXin Ning
Xin Ning
CZChangyin Zhao Zhao
Changyin Zhao Zhao
ZZZhihua Zhu
Zhihua Zhu
ZFZhibin Feng
Zhibin Feng

12 November 2025 in Energies
Verified
Journal Article
Open access
PDF file
CZChangyin Zhao Zhao
Changyin Zhao Zhao
ZXZhe Xu
Zhe Xu
XNXin Ning
Xin Ning
MWMin Wang
Min Wang
PJPengyu Jiang
Pengyu Jiang
The method of effectiveness-number of heat transfer units (ε-NTU) is adopted to establish a design indicator prediction model for plate fin precooler (PFP), and experimental verification is conducted. The average error between the experimental heat transfer capacity and the calculated heat transfer capacity is 4.65%, and the predicted mass matches the mass computed via the commercial software SolidWorks 2020. This outcome confirms the model’s reliability. An investigation is conducted into the influences of parametric factors, including hot stream flow length, cold stream flow length, hot side number of layers, and hot side fin pitch on the heat transfer capacity and mass of the PFP. To realize the maximization of heat transfer capacity and the minimization of mass, optimization is performed on the four sensitive configuration parameters by leveraging the multi-objective grey wolf optimizer (MOGWO). This optimization can significantly reduce the mass while ensuring the stability of the heat transfer capacity. Three classes of optimal configurations were derived from Pareto optimal points. Compared to the original structure, the selected schemes exhibit an average 2.95% rise in heat transfer capacity and a 10.7% reduction in mass. These findings show that the optimization method proposed in this study is effective and provides valuable guidance for precooler design.